This manual describes the assembly, installation, operation, and troubleshooting of the Hybrid Solar Inverter. Please read this manual carefully before installations and operations. Keep this manual for future reference.
1.2 Scope
This manual provides safety and installation guidelines as well as information on tools and wiring for the Hybrid Solar Inverter. This is a multi-function inverter/charger, combining functions of an inverter, solar charger, and battery charger to offer uninterruptible power support with a portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage ар кандай колдонмолорго негизделген.
1.3 Өзгөчөлүктөрү
- Pure sine wave solar inverter (on/off grid)
- Конфигурациялануучу киргизүү томtagЖК орнотуу аркылуу үй техникасы жана персоналдык компьютерлер үчүн электрондук диапазон
- LCD орнотуусу аркылуу тиркемелердин негизинде батарейканы кубаттоочу конфигурацияланган
- ЖК орнотуусу аркылуу өзгөрүлмө AC / Solar Charger приоритети
- Негизги Voltagе же генератордун күчү
- AC калыбына келтирилип жатканда, авто өчүрүп күйгүзүү
- Ашыкча жүктөө / Ашыкча температура / кыска туташуудан коргоо
- Батареяны оптималдаштыруу үчүн батареяны кубаттагычтын дизайны
- Муздак баштоо функциясы
- WiFi available for iOS and Android (optional)
- Inverter can run without battery
- Заводдук жөндөөлөргө бир баскыч менен калыбына келтирүү
- Камтылган литий батареясы автоматтык түрдө жандыруу
- Катаал чөйрө үчүн камтылган чаңга каршы комплект
- Кош чыгаруу



2. Коопсуздук нускамалары
ЭСКЕРТҮҮ: Бул бөлүмдө маанилүү коопсуздук жана иштетүү нускамалары камтылган. Бул колдонмону окуп чыгып, келечекте маалымат алуу үчүн сактаңыз.
- Аппаратты колдонуудан мурун, аппараттагы, батарейкалардагы жана ушул колдонмонун бардык тиешелүү бөлүмдөрүндөгү бардык нускамаларды жана эскертүү белгилерин окуп чыгыңыз.
- ЭСКЕРТҮҮ --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Агрегатты ажыратпаңыз. Тейлөө же оңдоо керек болгондо аны квалификациялуу тейлөө борборуна алып барыңыз. Туура эмес кайра чогултуу электр шок же өрт чыгуу коркунучуна алып келиши мүмкүн.
- Электр тогуна урунуу коркунучун азайтуу үчүн, тейлөө же тазалоодон мурун бардык зымдарды ажыратыңыз. Бирдикти өчүрүү бул коркунучту азайтпайт.
- ЭСКЕРТҮҮ – Бул аппаратты батарейка менен квалификациялуу кызматкерлер гана орното алышат.
- ЭЧ КАЧАН тоңуп калган батареяны заряддаңыз.
- For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Батареяларда же анын айланасында металл аспаптар менен иштөөдө өтө этият болуңуз. Учкун же кыска туташуу батареялары же башка электр бөлүктөрү үчүн аспапты түшүрүү потенциалдуу коркунучу бар жана жарылууга алып келиши мүмкүн.
- Сураныч, AC же DC терминалдарын ажыраткыңыз келсе, орнотуу процедурасын так аткарыңыз. Сураныч, чоо-жайын билүү үчүн бул колдонмонун ОРНОТУУ бөлүмүн караңыз.
- 150A сактагычтын бир бөлүгү батарейка менен камсыздоо үчүн ашыкча ток коргоо катары берилет.
- ЖЕРДЕШТИРУУ НУСКАМАСЫ -Бул инвертор/зарядкыч туруктуу жерге туташтырылган зымдар системасына туташтырылууга тийиш. Бул инверторду орнотуу үчүн жергиликтүү талаптарды жана эрежелерди сактоону унутпаңыз.
- ЭЧ КАЧАН AC чыгышына жана DC киришине кыска туташууга себеп болот. Туруктуу токтун кыска туташуулары болгондо электр тармагына туташтырбаңыз.
- Эскертүү!! Бул аппаратты квалификациялуу тейлөө кызматкерлери гана тейлей алышат. Эгерде каталарды жоюу таблицасында көрсөтүлгөндөн кийин дагы деле болсо, бул инверторду/зарядкычты техникалык тейлөө үчүн кайра жергиликтүү дилерге же тейлөө борборуна жөнөтүңүз.
3. Орнотуу жана орнотуу
3.1 Таңгактан чыгаруу жана текшерүү
Орнотуудан мурун, аппаратты текшериңиз. Пакеттин ичиндеги эч нерсе бузулбагандыгын текшериңиз. Пакеттин ичинде сиз төмөнкү нерселерди алышыңыз керек:
- X 1 бирдиги
- Колдонуучунун колдонмосу x 1

