Introduction
This manual provides essential instructions for the safe installation, operation, and maintenance of your APC AP7922 32A 230V Switched Rack PDU. The AP7922 is a rack-mountable power distribution unit designed to provide advanced power control and monitoring capabilities for IT equipment in data centers and server rooms. It features AC 230V input, Ethernet 10/100 connectivity, and 16 output connectors, all within a 2U, 19-inch form factor.
Маанилүү коопсуздук маалыматы
Please read and understand all safety instructions before installing or operating this equipment. Failure to follow these instructions could result in electric shock, fire, or serious injury.
- Бул аппарат имараттын ичинде гана колдонууга арналган.
- Connect the PDU to a properly grounded power source.
- Do not attempt to open or service the PDU. Refer all servicing to qualified personnel.
- Ensure the total current draw of connected equipment does not exceed the PDU's maximum current rating (32 Ampс).
- Тейлөө же орнотуу процедураларын аткаруудан мурун электр кубатын өчүрүңүз.
Пакеттин мазмуну
Таңгактан чыгарганда бардык буюмдар бар экенин текшериңиз:
- APC AP7922 Switched Rack PDU
- Орнотуу боюнча колдонмо
- Стойкага орнотулган кронштейндер
- Serial configuration cable
- Документтик CD
Продукт өзгөчөлүктөрү
The APC AP7922 Switched Rack PDU offers the following key features:
- Которуу розеткалары: Remotely control power to individual outlets for power cycling, delayed sequencing, and load shedding.
- Тармакты башкаруу: Full-featured network management interface via Ethernet 10/100 for remote monitoring and control.
- Учурдагы мониторинг: Monitor the aggregate current draw per PDU to prevent circuit overloads.
- Стойкага орнотулган дизайн: Occupies 2U of rack space, compatible with standard 19-inch racks.
- Чыгуу туташтыргычтары: Equipped with 16 C13 output connectors.
- Киргизүү көлөмүtage: Supports AC 230V input.

Сүрөт: алдыңкы view of the APC AP7922 Switched Rack PDU, showing the 16 C13 outlets and network interface.
Орнотуу нускамалары
1. Rack Монтаждоо
- Identify two available 2U spaces in your standard 19-inch equipment rack.
- Attach the provided rack-mounting brackets to the PDU using the screws supplied.
- Secure the PDU into the rack using appropriate rack screws. Ensure it is firmly seated and level.
2. Power Connection
- Connect the PDU's input power cord to a dedicated 230V, 32A power source. Ensure the power source is properly grounded.
- Do not overload the circuit. Verify that the total load of connected devices will not exceed 32 Amps.
3. Тармакка кошулуу
- Connect a standard Ethernet cable from the PDU's network port to your network switch or router.
- The PDU will obtain an IP address via DHCP by default. Refer to the full user manual for static IP configuration.
Иштөө нускамалары
Powering On/Off Connected Devices
Once the PDU is powered and connected to the network, you can manage its outlets remotely.
- Access the PDU's web анын IP дарегин киргизүү менен интерфейс web браузер.
- Log in using the default credentials (refer to the full manual for details).
- Navigate to the outlet control section. From here, you can individually switch on, switch off, or cycle power to each of the 16 C13 outlets.
Monitoring Current Draw
The web interface also provides real-time monitoring of the aggregate current draw. This allows you to ensure that the PDU and its connected circuit are not overloaded.
Техникалык тейлөө
- Тазалоо: Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents.
- Программалык камсыздоонун жаңыртуулары: APC текшериңиз website for available firmware updates to ensure optimal performance and security. Follow the instructions provided with the firmware package for safe updating.
- Кабелдик башкаруу: Ensure all power and network cables are neatly routed and secured to prevent accidental disconnections or damage.
Проблемаларды чечүү
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| PDU does not power on. | Киргизүү кубаты жок; автоматтык өчүргүч иштебей калган. | Verify the power cord is securely connected. Check the building's circuit breaker for the PDU's power source. |
| Кирүү мүмкүн эмес web интерфейс. | Incorrect IP address; network connectivity issue; PDU not powered. | Ensure the PDU is powered on. Verify network cable connection. Confirm the correct IP address. Check network settings. |
| Outlets do not switch. | Software issue; PDU fault. | Try restarting the PDU. If the issue persists, contact technical support. |
| Ашыкча жүк сигналы. | Total current draw exceeds PDU rating. | Disconnect non-essential equipment to reduce the load. Redistribute equipment across multiple PDUs if necessary. |
Техникалык мүнөздөмөлөр
| Өзгөчөлүк | Деталь |
|---|---|
| Модель номери | AP7922 |
| Бренд | Schneider Electric компаниясынын APC |
| Форма фактору | 2U Rack-mountable, 19-inch |
| Киргизүү көлөмүtage | 230 Вольт |
| Киргизүү агымы | 32 Amps |
| Output Voltage | 230 Вольт |
| Output Current | 32 Ampс (Макс) |
| Соода түйүндөрүнүн саны | 16 |
| Туташтыргыч түрү | C13 |
| Тармак интерфейси | Ethernet 10/100 |
| Ватtage | 7360 ватт |
| Өлчөмдөрү (H x W x D) | 4.49 x 17.52 x 3.5 дюйм |
| Салмагы | 0.7 килограмм |
| Материал | Металл |
| Түс | Кара |
Кепилдик жана колдоо
Кепилдик маалымат
APC өнүмдөрү, адатта, өндүрүүчүнүн стандарттуу кепилдиги менен келет. Сураныч, өнүмүңүз менен кошо берилген кепилдик картасын караңыз же расмий APC дүкөнүнө баш багыңыз. website for detailed warranty terms and conditions specific to the AP7922 model.
Техникалык колдоо
For technical assistance, troubleshooting, or to report issues, please contact APC customer support. You can find contact information and additional resources on the official Schneider Electric webсайт: