1. Киришүү
Thank you for choosing the Wiltec 1200W Submersible Water Pump. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your pump. Please read these instructions carefully before use and retain them for future reference.
This submersible pump is designed for pumping water from wells, tanks, and other water sources. It features a powerful 1200W motor, a maximum flow rate of 6000 L/h, a maximum discharge height of 40 meters, and an immersion depth of up to 12 meters. Integrated safety features include a float switch, dry-run protection, and a thermoregulator to ensure reliable performance and longevity.
2. Коопсуздук нускамалары
ЭСКЕРТҮҮ: Бул коопсуздук көрсөтмөлөрүн аткарбоо электр тогуна урунууга, өрткө, оор жаракат алууга же өлүмгө алып келиши мүмкүн.
- Always disconnect the pump from the power supply before performing any maintenance, cleaning, or when not in use.
- электр менен жабдууну камсыз кылуу voltage matches the specifications on the pump's rating label.
- Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
- Never lift or carry the pump by its power cord. Use the designated handle or a sturdy rope attached to the pump's lifting eye.
- Балдарды жана уруксаты жок адамдарды операциялык аймактан алыс кармаңыз.
- The pump is designed for pumping clean water. Do not use it for flammable, corrosive, or explosive liquids.
- Ensure the pump is fully submerged during operation to prevent dry running, which can cause damage. The integrated dry-run detector provides additional protection.
- Do not operate the pump in swimming pools or areas where people are in the water.
- Protect the pump from frost. Drain all water from the pump and hoses if there is a risk of freezing temperatures.
- The built-in thermoregulator protects the motor from overheating. If the pump shuts off automatically, allow it to cool down before restarting.
3. Продукт бүтүп калдыview
The Wiltec 1200W Submersible Water Pump is constructed with a durable plastic and stainless steel main body, ensuring corrosion resistance and portability. It features a robust motor and advanced safety mechanisms for reliable water transfer.

Сүрөт 3.1: A person lowering the Wiltec Submersible Water Pump into a body of water. The image highlights the pump's capability to achieve a 40-meter discharge height and its general use as a submersible pump.

Сүрөт 3.2: А деталдуу view of the Wiltec Submersible Water Pump, showcasing анын бекем кара casing, integrated handle, and the float switch mechanism attached to the side.
4. Техникалык шарттар
Refer to the table below for detailed technical specifications of the Wiltec 1200W Submersible Water Pump.

Сүрөт 4.1: This diagram illustrates the product dimensions (500mm height, 165mm diameter) and key performance data, including a 10m cable length and a performance curve showing flow rate versus discharge height.
| Өзгөчөлүк | Спецификация |
|---|---|
| Модель номери | 65343 |
| Күч | 1200 Вт |
| Макс. Flow Rate | 6000 л/саат |
| Max. Discharge Height | 40 м |
| Макс. Батуу тереңдиги | 12 м |
| Кабелдин узундугу | 10 м |
| Макс. Бөлүкчөлөрдүн өлчөмү | 1 мм |
| Min. Water Level for Suction | 34 мм |
| Коргоо түрү | IPX8 |
| Материал | Plastic (Polypropylene), Stainless Steel |
| Элемент Салмагы | 9 кг |
| Иштөө температурасы диапазону | 1°C - 35°C |
5. Орнотуу жана орнотуу
5.1 Connecting the Discharge Hose
The pump is compatible with various hose diameters. Ensure a secure connection to prevent leaks and maintain optimal flow.

Сүрөт 5.1: This image illustrates the pump's compatibility with different hose diameters, specifically 31mm and 25mm, and shows the necessary adapters for connection.
- Select a discharge hose of appropriate diameter (e.g., 25mm or 31mm) for your application.
- Attach the hose connector to the pump's discharge outlet.
- Secure the hose to the connector using a hose clamp (not included) to ensure a watertight seal.
- Position the discharge end of the hose to direct water to the desired location.
5.2 Positioning the Pump
- Lower the pump into the water source using a sturdy rope attached to the pump's lifting eye. Do not use the power cable.
- Ensure the pump is placed on a stable, level surface at the bottom of the water source, or suspended so it does not rest directly on sediment.
- The pump must be fully submerged during operation. The maximum immersion depth is 12 meters.
- Ensure the float switch has sufficient space to move freely and activate/deactivate the pump based on water levels.
6. Иштөө нускамалары
6.1 Кубат туташтыруу
Once the pump is correctly positioned and the discharge hose is connected, plug the pump into a grounded electrical outlet. Ensure the outlet is protected by a Residual Current Device (RCD) for safety.
6.2 Automatic Operation (Float Switch)
The pump is equipped with a float switch for automatic operation. When the water level rises, the float switch will lift, turning the pump on. As the water level drops, the float switch will lower, turning the pump off. Adjust the float switch cable length to set the desired on/off water levels.

