1. Киришүү

This manual provides detailed instructions for the installation, operation, and maintenance of the Johnson Controls V-9012-1 E/P Solenoid Relay. This device is designed to convert an electrical signal into a pneumatic output, controlling air pressure based on a 12 VDC input. Please read this manual thoroughly before attempting any installation or operation to ensure safe and efficient use of the product.

2. Коопсуздук маалыматы

Adherence to safety precautions is crucial for preventing injury and damage to the equipment. Always follow local codes and regulations.

  • Квалификациялуу кадрларды: Installation and servicing must be performed by qualified and experienced personnel only.
  • Электр коопсуздугу: Disconnect all power to the device and associated equipment before performing any wiring or maintenance. Ensure proper grounding.
  • Pneumatic Safety: Depressurize all pneumatic lines before making or breaking connections. Wear appropriate personal protective equipment.
  • Экологиялык шарттар: Do not expose the device to conditions outside its specified operating range (temperature, humidity, pressure).

3. Продукт бүтүп калдыview

The Johnson Controls V-9012-1 is an Electro-Pneumatic (E/P) Solenoid Relay that converts a 12 VDC electrical input into a pneumatic control signal. It is commonly used in industrial applications to manage air pressure for actuators or other pneumatic devices.

3.1. Негизги өзгөчөлүктөрү

  • 12 VDC Input for electrical control.
  • Solenoid Valve functionality for precise pneumatic regulation.
  • Relay operation for switching pneumatic states.
  • Maximum input current of 50 mA.

3.2. Components and Labeling

Refer to the image below for a visual representation of the V-9012-1 Solenoid Valve Relay and its key labeled components.

Johnson Controls V-9012-1 E/P Solenoid Relay with labels

Figure 1: Johnson Controls V-9012-1 E/P Solenoid Relay

The image displays the Johnson Controls V-9012-1 E/P Solenoid Relay. Key labels visible on the device include:

  • V-9012-1 E/P SOLENOID RELAY: Identifies the model and type of device.
  • PAT 4,770,200 and PAT 4,804,009: Patent numbers associated with the product.
  • BO TERM. 1 (RED): Indicates the first electrical terminal, typically for the positive 12 VDC input.
  • 12 V.D.C. INPUT (50 mA. MAX.): Specifies the required input voltage жана максималдуу ток.
  • BO TERM. 2 (BLK) RESISTOR: Indicates the second electrical terminal, typically for the negative connection, and notes the presence of a resistor.
  • БЕРҮҮ: The inlet port for the pneumatic supply pressure.
  • ACTUATOR: The outlet port for the controlled pneumatic pressure to the actuator.
  • +12 V.D.C. PRESS.: Indicates that a +12 VDC input results in a 'PRESS' (pressure) state.
  • 0 V.D.C. HOLD: Indicates that 0 VDC input results in a 'HOLD' state.
  • -12 V.D.C. EXHAUST: Indicates that a -12 VDC input results in an 'EXHAUST' state.

4. Орнотуу жана орнотуу

Proper installation is critical for the correct functioning of the V-9012-1 Solenoid Relay.

4.1. Орнотууга чейинки текшерүүлөр

  • Verify that the power supply matches the device's requirements (12 VDC).
  • Inspect the device for any visible damage from shipping.
  • Ensure all necessary tools and fittings are available.

4.2. Монтаждоо

Mount the solenoid relay securely in a location that is free from excessive vibration, moisture, and extreme temperatures. Ensure adequate space for wiring and pneumatic connections.

4.3. Электр зымдары боюнча нускамалар

Электр байланыштары үчүн бул кадамдарды аткарыңыз:

  1. Ensure the power source is completely disconnected.
  2. Connect the positive (+) 12 VDC power supply wire to BO TERM. 1 (RED).
  3. Connect the negative (-) 12 VDC power supply wire to BO TERM. 2 (BLK). Note that this terminal includes a resistor.
  4. Бардык байланыштар коопсуз жана туура изоляцияланганын текшериңиз.

4.4. Пневматикалык туташуулар

Follow these steps for pneumatic connections:

  1. Connect the main pneumatic supply line to the port labeled СУПЕР. Ensure the supply pressure is within the device's specified operating range.
  2. Connect the line leading to the pneumatic actuator or controlled device to the port labeled АКТУАТОР.
  3. Check all pneumatic connections for leaks after pressurizing the system.

5. Операция

The V-9012-1 Solenoid Relay operates based on the applied electrical input voltage, controlling the pneumatic output to the actuator.

  • +12 VDC Input: When a positive 12 VDC is applied to the input terminals, the relay will enter a 'PRESS' state, allowing supply pressure to flow to the actuator.
  • 0 VDC Input: When 0 VDC (no voltage) is applied, the relay will enter a 'HOLD' state, maintaining the current pneumatic output.
  • -12 VDC Input: When a negative 12 VDC is applied, the relay will enter an 'EXHAUST' state, releasing pressure from the actuator.

