PUSR DR134

PUSR USR-DR134 RS485 to Ethernet Serial Device Server Instruction Manual

Модели: DR134

Brand: PUSR

1. Киришүү

The PUSR USR-DR134 is a compact, industrial-grade serial device server designed for transparent data transmission between RS485 serial ports and Ethernet networks. It functions as a Modbus Gateway, converting Modbus RTU to Modbus TCP, and supports various protocols including MQTT, TCP, UDP, and HTTP for flexible integration into industrial automation and IoT systems. Its ultra-small DIN-rail design allows for easy installation in space-constrained environments.

2. Негизги өзгөчөлүктөрү

  • Ultra-small size serial server device with one serial port.
  • Realizes transparent transmission between RS485 and Ethernet ports.
  • Supports advanced features such as timeout restart, DHCP, DNS, heartbeat packet, and registration packet.
  • Modbus Gateway functionality: Connects to PLC, SCADA systems, or private servers for local or remote monitoring.
  • Industrial-grade design with hardware watchdog for reliable, non-downtime operation in harsh environments.
  • Easy integration and installation with DIN-rail and locating hole mounting.
PUSR USR-DR134 device with a lipstick for size comparison, highlighting its compact form factor.

Image: The PUSR USR-DR134 serial device server, shown next to a lipstick to illustrate its compact "lipstick" size. This highlights its suitability for space-constrained installations.

Diagram highlighting the PUSR USR-DR134's features: ultra-small size, RS485/232 to Ethernet conversion, and transparent transmission.

Сүрөт: An overview диаграмма showcasing the USR-DR134's core features, including its ultra-small form factor, RS485/RS232 to Ethernet conversion capability, and transparent data transmission.

3. Орнотуу жана орнотуу

3.1 Физикалык орнотуу

The USR-DR134 is designed for easy installation using DIN-rail mounting or locating hole mounting.

  1. Securely attach the device to a standard DIN-rail by snapping it into place.
  2. Alternatively, use the locating holes to mount the device to a surface with appropriate screws.
  3. Оптималдуу иштеши үчүн аппараттын айланасында туура желдетүүнү камсыз кылыңыз.
Diagram showing the PUSR USR-DR134 mounted on a DIN rail, illustrating easy installation.

Image: The USR-DR134 device mounted on a DIN-rail, demonstrating its compact size and simple installation method.

3.2 Зымдарды туташтыруу

Connect the RS485 serial device to the serial port terminals on the USR-DR134.

Connect an Ethernet cable from the device's Ethernet port to your network switch or router.

Provide power to the device using the designated power input terminals. Refer to the device labeling for correct voltage жана полярдуулук.

Close-up of the PUSR USR-DR134 showing its ports and LED indicators.

Сүрөт: деталдуу view of the USR-DR134's ports and LED indicators, including POW (Power), WORK, COM (Serial Communication), and LINK (Ethernet Link).

3.3 Баштапкы конфигурация

The device can be configured via its web interface or dedicated configuration software.

  1. Connect your computer to the same local network as the USR-DR134.
  2. Use the provided configuration tool or access the device's default IP address in a web браузер.
  3. Configure network parameters (IP address, subnet mask, gateway) and serial port settings (baud rate, data bits, parity, stop bits).
  4. Set up the desired operating mode (e.g., TCP Client, TCP Server, UDP, Modbus Gateway).

4. Иштөө нускамалары

4.1 Ачык берүү

The USR-DR134 facilitates bidirectional transparent data transmission. Data sent to the serial port is forwarded to the Ethernet network, and data received from the Ethernet network is sent to the serial port.

Diagram illustrating bidirectional transparent transmission from serial device to Ethernet network via the USR-DR134.

Image: A diagram illustrating the bidirectional transparent transmission function, showing how serial devices communicate with an Internet/LAN network through the USR-DR134.

4.2 Modbus Gateway Functionality

The device supports Modbus RTU to Modbus TCP conversion, enabling Modbus RTU devices to communicate with Modbus TCP masters over an Ethernet network.

