Empire VFSR30NAT

Empire White Mountain Hearth VFSR30NAT 30 дюймдук желдеткичсиз жаратылыш газы менен капталдагы глазурь күйгүзгүчтүн колдонуу боюнча колдонмосу

Model: VFSR30NAT

1. Продукт бүтүп калдыview

The Empire White Mountain Hearth VFSR30NAT is a 30-inch vent-free slope glaze burner designed for use with natural gas. This burner system incorporates ceramic beads to enhance flame appearance, creating a realistic fire effect. It features a Millivolt Safety Valve with an integrated on/off switch for user control and is remote-ready for convenience. The burner is capable of producing up to 38,000 BTU and requires an Empire "LS" log set of the same size for proper operation.

Негизги өзгөчөлүктөрү:

  • Internal Ceramic Beads: Designed to tumble gas, creating a dynamic and realistic flame pattern.
  • Millivolt Valve: Includes an on/off switch for direct control of the burner.
  • Күйүүчү май түрү: Operates on Natural Gas.
  • Өлчөмү: 30-inch burner, compatible with Empire "LS" log sets of matching size.
  • Жылуулук чыгаруу: Up to 38,000 British Thermal Units (BTU).
Empire White Mountain Hearth VFSR30NAT burner with ceramic logs and active flame

1-сүрөт: The Empire White Mountain Hearth VFSR30NAT 30-inch vent-free natural gas slope glaze burner shown with an Empire "LS" log set and active flames, illustrating its realistic fire appearance.

2. Коопсуздук маалыматы

ЭСКЕРТҮҮ: Туура эмес орнотуу, тууралоо, өзгөртүү, тейлөө же тейлөө жаракатка же мүлккө зыян келтириши мүмкүн. Бул жабдууну орнотуудан же тейлөөдөн мурун орнотуу, иштетүү жана тейлөө нускамаларын кылдат окуп чыгыңыз.

  • This appliance is for use with Жаратылыш газы гана. Do not attempt to use with other fuel types.
  • Vent-free gas appliances produce carbon monoxide. Ensure adequate ventilation and never operate in unventilated spaces.
  • Always ensure proper clearances to combustible materials as specified in the full installation manual.
  • Орнотуу жана тейлөө квалификациялуу орнотуучу, тейлөө агенттиги же газ берүүчү тарабынан аткарылышы керек.
  • Сунуш 65 Эскертүү: Бул продукт сизди химиялык заттарга, анын ичинде көмүртек кычкышына дуушар кылышы мүмкүн, бул Калифорния штатында тубаса кемтиктерге же башка репродуктивдүү зыянга алып келиши белгилүү. Көбүрөөк маалымат алуу үчүн өтүңүз www.P65Warnings.ca.gov.
  • Кийимдерди же башка күйүүчү материалдарды шаймандын үстүнө же жанына койбоңуз.
  • Keep children and pets away from the appliance when it is in operation.
Natural Gas icon

2-сүрөт: This icon indicates that the burner is designed for Natural Gas fuel only. Verify your gas supply type before installation.

3. Пакеттин мазмуну

Upon unpacking, verify that all components are present and undamaged. If any parts are missing or damaged, do not attempt to install or operate the burner. Contact your dealer or the manufacturer immediately.

  • VFSR30NAT 30-Inch Vent-Free Slope Glaze Burner Assembly
  • Millivolt Safety Valve (pre-installed)
  • Instruction Manual
  • Монтаждоочу жабдык (эгер бар болсо)

Эскертүү: Log sets are sold separately and are required for proper operation and aesthetic completion. Ensure you have an Empire "LS" log set of matching size (30-inch) for this burner.

4. Орнотуу жана орнотуу

Installation of this vent-free gas burner must comply with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. It is strongly recommended that installation be performed by a qualified professional.

4.1 Fireplace Requirements

This burner is designed for installation in a masonry or listed factory-built fireplace. Ensure your fireplace meets the minimum dimensions required for safe operation. Refer to the table below for non-Empire minimum firebox dimensions.

Fireplace dimensions diagram and table for Vent-Free Slope Glaze Burners

3-сүрөт: Diagram illustrating key fireplace dimensions (Front width opening, Rear width, Depth, Height) and a table detailing minimum non-Empire firebox dimensions for various Vent-Free Slope Glaze Burner models, including the VFSR-30.

4.2 Газга кошулуу

Connect the burner to your natural gas supply line. All gas connections must be leak-tested before operating the appliance. Use only approved gas piping and fittings.

4.3 Millivolt Wiring

The Millivolt Safety Valve system requires specific wiring for operation, including connections for the thermopile, thermocouple, and optional remote control or wall switch. Refer to the wiring diagram for correct connections.

Millivolt wiring diagram for gas valve, thermopile, thermocouple, and optional remote/wall switch

4-сүрөт: Detailed wiring diagram for the Millivolt system, showing connections for the gas valve, thermopile, thermocouple, and optional remote control receiver or wall switch. Ensure all wiring is performed by a qualified technician.

