The Brrnoo RD72-DC-12V Infinite Cycle ON Off Relay Module is designed to provide precise, adjustable delay timing for various applications. This module allows for continuous cycling of a connected device, turning it ON and OFF according to user-defined time intervals. It features separate adjustments for ON time and OFF time, an external start/stop function, and low power consumption, making it suitable for industrial and scientific control systems.

2. Продукт бүтүп калдыview

The RD72-DC-12V module integrates a relay, control circuitry, and user-adjustable components on a compact PCB. Key components include power input terminals, relay output terminals, time adjustment potentiometers, and time unit selection DIP switches.

Labeled diagram of the Brrnoo RD72-DC-12V relay module showing components and settings.

2.1-сүрөт: Labeled diagram of the RD72-DC-12V module. This image highlights the 'RUN TIME' (ON time) and 'STOP TIME' (OFF time) potentiometers, their corresponding 'Sec.' (seconds) and 'Min.' (minutes) DIP switches, the module power input, and the relay output terminals (NO, COM, NC). It also indicates the green light for 'ON' and red light for 'OFF' status, and the external wiring start button connection point.

Жогорудан төмөн view of the Brrnoo RD72-DC-12V relay module.

2.2-сүрөт: Жогорудан төмөн view of the RD72-DC-12V module. This image provides a clear perspective of the module's layout, showing the blue relay, terminal blocks, potentiometers, and DIP switches.

3. Техникалык шарттар

ӨзгөчөлүкСпецификация
ТtageDC 12V
Энергияны керектөө1 Вттан аз
Output TypePassive output (dry contact), 1 group Normally Open (NO) + Normally Closed (NC)
Максималдуу чыгаруу ток10A
Өмүр эстафетасы100,000 XNUMX операция
Убакыт диапазону0.5 секунд - 1000 мүнөт
Убакыттын тактыгыMaximum value of range * 0.001 (1000-level resolution)
External Start Button InputPassive switch input (self-resetting button required). Can also use external voltage: <2V (low level), >2V (high level). Max input 30V.
Продукциянын өлчөмдөрү4.33 x 3.15 x 1.18 дюйм
Продукт Салмагы0.99 унция

4. Орнотуу

4.1 Кубат туташтыруу

Connect a DC 12V power supply to the designated DC input terminals on the module. Ensure correct polarity: '+' for positive and '-' for negative. The module's power consumption is less than 1W.

4.2 Жүктөө Байланыш

The module provides passive relay output (dry contact). This means the relay acts as a switch and does not supply power to the load. Connect your device's power circuit through the relay terminals:

  • COM (жалпы): Connect one side of your load's power circuit here.
  • ЖОК (Негизде ачык): Connect the other side of your load's power circuit here if you want the circuit to be жабык (power ON) when the relay is activated.
  • NC (Нормалдуу жабык): Connect the other side of your load's power circuit here if you want the circuit to be ачык (power OFF) when the relay is activated. This terminal is generally not connected for typical ON/OFF cycling applications.

Ensure the connected load does not exceed 10A.

4.3 External Start/Stop Button Connection

An external passive switch (self-resetting button) can be connected to the designated terminals to start and stop the infinite cycle. Alternatively, an external voltage can be used: a low level (below 2V) acts as OFF, and a high level (above 2V, maximum 30V) acts as ON.

Side view of the Brrnoo RD72-DC-12V relay module showing terminal blocks.

4.1-сүрөт: Side view of the RD72-DC-12V module, illustrating the terminal blocks for power input and relay output connections.

5. Иштөө нускамалары

The module operates in an infinite cycle mode once started, with the relay switching ON and OFF according to the set time intervals.

5.1 Setting ON Time (RUN TIME)

  1. Locate the potentiometer labeled "RUN TIME".
  2. Adjust the potentiometer clockwise to increase the ON duration, and counter-clockwise to decrease it.
  3. Use the adjacent DIP switches to select the time unit:
    • Төмөнкүгө коюу "Sec." for seconds (range 0.5 to 1000 seconds).
    • Төмөнкүгө коюу "Min." for minutes (range 0.5 to 1000 minutes).

5.2 Setting OFF Time (STOP TIME)

  1. Locate the potentiometer labeled "STOP TIME".
  2. Adjust the potentiometer clockwise to increase the OFF duration, and counter-clockwise to decrease it.
  3. Use the adjacent DIP switches to select the time unit:
    • Төмөнкүгө коюу "Sec." for seconds (range 0.5 to 1000 seconds).
    • Төмөнкүгө коюу "Min." for minutes (range 0.5 to 1000 minutes).

5.3 Ишке киргизүү/токтотуу функциясы

  • Once the module is powered and times are set, press the external start button (or apply a high-level voltage) to initiate the infinite cycle.
  • The green indicator light will turn ON when the cycle starts.
  • To stop the cycle, press the external button again (or remove the high-level voltage). The red indicator light will remain ON, indicating the module is stopped.

6. Техникалык тейлөө

The Brrnoo RD72-DC-12V module is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure longevity:

  • Модулду чаңдан жана таштандыдан таза жана таза кармаңыз.
  • Модулду нымдуулукка же өтө жогорку температурага дуушар кылбаңыз.
  • Мезгил-мезгили менен бардык зымдарды байланыштарды текшерип, алардын коопсуз экендигин текшерип туруңуз.
  • Do not attempt to modify the internal circuitry, as this may damage the module and void any potential warranty.

7. Кыйынчылыктарды

If you encounter issues with your RD72-DC-12V module, consider the following:

  • Модуль күйбөйт: Verify the DC 12V power supply is correctly connected and providing the specified voltage. Check polarity.
  • Реле которулбай жатат: Ensure the ON and OFF times are set correctly and the module has been started via the external button. Check the load connections (COM, NO, NC).
  • Туура эмес убакыт: Double-check the potentiometer settings and the DIP switch selections for seconds or minutes for both RUN TIME and STOP TIME.
  • External start/stop not working: Confirm the external button is a self-resetting type and properly wired. If using external voltage, ensure it meets the <2V (low) and >2V (high) thresholds and does not exceed 30V.
  • Load not receiving power: Confirm the load itself is functional and its power source is active. Ensure the relay output terminals are correctly wired to the load's circuit.

8. Коопсуздук маалыматы

Сураныч, төмөнкү коопсуздук чараларын сактаңыз:

  • Always disconnect power before making any wiring changes to the module or connected devices.
  • Ensure all wiring is correctly insulated and secured to prevent short circuits.
  • Максималдуу көлөмдөн ашпаңызtage (DC 12V) or current (10A) ratings for the module and its relay output.
  • This module is an electronic component; handle it with care to avoid damage from static electricity or physical impact.
  • If you are unsure about any wiring or operation, consult a qualified electrician or technician.

© 2024 Brrnoo. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.