Introduction
This manual provides instructions for the installation, operation, and maintenance of the Opengear CM8100 Console Server. The CM8100 series is designed to provide secure out-of-band management for network and server infrastructure, enabling remote access and control even during primary network outages.
Key features of the CM8100 Console Server include:
- 16, 32, or 48 port serial console server with Smart Out-of-Band™ capabilities.
- Support for Data Center and Enterprise Network automation with Python and Docker.
- Embedded physical security via TPM 2.0 module.
- Dual power supplies for redundancy and independent monitoring.
- Integrated environmental temperature monitoring.
Орнотуу жана орнотуу
This section guides you through the physical installation and initial setup of your CM8100 Console Server.
Аппаратты таңгактан чыгаруу
Бардык компоненттерди кутудан кылдаттык менен чыгарыңыз. "Кутуда эмне бар" бөлүмүндө саналган нерселердин бардыгы бар экенин жана бузулбаганын текшериңиз.
Сүрөт: алдыңкы view of the Opengear CM8100 Console Server, showing the red and black chassis, Opengear logo, model number, and dual power inlets on the right side.
Стойкага орнотуу
The CM8100 Console Server is designed for standard 19-inch rack installation.
- Attach the two rack ears to the sides of the console server using the provided M4 screws.
- Secure the console server into the rack using the four M5x15mm rack screws and M5mm caged nuts. Ensure the device is level and securely fastened.
Power Connection
The CM8100 features dual power supplies for redundancy.
- Connect the two A/C power cables to the power inlets on the rear of the console server.
- Connect the other ends of the power cables to independent power sources for redundancy.
- Verify that the power indicator LEDs on the front panel illuminate, indicating successful power-up.
Network Connection
Connect the console server to your network for management access.
- Connect an Ethernet cable from your network switch to the primary network port on the console server.
- (Optional) Connect a second Ethernet cable to the secondary network port for network redundancy.
Сериялык порт туташуу
Connect your managed devices (servers, network devices) to the serial ports on the CM8100.
- Identify the serial ports on the rear of the console server.
- Use appropriate serial cables (e.g., the provided CAT5 patch cable with DB9F-RJ45 rollover serial adapter) to connect your devices to the CM8100 serial ports.
- Note the port numbers for future configuration.
Сүрөт: Арткы view of the Opengear CM8100 Console Server, displaying various network and serial console ports, along with dual power supply connections.
Операция
This section covers basic operation and initial access to the CM8100 Console Server.
Баштапкы мүмкүндүк
Access the console server for initial configuration via a direct serial connection or network connection.
Serial Console Access
- Connect a computer to the console server's dedicated console port using a serial cable.
- Configure your terminal emulation software (e.g., PuTTY, Tera Term) with the following settings: 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control.
- Power on the CM8100. The boot process will display on your terminal.
- Log in using the default credentials (refer to the Quick Start Guide for default username and password).
Network Access (Web Интерфейс)
Once the device has an IP address (either DHCP assigned or manually configured via serial console), you can access the web интерфейс.
- ачуу а web browser and enter the IP address of the CM8100.
- Каттоо маалыматыңызды колдонуп кириңиз.
- From web interface, you can configure serial ports, network settings, user accounts, and other system parameters.
Туташкан түзмөктөрдү башкаруу
The CM8100 allows you to connect to the console of your attached devices.
- Сериялык консолго кирүү: From web interface or command-line interface (CLI), select the desired serial port to establish a connection to the attached device.
- Out-of-Band Management: Utilize the Smart OOB™ features to access and manage devices even when the primary network is down.
Техникалык тейлөө
Regular maintenance ensures optimal performance and longevity of your CM8100 Console Server.
Орнотулган программаны жаңыртуу
Periodically check the Opengear website for firmware updates. Keeping the firmware current provides new features, bug fixes, and security enhancements.
- Download the latest firmware image from the official Opengear support portal.
- Access the CM8100 web интерфейс.
- Navigate to the firmware update section (typically under System > Firmware).
- Жаңы микропрограмманы жүктөп алуу жана орнотуу үчүн экрандагы көрсөтмөлөрдү аткарыңыз. Жаңыртуу процессинде түзмөктү өчүрбөңүз.
Тазалоо
Keep the console server clean to prevent dust buildup, which can affect cooling.
- Аппараттын сыртын сүртүү үчүн жумшак, кургак чүпүрөктү колдонуңуз.
- Вентиляция тешиктери тоскоолдуктардан таза болушун камсыз кылыңыз.
- Суюк тазалоочу каражаттарды түз эле түзмөктүн үстүндө колдонбоңуз.
Экологиялык эске алуулар
Ensure the operating environment meets the recommended conditions.
- Maintain proper airflow around the device.
- Keep the device within specified temperature and humidity ranges.
Проблемаларды чечүү
This section provides solutions to common issues you might encounter with the CM8100 Console Server.
Күч жок
- Белги: Power indicator LEDs are off, device does not respond.
- Чечим: Verify that both A/C power cables are securely connected to the device and to active power outlets. Check power sources and circuit breakers.
Кирүү мүмкүн эмес Web Интерфейс
- Белги: Web browser cannot connect to the CM8100 IP address.
- Чечим:
- Verify the console server has power and is running.
- Confirm the network cable is properly connected to an active network port.
- Check the IP address configuration of the CM8100 (via serial console if necessary).
- Ensure your computer is on the same network or has a route to the CM8100's IP address.
- Temporarily disable any firewalls on your computer to rule out interference.
No Serial Console Connection to Managed Device
- Белги: Unable to establish a serial connection to a device connected to the CM8100.
- Чечим:
- Verify the serial cable connection between the CM8100 port and the managed device.
- Ensure the correct serial cable type (e.g., rollover, straight-through) is used for the specific device.
- Check the serial port configuration on the CM8100 (baud rate, data bits, parity, stop bits, flow control) matches the settings of the managed device.
- Confirm the managed device is powered on and functioning correctly.
Техникалык шарттар
| Өзгөчөлүк | Деталь |
|---|---|
| Бренд | Opengear |
| Сериялар | CM8100 Console Server |
| Модель номери | CM8116 |
| Элемент Салмагы | 8.63 фунт |
| Продукциянын өлчөмдөрү (LxWxH) | 19.5 x 16.5 x 3.5 дюйм |
| Өндүрүүчү | Opengear |
| Биринчи жеткиликтүү | 16-февраль, 2023-жыл |
Кутуда эмне бар
The following items are included with your Opengear CM8100 Console Server:
- CM8100 Console Server
- Rack Mount Kit
- 2 x Rack Ears with Six M4 Screws
- 4 x M5mm Caged Nuts
- 4 x M5x15mm Rack Screws
- 1 x CAT5 Patch Cable 6'
- 1 x DB9F-RJ45 Rollover Serial Adapter
- 2 x A/C Power Cables
- Quick Start Guide
- Lighthouse Insert