4.4 Log Set Placement

Carefully place the Empire "LS" log set onto the burner according to the log set's specific instructions. Incorrect log placement can affect flame appearance and burner performance, and may lead to carbon monoxide production.

5. Иштөө нускамалары

5.1 Lighting the Pilot

  1. Ensure the gas supply to the appliance is turned on.
  2. Locate the control knob on the Millivolt Safety Valve.
  3. Push the control knob in and turn it to the "PILOT" position.
  4. While holding the knob in, press the igniter button repeatedly until the pilot flame lights.
  5. Continue to hold the control knob in for approximately 60 seconds after the pilot lights to allow the thermocouple to heat up.
  6. Release the control knob. If the pilot extinguishes, repeat the lighting procedure.
  7. Once the pilot is lit, turn the control knob to the "ON" position.

5.2 Turning On the Main Burner

After the pilot is lit and the control knob is in the "ON" position:

  • Кол менен иштөө: Use the on/off switch located on the Millivolt Safety Valve to turn the main burner on or off.
  • Алыстан иштөө (кошумча): If a remote control receiver is installed, use the remote control to activate the main burner. Refer to your remote control's instructions for pairing and operation.

5.3 Turning Off the Burner

  • To turn off the main burner, use the on/off switch or remote control.
  • To turn off the pilot, turn the control knob on the Millivolt Safety Valve to the "OFF" position.
  • For extended periods of non-use, it is recommended to turn off the gas supply to the appliance.

6. Техникалык тейлөө

Regular maintenance ensures safe and efficient operation of your burner. All maintenance should be performed by a qualified service technician.

  • Жылдык текшерүү: Have the burner and gas connections inspected annually by a qualified service technician. This includes checking for gas leaks, proper pilot and main burner operation, and condition of the ceramic beads and log set.
  • Тазалоо: Keep the burner area free from dust, lint, and debris. Use a soft brush or vacuum cleaner to gently clean the burner ports and pilot assembly. Do not use abrasive cleaners.
  • Журнал топтому: Inspect the log set periodically for cracks or deterioration. Replace any damaged logs to maintain proper flame pattern and safety.
  • Ceramic Beads: Ensure the ceramic beads are properly positioned over the burner. If they become dislodged, carefully reposition them according to the original setup.

7. Кыйынчылыктарды

If you experience issues with your burner, consult the following common troubleshooting steps. For problems not listed or if issues persist, contact a qualified service technician.

КөйгөйМүмкүн себепЧечим
Учкуч күйбөйт.No gas supply; air in gas line; faulty igniter; pilot orifice clogged; thermocouple/thermopile issue.Ensure gas supply is on. Bleed air from line. Check igniter spark. Clean pilot orifice. Inspect thermocouple/thermopile connections.
Pilot lights but will not stay lit.Thermocouple not heating sufficiently; faulty thermocouple/thermopile; control knob not held long enough.Hold control knob in for 60 seconds. Ensure pilot flame engulfs thermocouple. Replace faulty thermocouple/thermopile.
Негизги от жагылбайт.Pilot not lit; control knob not in "ON" position; main burner orifice clogged; faulty Millivolt valve; remote control issue.Light pilot. Turn control knob to "ON". Clean burner orifice. Check Millivolt valve. Check remote battery/pairing.
Poor flame appearance.Incorrect log placement; burner ports clogged; low gas pressure.Adjust log placement per log set instructions. Clean burner ports. Verify gas pressure with a qualified technician.

8. Техникалык шарттар

АтрибутДеталь
Модель атыАк тоо очогу
Модель номериVFSR30NAT
БрендИмперия
Отургычтын өлчөмү30 дюйм
Күйүүчү май түрүЖаратылыш газы
Вентиляция түрүVent-Free
Жылуулук чыгаруу38,000 Британ жылуулук бирдиги (BTU)
Power SourceГаз менен иштейт
Күйүүчү түрүКерамикалык
МатериалКерамикалык
Продукциянын өлчөмдөрү (болжол менен)17.5"D x 33"W x 9.25"H
Элемент Салмагы30 фунт
Орнотуу түрүFreestanding (within a fireplace)
Өзгөчө өзгөчөлүкCordless (Millivolt system)
UPC720968265630

9. Кепилдик жана колдоо

9.1 Кепилдик маалыматы

This Empire White Mountain Hearth burner comes with a Чектелген Кепилдик. Specific terms and conditions of the warranty, including coverage duration and what is covered, are typically provided with the product packaging or can be obtained from the manufacturer. Please retain your proof of purchase for warranty claims.

9.2 Кардарларды колдоо

For technical assistance, parts, or warranty inquiries, please contact Empire customer support. Refer to the contact information provided in your product packaging or visit the official Empire webакыркы колдоо маалымат үчүн сайт.

When contacting support, please have your model number (VFSR30NAT) and proof of purchase readily available.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.