Introduction
The AC Infinity CLOUDPLATE T7-N is an intelligent fan system specifically designed for cooling audio video, DJ, server, network, and IT equipment racks. Maintaining an optimal temperature for rack-mount equipment is crucial to prevent overheating, ensure consistent performance, and extend their operational lifespan. This manual provides essential information for the proper setup, operation, and maintenance of your CLOUDPLATE T7-N unit.
Коопсуздук маалыматы
- электр менен жабдууну камсыз кылуу voltage matches the requirements specified for the unit.
- Бузулган шнурлар же сайгычтар менен шайманды иштетпеңиз.
- Түзмөктү суудан же ашыкча нымдуулуктан алыс кармаңыз.
- Do not block the fan intake or exhaust vents.
- Кандайдыр бир тейлөө же орнотууну аткаруудан мурун ар дайым электр кубатын ажыратыңыз.
Пакеттин мазмуну
Толук комплект төмөнкү буюмдарды камтыйт:
- 1 x CLOUDPLATE T7-N 2U Fan Unit
- 1 x Corded 6-ft Thermal Probe
- 1 x Колдонуучунун колдонмосу (бул документ)
- Rack Mount Screws
- Cage Nuts
- 1 x Corded 6-ft Power Supply

Image: Included accessories for the CLOUDPLATE T7-N, showing the thermal probe, power adapter, and mounting screws.
Продукт бүттүview
The CLOUDPLATE T7-N is housed in a solid anodized aluminum construction, occupying two rack units (2U) of space. It features CNC-machined detailing for a professional appearance. This model is designed for intake airflow, drawing cooler air into the rack, and should typically be positioned near the bottom.
The unit incorporates four custom-engineered dual-ball bearing fans, rated for 67,000 hours of operation and certified by CE and RoHS. These fans utilize a PWM motor and spiral-curved blade design to maximize airflow at lower speeds while minimizing noise levels.

Сүрөт: деталдуу view of a dual-ball bearing fan with PWM motor, designed for high performance and minimal noise.
Жайгашуу
- Стойкага орнотуу: Identify a 2U space in your 19-inch equipment rack. Use the provided rack mount screws and cage nuts to securely install the CLOUDPLATE T7-N unit. Ensure the unit is flush with the rack rails.
- Thermal Probe Connection: Connect the corded 6-ft thermal probe to the designated port on the unit. Position the probe within the rack where you want to monitor the temperature, typically near heat-generating equipment.
- Кубат туташуу: Connect the provided 6-ft power supply to the unit and then to a standard electrical outlet.
- Баштапкы күйгүзүү: Once all connections are secure, the unit will power on, and the LCD display will activate.

Image: The CLOUDPLATE T7-N unit seamlessly integrated into a standard equipment rack.

Image: Illustrates the intake airflow design, with cool air entering from the bottom and warm air exiting the top of the rack.
Иштөө нускамалары
The CLOUDPLATE T7-N features an LCD digital controller with a programmable thermostat and automated speed control. This allows the system to react to varying temperatures efficiently.
- SMART режими: This mode automatically adjusts the fan speed based on the temperature detected by the thermal probe. You can set a target temperature and a buffer, and the fans will increase speed as the temperature rises above the target plus buffer.
- Кол режими: Manually select one of six available fan speeds to maintain a constant airflow, regardless of temperature.
- Температура сигналдары: The controller can be set to trigger alarm warnings if the temperature exceeds a user-defined threshold.
- Fan Failure Triggers: The system monitors fan operation and can alert you in case of a fan failure.
- Дисплейдин жөндөөлөрү: Adjust screen brightness with three available settings. The display also features a lock function to prevent accidental changes.
- Камдык эстутум: Settings are saved even if power is interrupted.
- Кеңейтүү порту: An expansion port at the rear allows for daisy-chaining additional CLOUDPLATE units or AC Infinity rack roof dual-fan kits to share the same control programming for enhanced cooling.

Image: The intelligent programming display showing current temperature, set temperature, fan speed, and buffer settings.
Video: An official product video demonstrating the features and functionality of the CLOUDPLATE Series rack mount cooling fan systems.
Техникалык тейлөө
Regular maintenance ensures optimal performance and longevity of your CLOUDPLATE T7-N unit.
- Тазалоо: Periodically inspect the fan grilles and blades for dust accumulation. Use a soft brush or compressed air to gently clean the fans and vents. Ensure the unit is powered off and unplugged before cleaning.
- Thermal Probe: Keep the thermal probe clean and free from obstructions to ensure accurate temperature readings.
- Байланыштары: Periodically check all cable connections (power, thermal probe, expansion) to ensure they are secure.
Проблемаларды чечүү
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Fans not spinning / Display off | No power, loose connection, power adapter issue. | Check power cable connection to unit and outlet. Ensure outlet is functional. Try a different power adapter if available. |
| Температураны туура эмес окуу | Thermal probe improperly placed or damaged. | Ensure thermal probe is securely connected and positioned correctly. Avoid placing it directly on hot components. Check for physical damage to the probe. |
| Fans running too fast/slow in SMART mode | Incorrect temperature settings (SET, BUFFER). | Adjust the SET temperature and BUFFER values on the controller to match your desired cooling profile. |
| Бирдиги ызы -чуу | High fan speed, dust accumulation, fan bearing issue. | Lower the fan speed setting. Clean the fan blades and grilles. If noise persists at low speeds, contact support. |
| Alarm warning displayed | Temperature exceeded alarm threshold, fan failure. | Check the current temperature. If it's too high, increase fan speed or check for obstructions. If it's a fan failure warning, inspect fans for operation. |
Техникалык шарттар
| Өзгөчөлүк | Деталь |
|---|---|
| Модел | AI-CP2H |
| Rack Space | 2U |
| Дизайн | Кабыл алуу |
| Жалпы аба агымы | 50дөн 220 XNUMX XNUMX CFMге чейин |
| Total Noise | 10ден 36 дБАга чейин |
| Статикалык басым | 2.56 мм-Н2О |
| Operating Voltage | 12V DC |
| Күч | 10 Вт |
| Учурдагы | 0.83 А |
| Дубал адаптерин киргизүү | 100дөн 240V AC |
| Иштөө нымдуулугу | 35-85% RH |
| Иштөө температурасы | 0…158°F (0…70°C) |
| Желдетүүчү подшипниктер | Dual Ball |
| L10 Life Expectancy | 67,000 саат |
| Жалпы Өлчөмдөр | 19.0 x 3.5 x 1.5 дюйм (48.3 x 8.9 x 3.8 см) |
| Материал | Алюминий |

Image: Visual representation of the unit's dimensions and core performance specifications.
Кепилдик маалымат
Specific warranty details for the AC Infinity CLOUDPLATE T7-N are typically provided with the product packaging or can be found on the official AC Infinity website. Please refer to these resources for the most current and comprehensive warranty terms and conditions.
Колдоо
Кошумча жардам, техникалык колдоо же үчүн view additional product documentation, please visit the official AC Infinity website. You may find FAQs, troubleshooting guides, and contact information for customer service there.
AC Infinity Webсайт: www.acinfinity.com