Sloan EBV129A-U

Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module for Urinal User Manual

Model: EBV129A-U

1. Киришүү

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module for Urinals. This module is designed to provide reliable, hands-free flushing for G2 Optima Plus flushometers, enhancing hygiene and water conservation in commercial and public restrooms.

2. Коопсуздук маалыматы

Please read all safety instructions before installation and operation. Failure to follow these instructions may result in property damage, personal injury, or improper product function.

  • Орнотуу же техникалык тейлөө иштерин баштоодон мурун ар дайым суу менен камсыздоону өчүрүңүз.
  • Ensure all electrical connections are made by a qualified electrician if applicable, and comply with local codes.
  • Коопсуздук көз айнеги жана кол кап сыяктуу тиешелүү жеке коргонуу каражаттарын (ЖКК) кийиңиз.
  • Do not attempt to modify the product. Use only genuine Sloan replacement parts.
  • Балдарды орнотуу аянтынан алыс кармаңыз.

3. Пакеттин мазмуну

Орнотууну баштоодон мурун бардык компоненттер бар экендигин текшериңиз:

  • Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module
  • Монтаждоочу жабдык (эгер бар болсо)
  • Нускама баракчасы (бул документ)

Note: Additional components for the complete flushometer system are sold separately.

4. Орнотуу жана орнотуу

Installation should be performed by a qualified plumber or technician.

  1. Prepare the Urinal: Ensure the urinal and existing flushometer body are clean and free of debris. Turn off the main water supply to the urinal.
  2. Учурдагы компоненттерди алып салуу: Carefully remove any old sensor modules or manual flush handles from the flushometer.
  3. Install the Sensor Module: Position the EBV129A-U module onto the flushometer body according to the specific G2 Optima Plus flushometer model's instructions. Ensure proper alignment and secure attachment.
  4. Зымдарды туташтыруу (эгер бар болсо): If the module requires external power or data connections, connect them securely following the wiring diagram provided with your specific flushometer model. Ensure all connections are watertight.
  5. Суу менен камсыздоону калыбына келтирүү: Акырындык менен суу менен камсыздоону күйгүзүңүз жана агып кеткендигин текшериңиз.
  6. Сыноо операциясы: Allow the sensor to calibrate for a few moments. Step away from the urinal, then approach it to trigger the sensor. The flushometer should activate automatically.
Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module for Urinal

1-сүрөт: Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module. This image shows the compact electronic sensor module, typically installed on a urinal flushometer to enable automatic, hands-free flushing. It features a sensor window and connection points for integration with the flushometer system.

5. Иштөө нускамалары

The Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module provides fully automatic, hands-free operation for urinals equipped with compatible G2 Optima Plus flushometers.

  • Автоматтык жуу: The sensor detects the user's presence and initiates a flush cycle after the user departs.
  • Сенсор диапазону: The sensor is factory-set for optimal detection range. Avoid placing objects directly in front of the sensor that could obstruct its view or cause false activations.
  • Кол менен жокко чыгаруу (эгер бар болсо): Some G2 Optima Plus flushometers may feature a manual override button. Refer to your specific flushometer's manual for details on this function.

6. Техникалык тейлөө

Regular maintenance ensures optimal performance and longevity of your sensor module.

  • Тазалоо: Clean the sensor lens regularly with a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the sensor surface.
  • Battery Replacement (if battery-powered): If your G2 Optima Plus flushometer system uses batteries for the sensor module, replace them as indicated by a low battery indicator or when the flushometer stops responding. Refer to your flushometer's manual for specific battery type and replacement procedures.
  • Текшерүү: Periodically inspect the module for any signs of damage or loose connections.

7. Кыйынчылыктарды

If you experience issues with your sensor module, consult the following table before contacting support.

КөйгөйМүмкүн себепЧечим
No flush when user departsObstructed sensor lens, low battery (if applicable), water supply off, faulty module.Clean sensor lens. Replace batteries. Check water supply valve. Contact Sloan support if problem persists.
Үзгүлтүксүз жуунууSensor obstruction, faulty sensor, internal flushometer issue.Remove any objects near sensor. Check for reflective surfaces. Consult flushometer manual. Contact Sloan support.
Начар же толук эмес жууLow water pressure, partially closed stop valve, flushometer diaphragm issue.Check water pressure. Ensure stop valve is fully open. Consult flushometer manual for diaphragm inspection.

8. Техникалык шарттар

  • Модель номери: DT-39901 (EBV129A-U)
  • Бренд: Слоан
  • Материал: Металл
  • Тышкы жасалгалоо: Дат баспаган болот
  • Кирүү туташуу өлчөмү: 1 дюйм
  • Кирүүчү туташуу түрү: Фланец
  • Outlet Connection Size: 2 дюйм
  • Розетка туташуу түрү: Клапан туташтыруу түрү
  • Порттардын саны: 2
  • Клапандын түрү: Глобус клапан
  • Өлчөмү: 1 дюйм x 2 дюйм
  • Элемент Салмагы: 0.01 унция
  • Техникалык мүнөздөмөлөрү: CSA, ULC
  • UPC: 733353562306

9. Кепилдик жана колдоо

Sloan products are manufactured to the highest standards and are backed by a limited warranty. For specific warranty details, please refer to the warranty information included with your original flushometer purchase or visit the official Sloan webсайт.

For technical assistance, replacement parts, or further inquiries, please contact Sloan Customer Support:

  • Webсайт: www.sloan.com
  • Телефон: Refer to the Sloan webаймактык байланыш номерлери үчүн сайт.