MokerLink 4x2.5G PoE + 2x10G SFP Managed

MokerLink 4 Port 2.5G PoE Managed Switch with 2 Port 10G SFP+ Slot User Manual

Model: 4x2.5G PoE + 2x10G SFP Managed

1. Продукт бүтүп калдыview

The MokerLink 4 Port 2.5G PoE Managed Switch is designed to provide high-speed network connectivity and Power over Ethernet (PoE) capabilities. It features four 2.5 Gigabit Ethernet ports with PoE support and two 10 Gigabit SFP+ slots for high-bandwidth uplinks. This managed switch offers advanced Layer 2 features for network control and optimization, all within a compact, fanless metal casing.

MokerLink 4 Port 2.5G PoE Managed Switch

Figure 1.1: MokerLink 4 Port 2.5G PoE Managed Switch

Key features of the MokerLink 2.5G PoE Managed Switch

Figure 1.2: ашыкview of Switch Features including 2.5Gbps Ports, 10G SFP+ Ports, PoE Support, and L2 Management

Негизги өзгөчөлүктөрү:

  • 4 x 2.5 Gigabit Ethernet Ports: Compliant with IEEE802.3bz (2.5G) standard, supporting 10/100/1000M/2.5G adaptive speeds.
  • 2 x 10 Gigabit SFP+ Ports: Compatible with 1G/2.5G/10G SFP modules (modules not included).
  • Web GUI Managed: Supports device/port status query and various Layer 2 configurations such as VLAN, LACP, QoS, security, multicast, and MAC address table management.
  • PoE колдоосу: Ports 1-4 support IEEE802.3af/at PoE, with a maximum of 30W per port and a total power budget of 78W.
  • желдеткичсиз дизайн: Ensures quiet operation and lower energy consumption.
  • Бышык металл Casing: Ишенимдүү коргоону жана натыйжалуу жылуулукту таратууну камсыз кылат.
  • Чагылгандан коргоо: Integrated protection to safeguard the device from electrical surges.

2. Пакеттин мазмуну

Сураныч, таңгагыңыздын ичиндегисин текшериңиз. Эгерде кандайдыр бир буюмдар жок болсо же бузулуп калса, дароо сатуучуга кайрылыңыз.

  • MokerLink 4 Port 2.5G PoE Managed Switch
  • Кубаттуу адаптер
  • Колдонуучунун Колдонмосу (бул документ)

3. Аппараттык сүрөттөлүш

Front Panel

The front panel of the switch includes the Ethernet ports, SFP+ ports, and LED indicators for status monitoring.

Front panel layout with ports and indicators

Figure 3.1: Front Panel Configuration

  • 2.5Gbps PoE Ports (1-4): RJ45 ports supporting 10/100/1000Mbps and 2.5Gbps speeds, with Power over Ethernet capabilities.
  • 10G SFP+ Uplink Ports (5-6): Slots for 1G/2.5G/10G SFP/SFP+ modules for high-speed fiber or copper connections.
  • Калыбына келтирүү баскычы: Short press to restart the device. Press and hold for 5 seconds to restore factory default settings.

LED көрсөткүчтөрү

ИндикаторСтатусDescription
СистемаONSystem is working correctly
SFP көрсөткүчүONLink connected, normal
PWR (кубат)ONТүзмөк күйгүзүлгөн
PWR (кубат)ӨЧҮРҮҮТүзмөк өчүк
2.5Gbps Port (Left LED)Ачык күрөң2.5Gbps link speed
2.5Gbps Port (Right LED)Жашыл10/100/1000Mbps link speed

4. Орнотуу жана орнотуу

4.1 Физикалык орнотуу

The switch features a mini size and durable metal casing, allowing for flexible placement options such as desktop use or wall-mounting.

  • Иш тактада жайгаштыруу: Place the switch on a stable, flat surface with adequate ventilation.
  • Дубалга орнотуу: Use appropriate screws and anchors (not included) to secure the switch to a wall. Ensure the mounting location is sturdy and allows for proper cable management.

