EVURU 2W-25B EPDM

EVURU 2/2 DN25 SS Electric Water Valve Instruction Manual

Model: 2W-25B EPDM

1. Киришүү

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your EVURU 2/2 DN25 Stainless Steel Electric Water Valve. This valve is a normally closed, direct-acting solenoid valve designed for controlling the flow of water, gas, or liquid in various applications.

Please read this manual thoroughly before installation and operation to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2. Коопсуздук маалыматы

ЭСКЕРТҮҮ: Бул коопсуздук көрсөтмөлөрүн аткарбоо мүлккө зыян келтирүүгө, оор жаракат алууга же өлүмгө алып келиши мүмкүн.

  • Always disconnect power before installing, servicing, or cleaning the valve.
  • тtage supply matches the valve's specified voltage (e.g., AC220V, DC12V). Incorrect voltage can damage the valve or cause electrical hazards.
  • Installation should be performed by qualified personnel in accordance with local electrical and plumbing codes.
  • Do not exceed the maximum working pressure specified for the valve.
  • Ensure the media (water, gas, liquid) and its temperature are within the valve's specified limits.
  • Орнотуу жана тейлөө учурунда тиешелүү жеке коргонуу шаймандарын (ЖКК) кийиңиз.
  • Avoid exposing the valve to corrosive environments or extreme temperatures outside its operating range.

3. Продукт бүтүп калдыview

The EVURU 2/2 DN25 SS Electric Water Valve is a robust solenoid valve constructed from Stainless Steel 304, designed for reliable flow control. It features a 1-inch pipe size (DN25) and is available with BSP or NPT threads. The valve operates as normally closed, meaning it remains closed when de-energized and opens when energized.

Assembled EVURU 2/2 DN25 SS Electric Water Valve with black solenoid coil and red wires.

Figure 1: Assembled EVURU 2/2 DN25 SS Electric Water Valve. This image shows the complete valve unit, including the stainless steel body, the black solenoid coil, and the red electrical wires.

4. Орнотуу жана орнотуу

4.1 Орнотууга чейинки текшерүүлөр

  • Verify that the valve specifications (voltage, pressure, media, temperature) match your application requirements.
  • Inspect the valve for any visible damage from shipping.
  • Ensure the piping system is clean and free of debris that could obstruct valve operation.

4.2 Механикалык орнотуу

  1. Turn off the main power supply and shut off the fluid flow to the installation area.
  2. Identify the inlet and outlet ports on the valve body. Flow direction is typically indicated by an arrow on the valve body.
  3. Apply appropriate thread sealant (e.g., PTFE tape or pipe dope) to the pipe threads.
  4. Thread the valve onto the pipes, ensuring a tight, leak-free connection. Do not overtighten.
  5. Mount the valve in a position that allows for easy access for maintenance and inspection. The solenoid coil should ideally be in an upright position to prevent accumulation of debris and ensure proper operation.

4.3 Электрдик туташуу

  1. Электр кубаты өчүрүлгөнүн текшериңиз.
  2. Connect the valve's electrical wires to the appropriate power source. Refer to the voltage specified on the solenoid coil.
  3. Кыска туташууларды же электр коркунучтарын болтурбоо үчүн бардык электр туташууларынын бекем жана тийиштүү түрдө изоляциялангандыгын текшериңиз.
  4. If applicable, connect the ground wire according to local electrical codes.
Disassembled EVURU 2/2 DN25 SS Electric Water Valve showing body, coil, and nut.

Figure 2: Disassembled EVURU 2/2 DN25 SS Electric Water Valve components. This image displays the main stainless steel valve body, the separate solenoid coil, and the retaining nut, illustrating how the coil attaches to the valve stem.

5. Иштөө нускамалары

The EVURU 2/2 DN25 SS Electric Water Valve is a normally closed (N/C) valve, meaning it is closed by default when no power is applied to the solenoid coil.

  1. To Open the Valve: Apply the specified electrical voltage to the solenoid coil. The coil will energize, lifting the plunger and opening the valve, allowing fluid to flow.
  2. To Close the Valve: Disconnect the electrical voltage from the solenoid coil. The coil will de-energize, and the plunger will return to its closed position, stopping the fluid flow.

Ensure that the system pressure and fluid temperature remain within the valve's specified operating limits during operation.

6. Техникалык тейлөө

Regular maintenance helps ensure the longevity and reliable operation of your valve.

  • Мезгилдүү текшерүү: Regularly check for any signs of leaks around the valve body and connections. Inspect the electrical wiring for damage or loose connections.
  • Тазалоо: If the valve is operating in an environment with particulate matter, periodic cleaning of the internal components may be necessary. Always disconnect power and depressurize the system before disassembling the valve.
  • Мөөрдү алмаштыруу: Over time, the EPDM seals may wear out. If leaks occur or the valve fails to seal properly, the seals may need to be replaced. Refer to Figure 2 for component identification.
  • Катушканы текшерүү: Ensure the solenoid coil is free from excessive heat, moisture, or physical damage.

Note: For complex repairs or internal component replacement, it is recommended to consult a qualified technician or the manufacturer.

7. Кыйынчылыктарды

Көйгөй Мүмкүн себеп Чечим
Клапан күйгүзүлгөндө ачылбайт.
  • No power to the coil.
  • Туура эмес томtage.
  • Coil damaged or burnt out.
  • Debris obstructing plunger.
  • Excessive pressure differential.
  • Электр менен камсыздоону жана байланыштарды текшериңиз.
  • Ырды текшерүүtage matches valve specification.
  • Катушканы алмаштырыңыз.
  • Disassemble and clean valve internals.
  • Ensure operating pressure is within limits.
Клапан электр энергиясы өчүрүлгөндө жабылбайт.
  • Debris lodged in valve seat.
  • Damaged or worn seal.
  • Spring failure.
  • Disassemble and clean valve internals.
  • Мөөрлөрдү алмаштырыңыз.
  • Replace valve or internal components.
Leakage from valve body or connections.
  • Loose pipe connections.
  • Damaged or worn seals.
  • Cracked valve body.
  • Tighten connections, reapply thread sealant.
  • Мөөрлөрдү алмаштырыңыз.
  • Клапанды алмаштырыңыз.
Coil overheating.
  • Туура эмес томtage.
  • Continuous operation beyond duty cycle (if applicable).
  • Internal short circuit.
  • Ырды текшерүүtage.
  • Ensure valve is suitable for continuous duty or adjust operation.
  • Катушканы алмаштырыңыз.

8. Техникалык шарттар

Модел 2W-25B EPDM
Түтүктүн өлчөмү 1 inch (DN25)
Thread Type BSP, NPT
Медиа Water, Gas, Liquid
Type Normally Closed (N/C), Direct Acting
Working Pressure (Water, Air) 0-10 бар
Working Pressure (Oil) 0-7 бар
Тtage Параметрлер AC240V, AC220V, AC120V, AC110V, AC24V, DC24V, DC12V (±10% tolerance)
Материал Дат баспас болот 304
Мөөр материалы EPDM
Medium Temperature (EPDM) -5…120°C (23…248°F)
Элемент Салмагы 1 Grams (Note: This value seems unusually low and may be a placeholder. Refer to actual product for accurate weight.)

9. Кепилдик маалыматы

Specific warranty details for the EVURU 2/2 DN25 SS Electric Water Valve are not provided in this manual. For information regarding product warranty, please refer to the purchase documentation, contact your retailer, or visit the official EVURU webсайт.