Ensure that the control system provides the correct voltage signals for the desired pneumatic response.

6. Техникалык тейлөө

The Johnson Controls V-9012-1 Solenoid Relay is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure longevity and optimal performance.

  • Күнүмдүк текшерүү: Periodically inspect the device for any signs of wear, corrosion, or damage to the housing, wiring, and pneumatic connections.
  • Тазалоо: Keep the exterior of the device clean and free from dust and debris. Do not use harsh chemicals or abrasive cleaners.
  • Туташуу бүтүндүгү: Verify that all electrical and pneumatic connections remain tight and secure.
  • Кесиптик кызмат: For internal issues or complex repairs, contact a qualified service technician or Johnson Controls support. Do not attempt to disassemble the unit.

7. Кыйынчылыктарды

This section provides solutions to common issues that may arise during the operation of the V-9012-1 Solenoid Relay.

КөйгөйМүмкүн себепЧечим
Device does not respond to electrical input.Кубат жок, туура эмес томtage, loose wiring, internal fault.Check 12 VDC power supply. Verify wiring connections to Terminals 1 and 2. Ensure correct polarity. If problem persists, contact support.
Pneumatic output is incorrect or inconsistent.Insufficient supply pressure, clogged lines, leaks in pneumatic connections, internal valve issue.Check pneumatic supply pressure. Inspect lines for obstructions or leaks. Ensure correct electrical input for desired pneumatic state.
Түзмөк ашыкча ысып жатат.Excessive current, improper ventilation, continuous operation beyond duty cycle.Verify input current does not exceed 50 mA. Ensure adequate airflow around the device. Review application for duty cycle requirements.

8. Техникалык шарттар

Technical specifications for the Johnson Controls V-9012-1 E/P Solenoid Relay:

ПараметрНарк
Модель номериV-9012-1
ФункцияE/P Solenoid Relay
Киргизүү көлөмүtage12 VDC
Максималдуу киргизүү ток50 мА
Pneumatic StatesPress (+12 VDC), Hold (0 VDC), Exhaust (-12 VDC)
ӨндүрүүчүДжонсон КОНТРОЛЬС
Элемент Салмагы6.4 унция
Дата биринчи жеткиликтүү5-июль, 2012-жыл

9. Кепилдик жана колдоо

For information regarding product warranty, technical support, or service, please contact Johnson Controls directly through their official website or customer service channels. Keep your purchase receipt and product model number readily available when seeking support.

Тектеш документтер - V-9012-1

Preview Johnson Controls Bronze Cage Trim Valves: 3/4 to 2 Inch Product Guide
Comprehensive technical guide for Johnson Controls Bronze Cage Trim Valves (3/4 to 2 Inch), detailing features, pneumatic and electric actuator options, specifications, operation, installation, and repair parts for HVAC applications.
Preview Johnson Controls EP-8000 Series Electro-Pneumatic Transducers: Technical Specifications, Installation, and Operation
Detailed technical bulletin for Johnson Controls EP-8000 Series Electro-Pneumatic Transducers. Covers product overview, operation, dimensions, installation, wiring, calibration, and technical specifications for industrial control applications.
Preview VG7000 сериясындагы коло башкаруу клапандарын орнотуу боюнча колдонмо
Comprehensive installation instructions and technical specifications for the Johnson Controls VG7000 Series Bronze Control Valves, designed for regulating water and steam in HVAC systems. Includes valve dimensions, materials, and operating parameters.
Preview Джонсон Controls клапан оңдоо бөлүктөрүнүн каталогу
Диафрагмаларды, пружиналарды, таңгактарды, реконструкциялоо комплекттерин жана Johnson Controls пневматикалык жана электрдик клапандардын кеңири спектри үчүн башка компоненттерди камтыган алмаштыруучу бөлүктөрдү чагылдырган комплекстүү каталог.
Preview Johnson Controls CSD сериясынын бөлүнгөн өзөктүү учурдагы түзмөгүн орнотуу боюнча колдонмо
Johnson Controls CSD сериясындагы реле менен бөлүнгөн өзөктүү ток түзмөктөрүн (CSD-CF0J1-1, CSD-CA1G1-1) орнотуу жана техникалык колдонмо. Өнөр жайлык токту көзөмөлдөө үчүн колдонмолорду, зымдарды, калибрлөөнү, көйгөйлөрдү чечүүнү жана спецификацияларды камтыйт.
Preview VP1000 Compact Globe (Axial) Control Valve Installation Guide
Installation guide for the Johnson Controls VP1000 Compact Globe (Axial) control valve, covering sizes 1/2 Inch to 1 1/4 Inch (DN15-DN32). Provides technical specifications, mounting instructions, and maintenance information.