4.2 Кубат туташтыруу

Connect the provided power adapter to the DC input port on the switch and then plug it into a standard electrical outlet. The PWR LED indicator will illuminate when the switch receives power.

4.3 Тармактык байланыштар

Connect your network devices to the switch using appropriate cables.

  • 2.5G PoE Ports (1-4): Use Cat5e, Cat6, or Cat6a Ethernet cables to connect devices such as IP cameras, wireless access points, IP phones, or other network devices. These ports will automatically detect and provide PoE power to compatible devices.
  • 10G SFP+ порттору (5-6): Insert compatible 1G, 2.5G, or 10G SFP/SFP+ modules into these slots. Then, connect fiber optic or DAC cables from the modules to your high-speed network devices or other switches.
Connecting various devices to the MokerLink switch

4.1-сүрөт: Мисample Network Connections with 2.5G and 10G Devices

4.4 Баштапкы Web Башкаруу мүмкүнчүлүгү

To configure the switch, access its web- негизделген башкаруу интерфейси:

  1. Connect a computer directly to any of the switch's Ethernet ports.
  2. Configure your computer's IP address to be in the same subnet as the switch's default IP address (e.g., if the switch is 192.168.2.1, set your computer to 192.168.2.X, where X is not 1, with a subnet mask of 255.255.255.0).
  3. ачуу а web браузерди иштетип, коммутатордун демейки IP дарегин киргизиңиз: 192.168.2.1
  4. Демейки кирүү маалыматын киргизиңиз:
    Колдонуучунун аты: админ
    Купуя сөз: админ
  5. Upon successful login, you will access the switch's web management interface. It is recommended to change the default password for security.
Screenshot of the MokerLink switch web интерфейс

Figure 4.2: Accessing the Web Башкаруу интерфейси

5. Operating Instructions (Web Менеджмент)

The web management interface provides comprehensive control over the switch's functions. Below are some of the key Layer 2 features you can configure:

Бүттүview of L2 management features

Figure 5.1: Lite L2 Management Features

5.1 VLAN (Виртуалдык локалдык тармак)

VLANs allow you to segment your network into smaller, isolated broadcast domains. This enhances security and network performance by controlling traffic flow. The switch supports 802.1Q Tag-негизделген VLANдар.

Example of 802.1Q Tag-based VLAN configuration

Figure 5.2: 802.1Q Tag-based VLAN Configuration Example

5.2 QoS (Тейлөө сапаты)

QoS allows you to prioritize network traffic, ensuring that critical applications (like voice or video) receive sufficient bandwidth and experience minimal delay. This helps reduce packet loss and latency on the network.

QoS prioritization for different traffic types

Figure 5.3: QoS Prioritization Example

5.3 LACP (Link Aggregation Control Protocol)

LACP allows you to bundle multiple physical links into a single logical link, increasing bandwidth and providing link redundancy. This is useful for connecting to servers or other switches.

5.4 STP/RSTP (Spanning Tree Protocol/Rapid Spanning Tree Protocol)

STP/RSTP prevents network loops, which can cause broadcast storms and network instability. These protocols ensure a loop-free topology by blocking redundant paths.

5.5 IGMP Snooping (Internet Group Management Protocol)

IGMP Snooping optimizes multicast traffic by forwarding it only to ports where multicast receivers are present, preventing unnecessary flooding of multicast packets across the network.

5.6 Jumbo Frame Support

The switch supports Jumbo Frames up to 10Kbytes, which can improve network efficiency for large data transfers by reducing the number of packets processed.

6. PoE Functionality

The MokerLink switch provides Power over Ethernet (PoE) on ports 1-4, adhering to IEEE 802.3af/at standards. This allows compatible devices to receive both data and power over a single Ethernet cable.