  • Configure the device as a Modbus RTU master or slave, and a Modbus TCP master or slave as required by your application.
  • It supports Modbus autonomous polling and JSON autonomous reporting for efficient data acquisition.
Diagram showing Modbus RTU to Modbus TCP conversion via the device.

Image: Illustration of Modbus RTU to Modbus TCP conversion, showing how the USR-DR134 bridges communication between Modbus devices and a monitoring system, including Modbus polling and RTU/JSON reporting.

4.3 MQTT/TCP/UDP/HTTP Protocols

The USR-DR134 supports various network protocols for versatile data communication:

  • MQTT: Ideal for IoT applications, enabling lightweight messaging to MQTT brokers.
  • TCP/UDP: Standard network protocols for reliable (TCP) or fast (UDP) data transfer.
  • HTTP: үчүн мүмкүнчүлүк берет web-based communication and data reporting.
Diagram showing the device acting as an MQTT Gateway, connecting to cloud services like AWS and Thingsboard.

Image: The USR-DR134 configured as an MQTT Gateway, demonstrating its ability to connect to cloud platforms like PUSR Cloud, AWS, and Thingsboard for topic distribution and custom modes.

5. Техникалык тейлөө

  • Keep the device clean and free from dust and debris to ensure proper ventilation.
  • Бардык кабелдик туташуулардын бекемдигин текшерүү үчүн мезгил-мезгили менен текшерип туруңуз.
  • Өндүрүүчүгө кайрылыңыз website for any available firmware updates to enhance performance and security.
  • In industrial environments, ensure the operating temperature and humidity remain within the specified ranges.

6. Кыйынчылыктарды

6.1 Power LED (POW) is Off

Чечим: Электр кубаты менен камсыздоонун туташуусун текшерип, ал туура көлөмдү камсыздайтtage (e.g., 5-36V DC) and polarity. Verify the power source is active.

6.2 Link LED is Off or Flashing Incorrectly

Чечим: Verify the Ethernet cable is securely connected to both the device and the network switch/router. Check the network cable for damage. Ensure the network port on the switch is active.

6.3 COM LED is Off or Flashing Incorrectly

Чечим: Check the RS485 serial connection to the external device. Verify the serial port settings (baud rate, data bits, parity, stop bits) on the USR-DR134 match those of the connected serial device.

6.4 No Data Transmission

  • Confirm all physical connections (power, Ethernet, serial) are correct and secure.
  • Verify the device's IP address and network settings are correctly configured and accessible from your network.
  • Check the operating mode settings (e.g., TCP Client, TCP Server) and ensure they match your application's requirements.
  • For Modbus applications, ensure Modbus RTU/TCP settings are correct, including slave IDs and register addresses.
  • If using advanced features like heartbeat or registration packets, ensure they are configured properly.

6.5 Түзмөк жооп бербейт

Чечим: If the device becomes unresponsive, try power cycling it. The built-in hardware watchdog should automatically restart the device in case of a system malfunction, ensuring continuous operation.

7. Техникалык шарттар

ӨзгөчөлүкDescription
БрендPUSR
Модель номериDR134
Аппараттык интерфейсEthernet, RS485
Data Link ProtocolEthernet
Маалыматтарды өткөрүү ылдамдыгы100 Мегабит секундасына
Шайкеш түзмөктөрDesktop (for configuration), PLCs, SCADA systems, Serial Devices
Бирдик саны1.0 Сан
ТүсWhite (with green terminals)

8. Кепилдик жана колдоо

Кепилдик: The PUSR USR-DR134 comes with a 2-year warranty. Please retain your proof of purchase for warranty claims.

Колдоо: For technical assistance, troubleshooting, or further inquiries, please visit the official PUSR webсайтка же кардарларды тейлөөгө кайрылыңыз.

Visit the PUSR Store on Amazon

9. Продукт бүтүп калдыview Video

Видео: расмий продукт бүттүview of the PUSR DR134/DR132 serial device servers, highlighting their ultra-small DIN-rail design, RS485/RS232 to Ethernet bidirectional transmission, Modbus RTU to TCP conversion, and industrial-grade reliability. The video also demonstrates the compact size and ease of installation.

Ask a question about this manual