Hilitand XH-3002 Electronic Temperature Controller User Manual

Model: XH-3002 110-220V 1500W

1. Киришүү

This manual provides detailed instructions for the installation, operation, and maintenance of the Hilitand XH-3002 Electronic Temperature Controller. This device is designed for precise temperature regulation in various applications such as aquariums, incubation systems, home brewing, and more. Please read this manual thoroughly before use to ensure proper function and safety.

Hilitand XH-3002 Electronic Temperature Controller with features listed

Сүрөт 1.1: Бүттүview of the Hilitand XH-3002 Electronic Temperature Controller highlighting its LED display, accurate measurement, auto temperature regulation, and high-quality material.

2. Коопсуздук маалыматы

  • Ensure the power supply matches the controller's specifications (110-220V for this model).
  • Аппаратты сууга же ашыкча нымдуулукка дуушар кылбаңыз.
  • Зымдарды туташтыруудан же техникалык тейлөө иштерин жүргүзүүдөн мурун электр кубатынан ажыратыңыз.
  • Балдар жетпеген жерде сактаңыз.
  • Эгерде түзмөк бузулгандай көрүнсө, аны колдонбоңуз.

3. Продукциянын өзгөчөлүктөрү

  • Колдонуунун кеңири спектри: Suitable for automatic irrigation, aquariums, fish tanks, home, and industrial applications.
  • Температураны так көзөмөлдөө: Control range of -50℃ to 110℃ with 0.1℃ precision.
  • Auto Start/Stop Function: Automatically regulates heating or cooling based on set temperatures.
  • Оңой орнотуу: Compact design (60x45x31mm) with M4 mounting holes.
  • Туруктуу курулуш: Solid ABS shell, LED display, and 10K temperature probe.

4. Пакеттин мазмуну

Пакетке төмөнкүлөр кирет:

  • 1 x Hilitand XH-3002 Electronic Temperature Controller
  • 1 x Temperature Probe (integrated)

Note: Other accessories shown in product images are not included unless specified.

5. Техникалык шарттар

ПараметрНарк
МоделXH-3002
Киргизүү көлөмүtage110-220V
Power Output1500 Вт
Өлчөө диапазону-50 градустан 110 градуска чейин
Control Precision0.1℃
Температура сенсору10K NTC Probe
Output Type10А Реле
Монтаждоо тешигиM4 (4мм)
Өлчөмдөр60мм x 45мм x 31мм
МатериалABS + Электрондук компоненттер
Dimensions of the Hilitand XH-3002 Temperature Controller

Image 5.1: Physical dimensions of the XH-3002 controller, showing measurements of 60mm, 45mm, and 73mm (including mounting tabs), with M4 bore diameter mounting holes.

6. Орнотуу жана зымдар

Before connecting, ensure the power source is disconnected. The controller has three sets of wires: Input, Output, and Probe.

  1. Кубат киргизүү: Connect the two red/black wires labeled 'INPUT' to your 110-220V AC power supply.
  2. Жүктөө чыгаруу: Connect the two yellow/black wires labeled 'OUTPUT' to the device you wish to control (e.g., heater, cooler). Ensure the load's power consumption does not exceed 1500W.
  3. Температура зонду: The black wire labeled 'PROBE' is the temperature sensor. Place the metal tip of the probe in the environment where temperature needs to be measured.
Wiring diagram for Hilitand XH-3002 Temperature Controller

Image 6.1: Wiring connections for the XH-3002 controller, showing input power, output load, and temperature probe connections.

7. Иштөө нускамалары

The controller features an LED display and three buttons: SET, Up (▲), and Down (▼).

Control panel of Hilitand XH-3002 with button functions and P-codes

Image 7.1: Front panel of the XH-3002 controller, indicating the display, output indicator light, SET button, Up button (short press to display 'start temp'), and Down button (short press to display 'stop temp').

7.1. Viewing Current Temperature Settings

  • Short press the ▲ (Up) button to display the starting temperature (P0).
  • Short press the ▼ (Down) button to display the stopping temperature (P1).

7.2. Setting Temperature Parameters (P-Codes)

To enter the parameter setting mode, press and hold the SET button for approximately 3 seconds. The display will show 'P0'. Use the ▲ and ▼ buttons to navigate through the P-codes (P0-P3). Press SET again to select a P-code and adjust its value using ▲ and ▼. Press SET again to confirm the setting and exit, or wait a few seconds for it to auto-save and exit.

  1. P0: Starting Temperature
    • Range: -50℃ to 110℃
    • Factory Setting: 25℃
    • This is the temperature at which the controller will activate the output (e.g., turn on a heater or turn off a cooler).
  2. P1: Stopping Temperature
    • Range: -50℃ to 110℃
    • Factory Setting: 40℃
    • This is the temperature at which the controller will deactivate the output (e.g., turn off a heater or turn on a cooler).
  3. P2: Temperature Calibration
    • Range: -10℃ to 10℃
    • Factory Setting: 0℃
    • Use this to fine-tune the temperature reading if there is a known offset with a reference thermometer.
  4. P3: Delay Start
    • Диапазон: 0дөн 10 мүнөткө чейин
    • Factory Setting: 0 minutes
    • This sets a delay before the output activates after the temperature condition is met. Useful for protecting compressors in cooling systems.

7.3. Heating and Cooling Modes

  • Жылытуу режими: Set P0 (Start Temp) < P1 (Stop Temp). The output will activate when the temperature drops below P0 and deactivate when it reaches P1.
  • Муздатуу режими: Set P0 (Start Temp) > P1 (Stop Temp). The output will activate when the temperature rises above P0 and deactivate when it reaches P1.

8. Техникалык тейлөө

  • Тазалоо: Контроллердин бетин жумшак, кургак чүпүрөк менен сүртүңүз. Абразивдүү тазалоочу каражаттарды же эриткичтерди колдонбоңуз.
  • Пробка кам көрүү: Температура датчигинин таза жана так көрсөткүчтөр үчүн таштандылардан таза экенин текшериңиз. Зонддун кабелин ийип же бузуп албаңыз.
  • Текшерүү: Мезгил-мезгили менен бардык зымдарды байланыштарды текшерип, алардын коопсуз экендигин текшерип туруңуз.

9. Кыйынчылыктарды

КөйгөйМүмкүн себепЧечим
Дисплей өчүкЭлектр менен камсыздоо жок же зымдар туура эмес туташтырылган.Электр туташууларын текшерип, үнүн туура чыгарыңызtage.
Температураны көрсөтүү туура эмесDamaged probe or incorrect calibration (P2).Check probe for damage. Adjust P2 setting if necessary.
Чыгаруу иштетилбей/өчүрүлбөй жататIncorrect P0/P1 settings, P3 delay, or faulty wiring.Verify P0 and P1 settings for heating/cooling mode. Check P3 delay. Inspect output wiring.
"LLL" or "HHH" displayedProbe error (open circuit or short circuit) or temperature out of range.Check probe connection. Replace probe if damaged. Ensure temperature is within -50℃ to 110℃.

10. Кепилдик жана колдоо

For warranty information and technical support, please refer to the product's purchase documentation or contact the seller directly. Hilitand is committed to providing quality products and customer satisfaction.

© 2026 Hilitand. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.