1. Продукт бүтүп калдыview
The DIGITUS DN-93903 LSA connection module is designed for connecting or extending twisted pair cables. It provides excellent performance and connection quality for your network infrastructure.
This shielded Cat 6 LSA insulation displacement connector supports transmission characteristics up to 250 MHz and 1GBase-T applications. It is suitable for AWG 22 to AWG 26 solid and stranded conductors.
The module is versatile, suitable for installation in cable ducts, flush-mounted, and surface-mounted applications. It is ideal for extending existing cables or replacing defective cable sections in your network setup.

Image: The DIGITUS LSA connection module showing the internal LSA terminals with color-coded wiring for EIA/TIA 568 A & B standards. An Ethernet cable is connected to a wall outlet, illustrating a typical application.
2. Орнотуу нускамалары
Follow these steps to properly install and connect the DIGITUS DN-93903 LSA connection module:
- Кабелдерди даярдоо: Strip approximately 2-3 cm of the outer jacket from the installation cables you intend to connect. Ensure the twisted pairs remain intact.
- Open Module: Carefully open the LSA connection module to access the LSA insulation displacement terminals.
- Зымды токтотуу: Refer to the color-coded wiring diagram on the LSA terminals (EIA/TIA 568 A or B standard). Untwist the wire pairs minimally and place each individual wire into the corresponding slot on the LSA terminal.
- Коопсуз зымдар: Use an LSA punch-down tool (not included) to press each wire firmly into its slot. The tool will simultaneously cut off any excess wire. Ensure a secure connection.
- Integrated Strain Relief: Utilize the integrated strain relief mechanism to secure the incoming cables, preventing accidental disconnections or damage.
- Close Module: Once all wires are correctly terminated and secured, carefully close the module housing.
- Монтаждоо: Mount the module in your desired location (panel, flush-mounted box, or surface-mounted) using appropriate fasteners (not included).
3. Иштөө нускамалары
The DIGITUS DN-93903 LSA connection module is a passive component designed for permanent cable connections. Once installed, it operates without user intervention.
- Функциясы: The module extends or connects two network installation cables, maintaining the Cat 6 performance standards.
- Байланыш: Ensure that the connected cables are properly terminated and connected to active network equipment (e.g., switches, routers) for network functionality.
- Аткаруу: When correctly installed, the module facilitates data transmission up to 1 Gigabit Ethernet (1GBase-T) with a bandwidth of 250 MHz.
4. Техникалык тейлөө
The DIGITUS DN-93903 LSA connection module requires minimal maintenance due to its robust design.
- Тазалоо: Keep the module free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
- Экологиялык шарттар: Ensure the module is installed in a dry indoor environment, away from excessive moisture, heat, or direct sunlight.
- Текшерүүлөр: Periodically check the cable connections for any signs of wear, damage, or loose wires. Re-terminate if necessary.
5. Кыйынчылыктарды
If you experience network connectivity issues after installing the LSA connection module, consider the following troubleshooting steps:
- Тармак туташуусу жок:
- Verify that all wires are correctly terminated according to the EIA/TIA 568 A or B standard. Incorrect wiring is a common cause of connection failure.
- Ensure that the LSA punch-down tool was used correctly, making firm contact and cutting excess wire.
- Check the integrity of the connected network cables. Test them individually if possible.
- Confirm that all active network equipment (router, switch, PC) is powered on and functioning correctly.
- Жай тармак ылдамдыгы:
- Ensure that all connections are secure and that no wires are loose or partially disconnected.
- Verify that the cables used are Cat 6 compliant to match the module's performance.
- Check for external interference if the module is installed near power cables or other sources of electromagnetic interference. The module is shielded, but proper installation practices are still important.
- Үзгүлтүксүз туташуу:
- Re-examine the LSA terminations for any wires that may have come loose or were not fully seated.
- Ensure the module housing is securely closed and the strain relief is properly applied.
6. Техникалык шарттар
| Өзгөчөлүк | Description |
|---|---|
| Модел | ДН-93903 |
| Трансмиссиянын мүнөздөмөлөрү | 6-категория |
| Колдонуу аймактары | Up to 250 MHz, 1GBase-T |
| Стандарттар | ISO/IEC 11801 3rd Edition, EN 50173-1, EIA/TIA 568-C, ANSI, UL |
| Орнотуу түрү | Suitable for duct, flush-mounted, and surface-mounted installation |
| Кабель орнотуу | LSA-strips, color-coded according to EIA/TIA 568 A & B |
| Conductor Acceptance | AWG 22-26 solid and stranded conductors |
| Турак жай материалы | ABS UL-94V-0 |
| RJ45 Jack Contact Material | Nickel-plated phosphor bronze, 0.5 µ gold-plated contact |
| RJ-45 Shielding Material | Nickel-plated bronze |
| LSA Cutting Clamp Материал | Krone LSA+, UL 94V-0, galvanized phosphor bronze |
| PCB | FR4, UL 94V-0 |
| Иштөө температурасы | -20°Cден +70°Cге чейин |
| Изоляцияга каршылык | > 500 MOhm |
| Байланыш каршылыгы | < 20 milliOhm |
| Диэлектрик күчү | 1000 VDC (contact/contact), 1500 VDC (contact/ground) |
| Продукциянын өлчөмдөрү (D x W x Y) | 15D x 9B x 3H сантиметр |

Сүрөт: жакын план view of the DIGITUS LSA connection module, illustrating its compact size with dimensions of 2.6 inches (6 cm) in length.
7. Кепилдик жана колдоо
Кепилдик маалымат
This DIGITUS DN-93903 LSA Connection Module comes with a 2-year legal warranty. Сураныч, кепилдик дооматтар үчүн сатып алуу далилиңизди сактап коюңуз.
Техникалык колдоо
For technical assistance, installation queries, or troubleshooting beyond the scope of this manual, please contact DIGITUS customer support. Refer to the official DIGITUS webЭң акыркы байланыш маалыматын алуу үчүн сайтка же продуктуңуздун таңгагына кайрылыңыз.
When contacting support, please have your product model number (DN-93903) and a detailed description of your issue ready.