Introduction
This manual provides essential information for the proper use, installation, and maintenance of your Resvent iBreeze Humidifier Chamber. This chamber is designed as a replacement or spare part for compatible Resvent iBreeze CPAP, APAP, and BiPAP devices, ensuring optimal humidification during therapy.
Шайкештик
The Resvent iBreeze Humidifier Chamber is compatible with the following Resvent iBreeze CPAP, APAP, and BiPAP series machines:
- CPAP Series: 20C, 20C Pro
- APAP Series: 20A, 20A Pro
- BiPAP Series: 25S, 25A, 25ST, 25STA, 30ST, 30STA
Орнотуу жана орнотуу
Before installing the humidifier chamber, ensure your CPAP/APAP/BiPAP device is turned off and unplugged from the power source.
- Remove Existing Chamber (if applicable): Gently slide out the old humidifier chamber from the main device unit. Refer to your main device's user manual for specific instructions if needed.
- Inspect New Chamber: Examine the new Resvent iBreeze Humidifier Chamber for any visible damage or defects.
- Fill with Distilled Water: Open the chamber and fill it with distilled water up to the "MAX" fill line. Do not overfill. Using distilled water helps prevent mineral buildup and prolongs the life of the chamber and humidifier.

Image: The Resvent iBreeze Humidifier Chamber showing the clear water reservoir and the "MAX" fill line indicator.
- Insert Chamber: Carefully slide the filled humidifier chamber into the humidifier slot of your Resvent iBreeze device until it clicks securely into place. Ensure it is fully seated to prevent leaks.

Image: A Resvent iBreeze CPAP machine with the humidifier chamber partially inserted, demonstrating the installation process. An inset circle highlights the chamber being filled.
- Туташуу кубаты: Plug your device back into the power source.
Операция
Once the humidifier chamber is installed and filled, the humidification function is controlled via your main Resvent iBreeze device. Refer to your device's user manual for detailed instructions on adjusting humidity levels and settings.
- Күнүмдүк суунун алмашуусу: Always use fresh distilled water for each therapy session. Do not reuse water from previous sessions.
- Суунун деңгээлин көзөмөлдөө: Periodically check the water level in the chamber. If the water level is low, refill it with distilled water.
- Колдонгондон кийин бош: After each use, it is recommended to empty any remaining water from the chamber to prevent bacterial growth.
Тейлөө жана тазалоо
Regular cleaning of your humidifier chamber is crucial for hygiene and optimal performance. Clean the chamber daily or after each use.
- Бөлүп салуу: Carefully remove the humidifier chamber from the device. Disassemble the chamber by separating its components (e.g., lid, reservoir). The chamber features a removable tank for easy cleaning.

Image: The Resvent iBreeze Humidifier Chamber disassembled, showing the clear water tank separated from its outer casing, ready for cleaning.
- Жуу: Wash all components with warm water and a mild dish soap. Use a soft brush if necessary to remove any residue.
- Чайкоо: Самын калдыктарын толугу менен кетирүү үчүн бардык компоненттерди агын суу астында жакшылап чайкаңыз.
- Disinfect (Weekly): For weekly disinfection, soak the components in a solution of one part white vinegar to three parts distilled water for 30 minutes, or use a CPAP cleaning solution as directed by the manufacturer. Rinse thoroughly afterward.
- Кургак: Allow all parts to air dry completely on a clean surface before reassembling. Do not place in direct sunlight.

Image: The Resvent iBreeze Humidifier Chamber fully reassembled, showing its compact form factor and clear water level indicator.
- Кайра чогултуу: Once dry, reassemble the chamber components.
Маанилүү эскертүүлөр:
- Do not wash the humidifier chamber in a dishwasher unless explicitly stated in your main device's manual.
- Do not use harsh chemicals, bleach, or alcohol-based cleaners, as these can damage the chamber material.
- Replace the humidifier chamber if it shows signs of wear, cracking, discoloration, or if mineral buildup cannot be removed.
Проблемаларды чечүү
Most issues related to the humidifier chamber are often due to improper installation or maintenance. If you experience problems, consider the following:
- No Humidity/Low Humidity:
- Check if the chamber is filled with water up to the MAX line.
- Ensure the chamber is correctly seated in the device.
- Verify that the humidifier function is enabled and set to the desired level on your main device.
- Confirm you are using distilled water; tap water can cause mineral buildup affecting performance.
- Суу агып кетиши:
- Ensure the chamber is not overfilled.
- Check that the chamber is properly assembled and securely inserted into the device.
- Inspect the chamber for cracks or damage. If damaged, replace the chamber.
- Өзгөчө жыт:
- Clean the chamber thoroughly as per the maintenance instructions.
- Ensure you are using fresh distilled water daily.
- If the odor persists, the chamber may need replacement.
For issues not resolved by these steps, refer to your main Resvent iBreeze device's user manual or contact Resvent customer support.
Техникалык шарттар
| Өзгөчөлүк | Деталь |
|---|---|
| Продукт аты | Resvent iBreeze Humidifier Chamber |
| Модел | iBreeze |
| Шайкештик | Resvent iBreeze CPAP, APAP, BiPAP Series (20C/20C Pro, 20A/20A Pro, 25S/25A/25ST/25STA/30ST/30STA) |
| Кубаттуулугу | 290 mL (to Max fill line) |
| Өлчөмдөрү (болжол менен) | 4.4"D x 4.2"W x 4.5"H |
| Салмагы (бош) | 10 унция |
| Өзгөчө өзгөчөлүк | Алынуучу танк |
| Материал | Medical-grade plastic (typically) |
Кепилдик жана колдоо
This humidifier chamber is typically covered under the warranty of your main Resvent iBreeze CPAP/APAP/BiPAP device, or by a separate limited warranty from the manufacturer. Please refer to the warranty information provided with your original device or contact the manufacturer, Resvent, or your product supplier for specific warranty terms and support inquiries.