Сүрөт 6.1: This graphic depicts the two operating modes: 'Smart Sensor' (automatic via float switch) and 'Manual Operation', showing the float switch mechanism.
6.3 Кол менен иштетүү
For continuous pumping, the float switch can be secured in an upward position. This will keep the pump running regardless of the water level. Абайлаңыз: When operating in manual mode, closely monitor the water level to prevent dry running, which can damage the pump. The dry-run detector will provide protection, but manual oversight is recommended.
6.4 Dry-Run Protection and Thermoregulator
The pump features a dry-run detector that automatically shuts off the pump if the water level becomes too low, preventing damage. Additionally, a built-in thermoregulator protects the motor from overheating. If the pump stops unexpectedly, allow it to cool down for approximately 15-20 minutes before attempting to restart it.

Сүрөт 6.2: This image highlights the pump's efficient water suction capability, processing particles up to 1mm, and indicates a minimum water level of 34mm for operation.
7. Техникалык тейлөө
Regular maintenance ensures the longevity and optimal performance of your Wiltec submersible pump.
7.1 Тазалоо
- Before cleaning, always disconnect the pump from the power supply.
- Rinse the pump with clean water after each use, especially if pumping dirty water, to prevent sediment buildup.
- Inspect the intake screen for blockages. Remove any debris carefully.
- Check the float switch for free movement and clean any obstructions.
7.2 Сактоо
- If the pump will not be used for an extended period, or during freezing temperatures, drain all water from the pump and hoses.
- Насосту кургак, үшүк тийбеген жерде сактаңыз.
- Coil the power cable neatly to prevent damage.
8. Кыйынчылыктарды
This section provides solutions to common problems you might encounter with your submersible pump.
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Насос иштебейт | Электр энергиясы жок Float switch not activated Ашыкча ысып кетүүдөн коргоо иштетилди Импеллер бөгөттөлгөн | Электр байланышын жана сактагычты текшериңиз Ensure float switch is free to move and in 'ON' position Allow pump to cool down (approx. 15-20 min) Disconnect power, clean intake screen and impeller |
| Pump runs but no water is discharged or flow is low | Air in pump/hose Чыгаруучу түтүк бүктөлүп же тыгылып калган Intake screen blocked Суунун деңгээли өтө төмөн Насос толугу менен сууга түшө элек | Ensure pump is fully submerged and allow air to escape Түтүктү текшерип, тазалаңыз Disconnect power, clean intake screen Ensure water level is above minimum operating level Reposition pump to ensure full submersion |
| Иш учурунда насос токтойт | Ашыкча ысып кетүүдөн коргоо иштетилди Dry-run protection activated Float switch deactivated (water level too low) | Насосту муздатыңыз Check water level, ensure pump is submerged Check water level, adjust float switch if necessary |
| Ашыкча ызы-чуу же титирөө | Насос туруктуу эмес Impeller damaged or blocked | Насостун туруктуу бетте турганын текшериңиз Электр кубатын өчүрүңүз, текшериңиз жана дөңгөлөктү тазалаңыз |
9. Ар тараптуу колдонмолор
The Wiltec 1200W Submersible Water Pump is suitable for a wide range of water transfer tasks, making it a versatile tool for both domestic and professional use.

Сүрөт 9.1: This image displays several common applications for the pump, including emptying a rain barrel, garden irrigation, maintaining a garden pond, and dewatering a flooded cellar.
- Dewatering: Quickly remove water from flooded basements, construction sites, or other areas.
- Garden Irrigation: Utilize water from rain barrels, ponds, or wells for watering gardens and lawns.
- Pond Maintenance: Circulate or empty water from garden ponds.
- Water Transfer: Move water between tanks, containers, or other sources.
10. Кепилдик жана колдоо
For warranty information, technical support, or spare parts, please contact Wiltec customer service or refer to the purchase documentation. Keep your proof of purchase for any warranty claims.