Project E Beauty PE-921P

Project E Beauty Pro High Frequency Galvanic Roller Beauty Facial Skin Care Spa Salon Machine

User Manual - Model PE-921P

1. Продукт бүтүп калдыview

The Project E Beauty Pro High Frequency Galvanic Roller is a professional-grade device designed for facial skin care. It combines high frequency and galvanic technologies to help improve skin texture, circulation, and product absorption. This machine is suitable for use in spa, salon, or home settings, offering a comprehensive solution for various skin concerns.

Project E Beauty Pro High Frequency Galvanic Roller Machine with accessories

Сүрөт 1.1: The Project E Beauty Pro High Frequency Galvanic Roller machine, showcasing its main unit with control knobs and various attachments including the roller, glass electrodes, and power cord.

2. Коопсуздук чаралары

Before operating the device, please read and understand all safety instructions. Improper use can lead to injury or damage to the device.

3. Орнотуу

  1. Пакеттен чыгаруу: Carefully remove all components from the packaging. Verify that all parts are present: main unit, power cord, high frequency electrodes (various shapes), and galvanic roller/accessories.

  2. Жайгашкан жери: Place the main unit on a stable, flat, and dry surface, away from direct sunlight or heat sources.

  3. Кубат туташуу: Insert the power cord into the power input port on the back of the main unit, then plug the other end into a suitable electrical outlet.

  4. Attaching Electrodes/Roller:

    • For High Frequency: Gently insert the desired glass electrode into the high frequency handle. Ensure it is securely seated.
    • For Galvanic: Connect the galvanic roller or other galvanic accessories to their respective ports on the main unit.

  5. Ensure all connections are firm before powering on the device.

4. Иштөө нускамалары

This section details the operation of both High Frequency and Galvanic functions.

4.1. High Frequency Operation

  1. Даярдоо: Ensure the skin is clean and dry. Apply a thin layer of gauze or a suitable high-frequency cream/serum to the treatment area.

  2. Күйгүзүү: Turn on the main power switch. Select the High Frequency function.

  3. Электродду киргизүү: Insert the chosen glass electrode into the high frequency handle. Ensure the intensity knob is at its lowest setting before starting.

  4. Колдонмо: Place the electrode directly onto the skin before turning up the intensity to avoid a mild shock. Slowly increase the intensity using the High Frequency intensity knob until a comfortable sensation is felt.

  5. Дарылоо: Move the electrode in circular motions over the treatment area. Typical session duration is 5-10 minutes per area.

  6. Аяктоо: Lower the intensity to zero, then remove the electrode from the skin before turning off the High Frequency function.

4.2. Galvanic Operation

  1. Даярдоо: Cleanse the skin thoroughly. Apply a conductive gel or solution suitable for galvanic treatments. Ensure the client holds the passive electrode (if applicable) or that the active electrode is properly grounded.

  2. Күйгүзүү: Turn on the main power switch. Select the Galvanic function.

  3. Polarity Selection: Select the desired polarity (positive or negative) based on the treatment goal (e.g., desincrustation or iontophoresis).

  4. Колдонмо: Place the galvanic roller or chosen active electrode onto the skin. Slowly increase the intensity using the Galvanic intensity knob until a comfortable sensation is felt. The client should feel a slight tingling.

  5. Дарылоо: Glide the electrode smoothly over the skin, maintaining constant contact. Avoid lifting the electrode from the skin while the current is active. Typical session duration is 10-15 minutes.

  6. Аяктоо: Lower the intensity to zero, then remove the electrode from the skin before turning off the Galvanic function.

5. Техникалык тейлөө

Туура тейлөө аппаратыңыздын узак мөөнөттүү жана оптималдуу иштешин камсыз кылат.

6. Кыйынчылыктарды

Эгер түзмөгүңүздө көйгөйлөргө туш болсоңуз, төмөнкү жалпы көйгөйлөрдү жана чечимдерди караңыз:

КөйгөйМүмкүн себепЧечим
Түзмөк күйбөйт.Power cord not properly connected; power outlet issue; main power switch off.Check power cord connection. Try a different outlet. Ensure main power switch is in the 'ON' position.
No sensation during High Frequency treatment.Intensity too low; electrode not making proper contact; skin too dry.Slowly increase intensity. Ensure electrode is firmly on the skin. Apply a suitable conductive medium.
No sensation during Galvanic treatment.Intensity too low; insufficient conductive gel; poor contact with passive electrode (if used).Slowly increase intensity. Ensure sufficient conductive gel is applied. Verify proper contact with all electrodes.
Sparking when High Frequency electrode touches skin.Electrode not placed on skin before increasing интенсивдүүлүгү.Always place the electrode on the skin first, then slowly increase intensity. Remove electrode from skin only after reducing intensity to zero.

If the problem persists after attempting these solutions, please contact Project E Beauty customer support for further assistance.

7. Техникалык шарттар

Модель номериPE-921P
БрендProject E Beauty
Продукциянын өлчөмдөрү (LxWxH)35 x 22.5 x 28.5 см
Элемент Салмагы3.5 кг
Теринин түрү шайкештигиБаары
ӨндүрүүчүProject E Beauty

8. Кепилдик жана колдоо

Project E Beauty products are manufactured to high quality standards. For information regarding warranty coverage, please refer to the warranty card included with your purchase or visit the official Project E Beauty webсайт.

For technical support, troubleshooting assistance beyond this manual, or to inquire about replacement parts, please contact Project E Beauty customer service. Contact details can typically be found on the product packaging or the official brand webсайт.

Note: Always purchase genuine Project E Beauty products from authorized retailers to ensure warranty validity and product authenticity.