RWRAPS REX-C100
RWRAPS REX-C100 Digital PID Temperature Controller User Manual
Model: REX-C100
Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your RWRAPS REX-C100 Digital PID Temperature Controller. This device is designed for precise temperature control in various industrial and laboratory applications, featuring universal input and a 0-20mA current output.
Негизги өзгөчөлүктөрү
- Кош дисплей: Simultaneous display of set temperature (SV) and process temperature (PV) in Celsius or Fahrenheit.
- Универсалдуу киргизүү: Supports 10 types of thermocouples (K, E, S, R, J, T, B, WRe3-WRe25) and RTD inputs (Pt100, Cu50).
- PID башкаруу: Advanced PID control mode with auto-tune function for optimal parameter setting.
- Учурдагы чыгаруу: 0-20mA current output for precise control.
- Компакт дизайн: 1/16 DIN size (48mm x 48mm x 110mm) for space-efficient installation.
- Кеңири колдонуу: Suitable for kilns, furnaces, ovens, incubators, and various industrial temperature control systems.
Техникалык мүнөздөмөлөр
| Киргизүү түрү | TC: K, E, S, R, J, T, B, WRe3-WRe25; RTD: Pt100, Cu50 |
| Киргизүү диапазону | K (-200~+1300°C), S (-50~+1600°C), R (-50~+1600°C), T (-200~400°C), E (-200~900°C), J (-200~1200°C), B (350~1800°C), Pt100 (-99.9~600.0°C or -200~+600°C), Cu50 (-50~150°C) |
| Дисплей | Dual line, Four digits, °C/°F selectable |
| Display Resolution | 1°C, 1°F, or 0.1°C, 0.1°F (with Pt100) |
| Тактык | ±0.5% or ±1 unit of full input range |
| Башкаруу режими | PID, On-Off |
| Чыгуу режими | Current: 0-20mA (Non-linear output: 0mA when PV is close to SV, 20mA when PV varies significantly) |
| Ойготкуч | Upper-limit bias alarm |
| Электр камсыздоо | 85~260VAC / 50~60Гц |
| Энергияны керектөө | <2 Ватт |
| Өлчөмдөр | 48mm x 48mm x 110mm (1/16 DIN) |
| Элемент Салмагы | 10.6 унция |
Орнотуу жана орнотуу
1. Front Panel Overview

The front panel (Figure 1) provides the primary interface for monitoring and adjusting the controller's settings. The upper display (PV) shows the current measured temperature, while the lower display (SV) shows the target temperature. The buttons allow for navigation through menus and parameter adjustments.
2. Wiring Terminals

Figure 2 illustrates the rear wiring terminals. Ensure all connections are made securely to prevent operational issues. Refer to the wiring diagram for correct terminal assignments.
3. Электр схемасы

The wiring diagram (Figure 3) is crucial for proper installation. Follow these guidelines:
- Power Supply (Terminals 1 & 2): Connect your 100-240VAC, 50/60Hz power source here.
- Current Output (Terminals 3 & 4): Connect your control device requiring 0-20mA input. Terminal 3 is positive (+), Terminal 4 is negative (-).
- Alarm Output (Terminals 6 & 7): Connect your alarm indicator or relay here.
- Sensor Input (Terminals 8, 9, 10):
- For RTD (e.g., Pt100): Connect to terminals 8, 9, and 10.
- For Thermocouple (TC): Connect to terminals 9 and 10. Ensure correct polarity.
Маанилүү: Always ensure power is disconnected before performing any wiring to prevent electric shock.
Иштөө нускамалары
1. Power On and Initial Display
Upon powering on, the controller will display the current process value (PV) on the upper red display and the set value (SV) on the lower green display. Ensure the sensor is correctly connected and functioning.
2. Максаттуу температураны (SV) коюу
- басыңыз SET button once. The SV display will begin to flash.
- колдонуу Up (▲) жана Төмөн (▼) arrow buttons to adjust the target temperature.
- колдонуу Сол оң (◀ / ▶) arrow buttons to move the cursor for faster adjustment of individual digits.
- басыңыз SET button again to confirm the new SV and exit the setting mode.
3. Auto-Tune Function (AT)
The auto-tune function automatically calculates optimal PID parameters for your specific system, ensuring stable and accurate temperature control.
- Set your desired target temperature (SV) as described above.
- басып, кармап туруңуз SET button for approximately 3-5 seconds until the 'AT' indicator light begins to flash.
- The controller will now cycle through heating and cooling to determine the system's characteristics. This process may take some time depending on your system's thermal mass.
- Once auto-tuning is complete, the 'AT' indicator light will stop flashing and remain off. The controller will then operate with the newly calculated PID parameters.
Эскертүү: It is recommended to perform auto-tuning whenever the system's thermal characteristics change significantly (e.g., new heater, different load).
4. Advanced Parameter Settings
For advanced users, the controller offers individually programmable control parameters (P, I, D, control period, digital filter coefficient, etc.). Accessing and adjusting these parameters typically involves pressing and holding the SET button for an extended period (e.g., 5-10 seconds) to enter the parameter menu. Refer to the detailed parameter list in the full technical manual for specific codes and ranges. Incorrect settings can lead to unstable control.
Техникалык тейлөө
- Тазалоо: Keep the controller's front panel clean using a soft, dry cloth. Avoid abrasive cleaners or solvents.
- Экологиялык шарттар: Ensure the operating environment is within the specified temperature and humidity ranges to prolong the life of the device.
- Зымдарды текшерүү: Бардык зымдардын туташууларынын бекемдигин жана эскирүү же дат басуу белгилерин мезгил-мезгили менен текшерип туруңуз.
Проблемаларды чечүү
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Дисплей жок/Өчүрүү | Электр менен камсыздоо жок; Туура эмес зымдар | Check power connections (Terminals 1 & 2); Verify power source is active. |
| Фотоэлектрдик дисплейде "HHHH" же "LLLL" көрсөтүлөт | Sensor open circuit; Sensor short circuit; Incorrect sensor type selected; Sensor out of range | Check sensor wiring; Replace faulty sensor; Verify sensor type setting matches installed sensor; Ensure temperature is within sensor's measurable range. |
| Temperature unstable/Overshoot/Undershoot | PID parameters not optimized; Incorrect control mode | Perform Auto-Tune (AT function); Ensure PID control mode is selected for precise control. |
| Чыгаруу активдештирилбей жатат | Wiring error; Output device fault; SV not reached | Check output wiring (Terminals 3 & 4); Test external output device; Ensure PV is below SV (for heating) or above SV (for cooling) to trigger output. |
Колдоо жана кепилдик
For technical assistance or warranty inquiries, please contact your vendor or the manufacturer, RWRAPS. Please have your model number (REX-C100) and purchase details available when contacting support.
Ask a question about this manual