uxcell US-SA-AJD-05010

uxcell USB-KV PLC Programming Cable User Manual

Model: US-SA-AJD-05010

1. Киришүү

This manual provides detailed instructions for the installation, operation, and maintenance of your uxcell USB-KV PLC Programming Cable. This cable facilitates communication between your personal computer and Keyence KV 16/1000 series Programmable Logic Controllers (PLCs) via a USB interface.

2. Продукт бүтүп калдыview

The uxcell USB-KV PLC Programming Cable is designed to convert a USB 2.0 signal to an RJ12 6P6C connection, enabling programming and monitoring of compatible PLCs. It features a built-in indicator light for status feedback.

Негизги өзгөчөлүктөрү:

  • Модел: USB-KV
  • Туташтыргыч түрү: USB 2.0 to RJ12 6P6C
  • Кабелдин узундугу: Болжол менен 2.9 метр (9.5 фут)
  • Material (External): Пластик
  • Түсү: Кара
  • Шайкештик: Designed for Keyence KV 16 and KV 1000 series PLCs.
  • Индикатор жарыгы: Built-in for operational status.
Image showing the USB 2.0 connector and the RJ12 6P6C connector of the programming cable.

Figure 1: USB and RJ12 connectors of the uxcell USB-KV PLC Programming Cable.

Image showing the industrial adapter and interface link module of the programming cable with 'Tx/Rx' indicator.

Figure 2: Industrial adapter module with Tx/Rx indicators on the uxcell USB-KV PLC Programming Cable.

3. Орнотуу нускамалары

3.1 Драйверди орнотуу

Before connecting the cable to your computer, you must install the necessary drivers. The USB-KV cable requires a driver to simulate a traditional serial COM port on your computer, allowing compatibility with existing programming software.

  1. Download the driver from the official source: m8.uxsight.com/public/a12032000ux0133.rar.
  2. Extract the contents of the downloaded RAR archive.
  3. Follow the instructions provided within the driver package to install the USB-KV driver on your Windows operating system. This typically involves running a setup executable or manually updating the driver via Device Manager.
  4. Verify successful installation by checking Device Manager for a new COM port entry after connecting the cable.

3.2 Аппараттык туташуу

Once the drivers are installed, proceed with connecting the cable:

  1. Connect the USB 2.0 end of the cable to an available USB port on your personal computer.
  2. Connect the RJ12 6P6C end of the cable to the programming port on your Keyence KV 16 or KV 1000 series PLC.
  3. Observe the built-in indicator light on the cable's adapter module. It should illuminate, indicating power and potentially data transmission (Tx/Rx).

4. Иштөө нускамалары

After successful driver installation and hardware connection, you can use the programming cable with your PLC software.

  1. Launch your Keyence PLC programming software (e.g., KV STUDIO).
  2. Navigate to the communication settings or port configuration within the software.
  3. Select the COM port number that was assigned to the USB-KV cable during driver installation (you can find this in Device Manager under "Ports (COM & LPT)").
  4. Configure other communication parameters (e.g., baud rate, data bits, parity, stop bits) as required by your PLC and software. Refer to your PLC's documentation for specific settings.
  5. Establish a connection to the PLC. The indicator lights on the cable's adapter module (Tx/Rx) should flash during data transmission.
  6. You can now upload/download programs, monitor PLC status, and perform other programming tasks.

5. Техникалык тейлөө

To ensure the longevity and reliable performance of your uxcell USB-KV PLC Programming Cable, follow these maintenance guidelines:

  • Сактагыч: Кабельди күн нурунан жана экстремалдык температурадан алыс салкын, кургак жерде сактаңыз.
  • Колдонуу: Avoid bending or kinking the cable sharply, especially near the connectors, as this can damage internal wires.
  • Тазалоо: Use a soft, dry cloth to clean the cable and connectors. Do not use liquid cleaners or solvents.
  • Текшерүү: Periodically inspect the cable for any signs of damage, such as frayed insulation, bent pins, or cracked connectors. Replace the cable if any damage is found.
  • Ажыратууда: Always grasp the connector housing when disconnecting the cable, not the cable itself, to prevent strain on the wires.

6. Кыйынчылыктарды

If you encounter issues while using the uxcell USB-KV PLC Programming Cable, refer to the following troubleshooting tips:

КөйгөйМүмкүн себепЧечим
Cable not recognized by PC / No COM port appears.
  • Drivers not installed or incorrectly installed.
  • Faulty USB port on PC.
  • Бузулган кабель.
  • Ensure drivers are correctly installed from the provided link.
  • Компьютериңиздеги башка USB портун колдонуп көрүңүз.
  • Test the cable on another computer if possible.
Cannot connect to PLC.
  • Incorrect COM port selected in software.
  • Incorrect communication parameters (baud rate, etc.).
  • PLC not powered on or in programming mode.
  • Бошоң байланыш.
  • Verify the COM port in Device Manager and select it in your PLC software.
  • Check PLC documentation for correct communication settings.
  • Ensure PLC is powered and ready for communication.
  • Securely connect both ends of the cable.
Indicator lights (Tx/Rx) not flashing during data transfer.
  • No data being transmitted.
  • Connection issue.
  • Кабелдин катасы.
  • Initiate a data transfer (e.g., upload/download program) to see if lights flash.
  • Бардык байланыштарды кайра текшериңиз.
  • Ensure PLC is communicating.

7. Техникалык шарттар

ӨзгөчөлүкДеталь
Продукт атыPLC кабели
МоделUSB-KV (US-SA-AJD-05010)
Брендuxcell
Туташтыргыч түрүUSB 2.0 to RJ12 6P6C
Кабелдин узундугу2.9 метр (9.5 фут)
Material (External)Пластик
ТүсКара
Таза Салмак133г (0.29 фунт)
Шайкеш түзмөктөрPC, Keyence KV 16/1000 PLCs
UPC741238860423

8. Кепилдик жана колдоо

For technical support or inquiries regarding your uxcell USB-KV PLC Programming Cable, please contact uxcell customer service through their official channels. Refer to your purchase documentation or the uxcell webатайын кепилдик маалымат жана байланыш маалыматы үчүн сайт.

Эскертүү: This is a non-OEM product. Ensure compatibility with your specific Keyence PLC model before use.

© 2023 uxcell. All rights reserved.