AOPUTTRIVER AP-5000Y

AOPUTTRIVER AP-5000Y Hot Wire Anemometer Instruction Manual

Model: AP-5000Y

1. Киришүү

The AOPUTTRIVER AP-5000Y is a versatile hot wire anemometer designed for accurate measurement of wind speed, airflow (CFM/CMM), and temperature. Its retractable, 360° revolving probe allows for precise measurements in various environments, including tight spaces like HVAC ducts. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your device.

2. Кутуда эмне бар

  • AP-5000Y Hot Wire Anemometer Unit
  • Канвас сумка
  • Instruction Manual
  • Маалымат кабели (С түрү)
Contents of the AP-5000Y package including the anemometer, canvas bag, manual, and data cable.

Image: Contents of the AP-5000Y package, showing the anemometer, canvas bag, instruction manual, and Type-C data cable.

3. Орнотуу

Before initial use, it is crucial to connect the internal battery and fully charge the device.

  1. Батареяны туташтыруу:
    Locate the battery compartment on the back of the device. Use a small screwdriver to remove the battery cover. Connect the battery line interface to the corresponding port inside the compartment. Ensure a secure connection.
    Steps for connecting the battery: 1. Remove battery cover, 2. Connect battery cable, 3. Tighten cover.

    Image: Detailed steps for connecting the internal battery. This involves removing the battery cover with a screwdriver, connecting the battery cable, and then securing the cover.

  2. Батареянын капкагын бекитиңиз:
    Once the battery is connected, carefully place the battery back into its compartment and tighten the cover using the screwdriver.
  3. Аппаратты заряддоо:
    Connect the provided Type-C data cable to the anemometer and a suitable USB power source. The device is powered by a 600mAh lithium-ion battery. The battery icon on the LCD will indicate charging status. Charge until the battery icon shows a full charge. Note: The device cannot be turned on while it is charging.

4. Иштөө нускамалары

4.1 Түзмөк бүттүview жана Controls

Diagram of the AP-5000Y anemometer showing the LCD screen, On/Off button, Mode button, Unit button, MAX/MIN/SET buttons, and the retractable probe with sensor protective cover.

Image: Labeled diagram of the AP-5000Y anemometer, highlighting the LCD screen, power button, mode selection, unit selection, data retention, and the retractable sensor probe with its protective cover.

  • Күйгүзүү/өчүрүү баскычы: Түзмөктү күйгүзүү же өчүрүү үчүн басыңыз.
  • MODE баскычы: Cycles through different measurement functions (Air Speed, Air Volume, Temperature).
  • UNIT баскычы: Changes the measurement units for the selected function (e.g., m/s, km/h, ft/min, knots, mph for wind speed; CFM/CMM for airflow; °C/°F for temperature).
  • МАКСИМАЛДУУ/МИН/ОРТОЧО баскычы: Toggles between maximum, minimum, and average values recorded during a measurement session.
  • SET баскычы: Used for data retention (data hold) and other settings.
  • LCD дисплей: Shows real-time measurements, units, battery status, and other indicators. Features a backlight for visibility in low-light conditions.

4.2 Өлчөөлөрдү алуу

  1. Күйгүзүү: Press the On/Off button to turn on the anemometer. The LCD display will illuminate.
  2. Режимди тандоо: басыңыз РЕЖИМ button to choose between wind speed, airflow, or temperature measurement.
  3. Бирдиктерди тандоо: басыңыз UNIT button to select your desired measurement units.
  4. Зондду даярдаңыз: Gently pull out the retractable probe to the desired length. Remove the sensor protective cover. The probe can be rotated and twisted 360 degrees for optimal positioning in various spaces.
    User holding the AP-5000Y anemometer with its retractable probe extended and bent to measure airflow in a duct.

    Image: A user demonstrating the use of the AP-5000Y anemometer with its flexible, retractable probe extended and bent to measure airflow inside a ventilation duct.

