This manual provides detailed instructions for the safe and proper installation and use of the Satco 80-2629 Four Light Ballast Bypass Wiring Harness. This harness is designed to convert fluorescent fixtures to operate with linear LED T8 lamps that require a ballast bypass (direct wire) installation. Please read all instructions carefully before beginning installation.

Satco 80-2629 Four Light Ballast Bypass Wiring Harness

Image 1: Satco 80-2629 Four Light Ballast Bypass Wiring Harness. This image shows the complete wiring harness with connectors for four T8 LED lamps.

2. Коопсуздук маалыматы

  • ЭСКЕРТҮҮ: Электр шок коркунучу. Орнотуудан же тейлөөдөн мурун автоматтык өчүргүчтөн же сактагыч кутудан электрди өчүрүңүз.
  • Installation should be performed by a qualified electrician or certified professional.
  • Бардык зымдарды туташтыруу коопсуз жана жергиликтүү электр коддоруна ылайык экенин текшериңиз.
  • Do not use with fluorescent lamps же LED lamps that require a ballast. This harness is for ballast bypass (direct wire) LED T8 lampс гана.
  • Inspect the harness for any damage before installation. Do not install if damaged.

3. Пакеттин мазмуну

Орнотууну баштоодон мурун бардык компоненттер бар экендигин текшериңиз:

  • One (1) Satco 80-2629 Four Light Ballast Bypass Wiring Harness

4. Орнотуу жана орнотуу

This harness is designed for converting a four-lamp fluorescent fixture to operate with four ballast bypass LED T8 lamps. Professional installation is highly recommended.

  1. Кубатты өчүрүү: Turn off power to the fixture at the circuit breaker or fuse box. Verify power is off using a voltage сыноочу.
  2. Access Fixture Wiring: Remove the fixture cover and existing fluorescent lamps. Locate and identify the existing ballast.
  3. Remove Existing Ballast: Disconnect all wires leading to and from the existing ballast. Remove the ballast from the fixture.
  4. Install Wiring Harness:
    • Connect the black wire from the Satco 80-2629 harness to the LINE (ЫСТЫК) wire from the fixture's power supply.
    • Connect the white wire from the Satco 80-2629 harness to the БЕЙТРАЛ wire from the fixture's power supply.
    • Ensure all connections are secured with appropriate wire connectors (not included).
  5. Лamp Ээлери: The harness provides four sets of lamp holder wires. Each set connects directly to the tombstone (lamp holder) for one LED T8 lamp. Ensure that the wiring to each tombstone provides power to one end of the LED lamp, and neutral to the other end, as required by your specific LED T8 lamps. (Some LED T8 lamps are single-ended power, others are double-ended. Consult your LED lamp көрсөтмөлөр.)
  6. Install LED T8 Lamps: Insert the ballast bypass LED T8 lamps салып lamp ээлери.
  7. Коопсуз арматура: Replace the fixture cover.
  8. Күчтү калыбына келтирүү: Turn on power at the circuit breaker or fuse box. Test the lamps.
Easy Install Wiring Harness Components

Image 2: Components of the Satco Ballast Bypass Wiring Harness. This image illustrates the individual lamp holders and the main wiring connections for an easy installation process.

5. Иштөө нускамалары

Once the Satco 80-2629 Four Light Ballast Bypass Wiring Harness is correctly installed and connected to compatible LED T8 lampс, лamps will operate by simply turning on the power switch to the fixture. There are no additional operating controls on the harness itself.

6. Техникалык тейлөө

The Satco 80-2629 wiring harness requires minimal maintenance. It contains no user-serviceable parts. To ensure continued safe operation:

  • Periodically inspect the wiring and connections for any signs of wear, damage, or loosening.
  • Ensure the fixture remains dry and free from excessive dust or debris.
  • Before any inspection or cleaning, always disconnect power to the fixture at the circuit breaker.

7. Кыйынчылыктарды

Эгерде светодиод лamps do not illuminate after installation, consider the following:

  • Кубат жок: Check the circuit breaker to ensure power is restored to the fixture.
  • Бошоң байланыштар: Disconnect power and re-check all wiring connections within the fixture and to the harness. Ensure they are secure.
  • Туура эмес Л.amp Түрү: Verify that the installed lampлар ballast bypass (direct wire) LED T8 lamps. This harness is not compatible with fluorescent lamps же LED lamps that require a ballast.
  • Faulty LED Lamp: LEDди сынап көрүңүз lamps in another compatible fixture if possible, or try a new LED lamp.
  • Incorrect Wiring for LED Lamp: Some ballast bypass LED T8 lamps require power to one end and neutral to the other. Ensure your wiring configuration matches the requirements of your specific LED T8 lamps.

8. Техникалык шарттар

Модель номери: 80-2629
Өндүрүүчү: Сатко
Колдонмо: Four Light Ballast Bypass for Linear LED T8 Lamps
Кубат булагы: Corded Electric (Fixture Supply)
Элемент Салмагы: 10 фунт (Note: This may refer to shipping weight or packaging, actual harness is lighter)
Продукциянын өлчөмдөрү: 10 x 10 x 10 дюйм (Note: This may refer to packaging dimensions, actual harness is flexible)
Лампанын түрү: LED (Ballast Bypass T8)

9. Кепилдик жана колдоо

For warranty information and technical support regarding the Satco 80-2629 Four Light Ballast Bypass Wiring Harness, please contact the manufacturer directly. Refer to the product packaging or the official Satco webучурдагы байланыш маалыматтары жана кепилдик шарттары үчүн сайтты караңыз.

Warranty Description from product data: Contact manufacturer for warranty information.

© 2023 Satco. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.