Tektronix MSO22 2-BW-100
Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope
User Manual
Introduction
This manual provides essential information for the safe and efficient operation of your Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope. This instrument is designed for precise measurement and analysis of electronic signals, featuring a 100 MHz bandwidth and 2 analog channels.
Негизги өзгөчөлүктөр төмөнкүлөрдү камтыйт:
- Analog input channels: 2 inputs
- Өткөрүү жөндөмдүүлүгү: 100 МГц
- Sample rate: 2.5 GS/s Half channels; 1.25 GS/s All channels
- Record length: 10 Mpoints per channel
- Vertical resolution: 8 bits ADC; Up to 16 bits in high-resolution mode
Орнотуу жана Байланыштар
Before operating the oscilloscope, ensure it is placed on a stable, level surface with adequate ventilation. Connect the power cord to the instrument and a grounded AC outlet.

Figure 1: Front panel of the Tektronix MSO22 2-BW-100 Oscilloscope, showing the display, control knobs, buttons, and input connectors (Inputs 1, 2, Aux In, AFG/Aux Out).
Киргизүү байланыштары
- Analog Inputs (1, 2): Connect your probes to these BNC connectors for signal acquisition.
- Aux In: Auxiliary input for external trigger or other signals.
- AFG/Aux Out: Output for the Arbitrary Function Generator or auxiliary signals.
Күйгүзүү
Press the power button located on the front panel to turn on the instrument. Allow a few moments for the system to boot up.
Иштөө нускамалары
This section outlines the basic steps for operating the oscilloscope to capture and analyze waveforms.
Basic Waveform Capture
- Зондду туташтырыңыз: Attach a compensated probe to one of the analog input channels (e.g., Input 1).
- Circuit менен туташуу: Зонддун учун чынжырдагы сыноо чекитине, ал эми жерге туташтыргычты чынжырдын жерге туташтыргычына туташтырыңыз.
- Автоматтык түрдө коюу: басыңыз Auto-Set button (if available, common on oscilloscopes) to automatically adjust vertical and horizontal settings for a stable display.
- Вертикалдык масштабды тууралоо: колдонуу Vertical Scale knob to adjust the volts per division, controlling the amplitude of the waveform on the screen.
- Горизонталдык масштабды тууралоо: колдонуу Horizontal Scale knob to adjust the seconds per division, controlling the time base of the waveform.
- Триггерди тууралоо: колдонуу Триггер деңгээли үндү жөндөө үчүн баскычtage level at which the oscilloscope captures the waveform, ensuring a stable display.
Өлчөө функциялары
The MSO22 2-BW-100 offers various automated measurement functions. Access these through the on-screen menu system. Common measurements include Peak-to-Peak Voltage, Frequency, Period, and Rise/Fall Time.
Техникалык тейлөө
Туура тейлөө осциллографыңыздын узак мөөнөттүү иштешин жана тактыгын камсыз кылат.
Тазалоо
- Сырткы беттерин жумшак менен сүртүңүз, гamp кездеме. Абразивдүү тазалагычтарды же эриткичтерди колдонбоңуз.
- Ensure no liquid enters the instrument.
- Clean the display screen with a soft, lint-free cloth specifically designed for electronic displays.
Калибрлөө
For optimal performance, periodic calibration by qualified service personnel is recommended. Refer to the official Tektronix service manual for calibration procedures and intervals.
Проблемаларды чечүү
Бул бөлүмдө сиз кабылышы мүмкүн болгон жалпы маселелерди чечүү жолдору каралган.
- Дисплей жок:
- Ensure the power cord is securely connected and the instrument is powered on.
- Check the brightness and contrast settings of the display.
- Туруксуз толкун формасы:
- Adjust the trigger level and trigger source settings.
- Verify the probe compensation is correct.
- Check for proper grounding of the probe and the circuit under test.
- Сигнал табылган жок:
- Ensure the probe is correctly connected to the input channel and the circuit.
- Check the input coupling (AC/DC/GND) and vertical scale settings.
- Verify the signal source is active.
If problems persist, contact Tektronix customer support.
Техникалык шарттар
Detailed technical specifications for the Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope.
| Өзгөчөлүк | Спецификация |
|---|---|
| Модель номери | MSO22 2-BW-100 |
| Аналогдук киргизүү каналдары | 2 киргизүү |
| өткөрүү жөндөмдүүлүгү | 100 МГц |
| Sample Rate (Half Channels) | 2.5 GS/s |
| Sample Rate (All Channels) | 1.25 GS/s |
| Record Length | 10 Mpoints per channel |
| Vertical Resolution | 8 bits ADC; Up to 16 bits in high-resolution mode |
| Өндүрүүчү | Tektronix |
| Дата биринчи жеткиликтүү | 17-июнь, 2022-жыл |
Кепилдик жана колдоо
Tektronix products are designed for reliability and performance. For information regarding product warranty, please refer to the warranty statement included with your purchase or visit the official Tektronix webсайт.
For technical support, service, or additional documentation, please contact Tektronix customer service or visit their official support portal. Ensure you have your product model number (MSO22 2-BW-100) and serial number ready when contacting support.
Онлайн ресурстар: www.tek.com