  5. Зондду жайгаштырыңыз: Place the sensor end of the probe directly into the airflow or area you wish to measure. Ensure the sensor is fully exposed to the flow for accurate readings.
  6. Өлчөөлөрдү окуу: Observe the real-time values on the LCD display. You can press the MAX / MIN / AVG баскычына view the maximum, minimum, or average readings during your measurement session.
  7. Дайындарды кармоо: басыңыз SET дисплейдеги учурдагы окууну тоңдоого баскыч. Бошотуу үчүн аны кайра басыңыз.
  8. Өчүрүү: After use, retract the probe and replace the sensor protective cover. Press the On/Off button to turn off the device. The anemometer also features an automatic power-off function to conserve battery.

Арткы жарыгы бар 4.3 LCD дисплей

The LCD display provides clear readings of wind speed, airflow, temperature, and humidity. It is equipped with a backlight for enhanced visibility in various lighting conditions. To activate or deactivate the backlight, refer to the specific instructions in the full user manual if not controlled automatically.

Comparison of the AP-5000Y LCD display in bright and dark environments, showing the effectiveness of the backlight.

Image: A comparison showing the AP-5000Y's LCD display in both a well-lit room and a dark environment, demonstrating the clarity provided by its backlight feature.

5. Техникалык тейлөө

  • Тазалоо: Wipe the device and probe with a soft, dry cloth. Do not use abrasive cleaners or solvents. The probe is waterproof and dustproof, but avoid submerging the main unit in liquids.
  • Сенсорго кам көрүү: Always replace the sensor protective cover when the probe is not in use to prevent damage to the delicate hot wire sensor.
  • Батареяга кам көрүү: Recharge the lithium-ion battery when the low battery indicator appears on the display. For long-term storage, ensure the battery is partially charged (around 50%) and store the device in a cool, dry place.
  • Сактагыч: Store the anemometer in its canvas bag to protect it from dust and physical damage.

6. Кыйынчылыктарды

КөйгөйМүмкүн себепЧечим
Түзмөк күйбөйтБатарея туташтырылган эмес же заряды жокEnsure the internal battery is properly connected (refer to Setup section). Charge the device using the Type-C cable.
Так эмес окууларIncorrect probe placement, wrong unit selected, sensor obstructionEnsure the probe's hot wire sensor is fully exposed to the airflow. Verify that the correct measurement mode and units are selected. Clean the sensor if necessary.
Дисплей бош же күңүртLow battery, backlight offRecharge the battery. Check if the backlight needs to be manually activated (refer to Operating Instructions).
Түзмөк заряддалбай жататCable issue, power source issueEnsure the Type-C cable is securely connected. Try a different USB power adapter or port.

7. Техникалык шарттар

ӨзгөчөлүкСпецификация
Аба ылдамдыгы диапазону0.1 ~ 30 м / с
Air Velocity Unitsм/с, км/саат, фут/мүн, түйүндөр, миль/саат
Абанын температурасы диапазону0 ~ 45 ° C (32 ~ 113 ° F)
Air Volume Range0 ~ 999900 m³/min (CFM/CMM)
Пробдун өлчөмү298.5 x 40.84 x 23.7 mm (retractable)
Батарея600mAh литий-иону
Заряддоо интерфейсиType-C
Өлчөмдөрү (Негизги бирдик)5.74 x 2.36 x 1.1 дюйм
Салмагы237 грамм
МатериалПластик
ДисплейАрткы жарык менен LCD
ӨзгөчөлүктөрRetractable 360° revolving probe, MAX/MIN/AVG, Data Hold, Auto Power-Off, Waterproof & Dustproof Probe

8. Кепилдик жана колдоо

For specific warranty information regarding your AOPUTTRIVER AP-5000Y Hot Wire Anemometer, please refer to the documentation included with your purchase or contact the seller directly. Warranty terms may vary based on region and retailer.

Should you encounter any issues or require technical assistance, please contact AOPUTTRIVER customer support through their official website or the retailer from whom you purchased the product. Please have your model number (AP-5000Y) and purchase details ready when contacting support.

Ask a question about this manual