Diehl CECOMINOD014742

Diehl 24 hr Spa Timer Instruction Manual

Model: TA4071 (CECOMINOD014742) | Brand: Diehl

Introduction

The Diehl 800 series electromechanical time clock, model TA4071, is a robust 24-hour timer designed for various applications, including bath, whirlpool, spa, and hot tub controls. This 120V, 15-amp panel mount timer features a Single Pole Single Throw (SPST) configuration with four terminal tabs for electrical connections. Its durable design ensures reliable operation for managing electrical loads on a daily cycle.

Коопсуздук маалыматы

  • Always disconnect power at the circuit breaker or fuse box before installing, servicing, or removing the timer.
  • Installation should be performed by a qualified electrician or a knowledgeable individual familiar with electrical wiring and local codes.
  • Таймердин үнүн текшериңизtagд жана amperage ratings match the circuit and load requirements. This timer is rated for 120V, 15A.
  • Таймердин максималдуу электрдик кубаттуулугунан ашпаңыз.
  • Protect the timer from moisture and extreme temperatures.
  • Электр энергиясын калыбына келтирүүдөн мурун, бардык туташуулардын бекем жана жакшы изоляцияланганын текшериңиз.

Орнотуу жана орнотуу

The Diehl TA4071 is designed for panel mounting. Follow these steps for proper installation:

  1. Электр энергиясын өчүрүү: Before beginning any installation, ensure that the main power supply to the circuit where the timer will be installed is turned off at the circuit breaker or fuse box.
  2. Монтаждоо: Secure the timer to a suitable panel or enclosure using appropriate fasteners. The timer is designed for panel mount applications.
  3. Зымдар: This timer features four terminal tabs located on the bottom for electrical connections. As an SPST (Single Pole Single Throw) timer, it controls a single circuit. Connect the 120V power supply and the load wires to the designated terminals. Refer to the wiring diagram provided with your specific application or consult a qualified electrician.
  4. Текшерүү: Double-check all wiring connections for tightness and correctness. Ensure no bare wires are exposed.
  5. Күчтү калыбына келтирүү: Орнотуу аяктагандан жана текшерилгенден кийин, чынжырга электр кубатын кайтарыңыз.
Diehl 24 hr Spa Timer, showing the black dial with white numbers and red outer ring, and the four terminal tabs at the bottom.

Figure 1: Diehl 24 hr Spa Timer (Model TA4071). This image displays the timer's front face with its 24-hour dial, indicating time settings and rotation arrows. The red outer ring and the four terminal tabs at the base are also visible, highlighting its panel mount design and electrical connection points.

Иштөө нускамалары

The Diehl 24 hr Spa Timer operates on a daily cycle. To set the timer:

  1. Учурдагы убакытты коюу: Rotate the timer dial clockwise until the current time aligns with the fixed pointer or marker on the timer's housing. The dial features a 24-hour scale.
  2. Set ON/OFF Times: The timer typically uses small, movable pins or segments around the outer edge of the dial to set the ON and OFF times. Push the segments outwards for the periods you want the connected device to be ON, and leave them inwards for the OFF periods. Consult the specific instructions for your timer's pin mechanism if different.
  3. Операцияга байкоо жүргүзүү: The timer will automatically cycle through the set ON/OFF periods every 24 hours. You should hear an audible "click" when the internal switch actuates at the set ON and OFF times.

The orange colored bezel behind the timer dial is a visual indicator and part of the timer's design.

Техникалык тейлөө

The Diehl 24 hr Spa Timer is designed for minimal maintenance. However, periodic checks can ensure its longevity and proper function:

  • Тазалоо: Gently wipe the exterior of the timer with a dry, soft cloth to remove dust and debris. Do not use liquid cleaners or solvents.
  • Туташуу текшерүү: Periodically, with power disconnected, inspect the terminal connections to ensure they remain tight and free from corrosion.
  • Экологиялык шарттар: Ensure the timer is not exposed to excessive moisture, dust, or extreme temperatures, which can affect its performance and lifespan.

Проблемаларды чечүү

КөйгөйМүмкүн себепЧечим
Timer not operating (dial not rotating)No power to the timer; internal motor failure.Check circuit breaker/fuse. Verify wiring connections. If power is present and dial still doesn't move, the timer may need replacement.
Connected device not turning ON/OFF at set timesIncorrect setting of ON/OFF pins/segments; internal switch failure.Review operating instructions to ensure pins/segments are correctly set. Listen for an audible "click" when the dial passes the set times; if no click, the internal switch may be faulty and require timer replacement.
Timer makes unusual noisesWorn internal gears or motor.While some mechanical timers produce a faint hum, loud or grinding noises indicate wear. Consider replacing the timer if noises are excessive or performance is affected.

Техникалык шарттар

  • Бренд: Diehl
  • Модель номери: TA4071 (Item model number: CECOMINOD014742)
  • Тtage: 120 вольт
  • Которуу стили: SPST (бир уюлдук бир ыргытуу)
  • Монтаж түрү: Панел орнотуу
  • Элемент Салмагы: 1.6 унция
  • Продукциянын өлчөмдөрү: 1 x 3 x 3 дюйм
  • UPC: 702811354609
  • Өндүрүүчү: Diehl

Кепилдик жана колдоо

For specific warranty information regarding your Diehl 24 hr Spa Timer, please refer to the documentation included with your purchase or contact the retailer from whom the product was acquired. Warranty terms and conditions can vary.

For technical support or further assistance, please contact the manufacturer, Diehl, or your product supplier. Ensure you have your model number (TA4071 or CECOMINOD014742) and purchase details available when seeking support.

Тектеш документтер - CECOMINOD014742

Preview Diehl: Leitfaden für Einladungen und Geschenke
Erfahren Sie mehr über die Richtlinien von Diehl zum sicheren Umgang mit Einladungen жана Geschenken, sowohl im öffentlichen als auch im privaten Sektor, zur Vermeidung von Interessenkonflikten.
Preview Diehl LkSG Complaint Procedure: Guidelines and Reporting
Official procedure from Diehl detailing how to report violations of the German Supply Chain Due Diligence Act (LkSG), covering human rights and environmental concerns, with whistleblower protection.
Preview Diehl LkSG Compliance Procedure: Reporting Violations
Official procedure from Diehl for reporting violations of human rights and environmental standards under the German Supply Chain Due Diligence Act (LkSG), detailing reporting channels, content, and protections.
Preview Reglamento de Procedimiento de Diehl para la Ley de Diligencia Debida en la Cadena de Suministro (LkSG)
Este documento detalla el reglamento y los procedimientos de Diehl para la denuncia de violaciones bajo la Ley Alemana de Diligencia Debida en la Cadena de Suministro (LkSG), abarcando derechos humanos y protección ambiental, e incluyendo la protección al denunciante.
Preview Series 884 Digital Time Clock: Setting Instructions
A guide to setting and operating the Series 884 digital time clock, detailing programming for daily and weekly cycles, setting time and day, and various operational modes.
Preview Германиянын Жеткирүү чынжырчасын талаптагыдай текшерүү актысына (LkSG) ылайык даттануулар үчүн Diehl эрежелери
Бул документ Diehl Group үчүн даттануу процедурасын баяндайт, анда адам укуктарын жана айлана-чөйрөнү коргоо маселелерин камтыган Германиянын Supply Chain Due Diligence Act (LkSG) бузуулар тууралуу кантип кабарлоо керектиги, ошондой эле маалымат берүүчүлөрдү коргоону камсыз кылуу.