1. Продукт бүтүп калдыview
This manual provides essential information for the installation, operation, and maintenance of the PRV AUDIO 3/4" 100 PSI Pressure Relief Valve. This valve is designed to protect water piping and pressure tanks from damage due to excessive pressure by automatically releasing water when the system pressure exceeds 100 PSI. It is specifically recommended for use in cold water system installations.
The valve is constructed from lead-free brass, ensuring safety and compliance with plumbing standards. Its design features a 3/4" male thread for connection to a tank or tank tee and a 3/4" female thread for plumbing to a drain.

Image 1.1: The PRV AUDIO 3/4 inch 100 PSI Pressure Relief Valve. This image shows the brass construction, the male threaded inlet on the left, and the female threaded outlet on the right, with the pressure relief mechanism visible at the top right.
2. Орнотуу жана орнотуу
Proper installation is crucial for the safe and effective operation of the pressure relief valve. Always ensure the water supply is turned off before beginning installation.
2.1. Коопсуздук чаралары
- Ensure the water system is depressurized before installation.
- Коргоочу көз айнек жана кол кап сыяктуу тиешелүү жеке коргонуу шаймандарын (ЖКК) кийиңиз.
- Confirm the valve's pressure rating (100 PSI) is suitable for your system's requirements.
2.2. Орнотуу кадамдары
- Орнотуу жерин аныктоо: The valve should be installed on the cold water supply line or directly on the pressure tank/tank tee where overpressure protection is required.
- Байланыштарды даярдоо: The valve features a 3/4" male NPT thread for connection to the pressure tank or system piping. Apply appropriate thread sealant (e.g., PTFE tape or pipe dope) to the male threads.
- Системага туташуу: Carefully thread the valve into the designated female port on the pressure tank or plumbing tee. Tighten securely but do not overtighten to avoid damaging threads or the valve body.
- Дренажга туташуу: The valve has a 3/4" female NPT thread for connecting a discharge pipe. This pipe must lead to an appropriate drain location, ensuring that any discharged water can be safely managed without causing damage or hazard. Ensure the drain line is adequately sized and sloped for proper drainage.
- Суу менен камсыздоону калыбына келтирүү: Once the valve is securely installed and the drain line is connected, slowly open the main water supply valve to repressurize the system.
- Агышууларды текшерүү: Бардык туташууларды агып кетүү белгилери бар-жогун текшериңиз. Зарыл болсо, туташууларды бекемдеңиз.
3. Иштөө нускамалары
The PRV AUDIO Pressure Relief Valve operates automatically. It is designed to open and discharge water when the system pressure reaches or exceeds its set point of 100 PSI, thereby preventing damage to the water system components.
- The valve will remain closed under normal operating pressures below 100 PSI.
- When system pressure rises above 100 PSI, the valve will automatically open to relieve the excess pressure.
- Once the system pressure drops back below 100 PSI, the valve will automatically close.
- No manual intervention is required for its primary pressure relief function.
4. Техникалык тейлөө
Regular inspection of the pressure relief valve is recommended to ensure its continued proper function and system safety.
- Визуалдык текшерүү: Periodically check the valve and its connections for any signs of corrosion, damage, or leaks.
- Чыгаруу түтүгүн текшерүү: Ensure the discharge line is clear of obstructions and properly routed to a safe drain.
- Testing (Optional, Consult Professional): Some pressure relief valves can be manually tested by lifting a lever or turning a knob to ensure they open and close. However, for this specific valve, manual testing may not be applicable or recommended without professional guidance, as it could lead to water discharge. If you suspect the valve is not functioning correctly, consult a qualified plumber.
- Тазалоо: Do not attempt to disassemble or clean the internal components of the valve. If the valve is fouled or not operating correctly, replacement is generally recommended.
5. Кыйынчылыктарды
This section addresses common issues that may arise with the pressure relief valve.
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Valve leaks continuously or drips |
|
|
| Valve does not open when pressure is high |
|
|
| Water discharge is insufficient |
|
|
If troubleshooting steps do not resolve the issue, or if you are unsure about any procedure, it is highly recommended to contact a qualified plumbing professional.
6. Техникалык шарттар
| Атрибут | Деталь |
|---|---|
| Модель номери | PRV_PressureRelief_34_100 |
| Материал | NO LEAD BRASS |
| Сырткы бүтүрүү | Жез |
| Inlet Connection Size | 0.75 дюйм (3/4") |
| Inlet Connection түрү | Threaded (Male NPT) |
| Розетка туташуу өлчөмү | 0.75 дюйм (3/4") |
| Розетка туташуу түрү | NPT (Female) |
| Максималдуу иштөө басымы | 100 PSI (бир чарчы дюйм үчүн фунт) |
| Порттардын саны | 2 |
| Пакеттин өлчөмдөрү | 2.95 x 1.85 x 1.14 дюйм |
| Пакет Салмагы | 5.93 унция |
| Өндүрүүчү | PRV |
| Дата биринчи жеткиликтүү | 12-октябрь, 2017-жыл |
7. Кепилдик жана колдоо
Specific warranty information for the PRV AUDIO Pressure Relief Valve is not provided within this manual. For details regarding product warranty, returns, or technical support, please refer to the original purchase documentation or contact the seller or manufacturer directly.
You may visit the official PRV AUDIO store on Amazon for more information: PRV AUDIO Store