PoE+ IEEE 802.3af/at support diagram

Figure 6.1: PoE+ IEEE 802.3af/at Support

  • Стандарттык шайкештик: IEEE 802.3af (up to 15.4W per port) and IEEE 802.3at (PoE+, up to 30W per port).
  • Per Port Power: Each PoE port can deliver up to 30W.
  • Total Power Budget: The switch has a total PoE power budget of 78W. Ensure the total power consumption of all connected PoE devices does not exceed this limit.
  • Эскертүү: This switch does not support passive 24V PoE. Only connect devices compatible with IEEE 802.3af/at standards.

7. Техникалык тейлөө

The MokerLink switch is designed for low maintenance and reliable operation.

  • желдеткичсиз дизайн: The fanless design eliminates moving parts, reducing the risk of mechanical failure and ensuring quiet operation. This also minimizes dust accumulation inside the device.
  • Бышык металл Casing: The robust metal casing provides protection and aids in passive heat dissipation.
  • Тазалоо: Periodically clean the exterior of the switch with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are clear of obstructions.
  • Курчап турган чөйрө: Operate the switch within its specified temperature and humidity ranges to ensure optimal performance and longevity. Avoid placing it in direct sunlight or near heat sources.

8. Кыйынчылыктарды

If you encounter issues with your MokerLink switch, refer to the following troubleshooting tips:

  • Кубат жок: Ensure the power adapter is securely connected to both the switch and a working power outlet. Check the PWR LED indicator.
  • Портто шилтеме жок: Verify that the Ethernet or SFP+ cable is properly connected at both ends. Check the link status LEDs on the switch and the connected device. Ensure the connected device is powered on and functioning correctly.
  • Web Interface Unreachable:
    • Confirm your computer's IP address is in the same subnet as the switch (default: 192.168.2.1).
    • Try pinging the switch's IP address (192.168.2.1).
    • If the switch was previously configured with DHCP client mode and lost its IP, it might revert to a default or unassigned state. Consider setting a static IP on the switch for stability.
    • If the interface is unresponsive, try restarting the switch by briefly pressing the Reset button.
  • Random Factory Reset: Some users have reported instances of the switch randomly factory resetting. If this occurs, reconfigure the switch using the default IP (192.168.2.1) and settings. Ensure the switch is in a stable environment and has a consistent power supply.
  • Аткаруу маселелери:
    • Check cable quality; use Cat5e/6/6a for 2.5G and appropriate fiber/DAC for 10G SFP+ connections.
    • Verify that connected devices support the desired speeds (e.g., 2.5G or 10G).
    • Review QoS settings if specific traffic types are experiencing issues.
  • Device Failure: If the switch powers on but no traffic passes, or it becomes unconfigurable, the device may have failed. In such cases, contact MokerLink support for assistance.
  • Заводдук жөндөөлөрдү калыбына келтирүү: If you forget the login credentials or encounter persistent configuration issues, press and hold the Reset button for 5 seconds until the LEDs flash, then release. This will restore the switch to its factory default settings.

9. Техникалык шарттар

ӨзгөчөлүкСпецификация
Модель номери4x2.5G PoE + 2x10G SFP Managed
Порттардын саны4 x 2.5G PoE, 2 x 10G SFP+
Interface TypePoE, SFP
PoE стандартыIEEE802.3af/at
Ар бир порт үчүн максималдуу PoE күчү30 Вт
Жалпы PoE кубаттуулугу бюджети78 Вт
Маалыматтарды өткөрүү ылдамдыгы60 Gigabits Per Second (Backplane Bandwidth)
Пакетти жөнөтүү ылдамдыгы44.64 Mpps
Jumbo Frame10 Кбайт
MAC дарек столунун көлөмү4K
Иштин материалыМеталл
МуздатууКүйөрмансыз
Тtage24 Volts (Input for power adapter)
Элемент Салмагы2.16 фунт
Пакеттин өлчөмдөрү8.74 x 8.43 x 2.13 дюйм
Шайкеш түзмөктөрCamera, Desktop, Gaming Console, Server

10. Кепилдик жана колдоо

MokerLink products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please contact MokerLink customer support through their official channels or the retailer from whom the product was purchased.

Кепилдик дооматтары үчүн сатып алганыңыздын далилин сактап коюңуз.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.