3.2 Даярдоо
Before connecting all wirings, please take off the bottom cover by removing two screws.
3.3 Агрегатты монтаждоо
Орнотууну тандоодон мурун төмөнкү пункттарды карап көрүңүз:
- Инверторду тез күйүүчү курулуш материалдарына орнотууга болбойт.
- катуу бетине орнотуу.
- ЖК дисплей ар дайым окулушу үчүн, бул инверторду көз деңгээлинде орнотуңуз.
- Жылуулукту таратуу үчүн абанын туура айлануусу үчүн болжол менен клирингге жол бериңиз. капталына 20 см жана болжол менен. 50 см жогору жана ылдый бирдиги.
- Оптималдуу иштешин камсыз кылуу үчүн айлана-чөйрөнүн температурасы 0°C жана 55°C ортосунда болушу керек.
- Сунушталган орнотуу позициясы дубалга вертикалдуу түрдө кармалышы керек.
- Жетиштүү жылуулук таркатылышына кепилдик берүү жана зымдарды алып салуу үчүн жетиштүү орун болушу үчүн диаграммада көрсөтүлгөндөй башка нерселерди жана беттерди сактаңыз.
WARNING: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two screws. It's recommended to use M6 screws.
3.4 Негизги системанын архитектурасы
The following illustration shows a basic application for this inverter/charger. It includes connections to a generator or utility, PV modules, and external battery packs to power home appliances.



3.5 Батареяны туташтыруу
ЭСКЕРТҮҮ: Коопсуздук жана эрежелерди сактоо үчүн, батарейка менен инвертордун ортосунда өзүнчө туруктуу токтун ашыкча ток коргоочусун орнотуу же ажыратуучу түзүлүштү орнотуу суралат. Айрым колдонмолордо ажыратуучу түзүлүштүн болушу суралбашы мүмкүн, бирок дагы эле ашыкча ток коргоосунун орнотулган болушу суралат. Сураныч, типтүү маалыматты караңыз. ampкеректелүүчү сактагычтын же өчүргүчтүн өлчөмүнө жараша төмөндөгү таблицада көрсөтүлөт.
ЭСКЕРТҮҮ! Бардык зымдарды квалификациялуу персонал аткарышы керек.
ЭСКЕРТҮҮ! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable as below.
Сунушталган батарея кабелинин өлчөмү:
| Модел | Зым өлчөмү | Кабель (мм²) | Моменттин мааниси (макс) |
|---|---|---|---|
| 3.6KW/6.2KW | 1 x 2AWG | 25 | 2 Нм |
Сураныч, батареяны туташтыруу үчүн төмөнкү кадамдарды аткарыңыз:
- Оң жана терс өткөргүчтөр үчүн 18 мм изоляциялык жеңди алып салыңыз.
- Туура кысуу куралы менен оң жана терс зымдардын учуна жүктөөчү феррулдарды коюуну сунуш кылыңыз.
- Connect all battery packs as shown in the diagram (refer to PDF page 7 for detailed diagram).
- Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with a torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the inverter/charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage сериясында.
АБАЙЛАҢЫЗ!! Акыркы DC туташуудан же DC өчүргүчтү/ажыраткычты жабуудан мурун, оң (+) оң (+) менен жана терс (-) терс (-) менен туташтырылышы керек.
3.6 AC Киргизүү/Чыгуу Туташуу
АБАЙЛАҢЫЗ!! AC кириш кубат булагына туташтыруудан мурун инвертор менен AC кириш кубат булагынын ортосунда өзүнчө AC өчүргүчтү орнотуңуз. Бул техникалык тейлөө учурунда инвертордун коопсуз ажыратылышын жана AC киришинин ашыкча токунан толук корголушун камсыздайт. AC өчүргүчтүн сунушталган спецификациясы 32 кВт үчүн 3.6А жана 50 кВт үчүн 6.2А болуп саналат.
АБАЙЛАҢЫЗ!! "IN" жана "OUT" белгилери бар эки терминалдык блок бар. Киргизүү жана чыгаруу туташтыргычтарын туура эмес туташтырбаңыз.
ЭСКЕРТҮҮ! Бардык зымдарды квалификациялуу персонал аткарышы керек.
ЭСКЕРТҮҮ! Системанын коопсуздугу жана натыйжалуу иштеши үчүн AC киргизүү туташуусу үчүн тиешелүү кабелди колдонуу абдан маанилүү. Жаракат алуу коркунучун азайтуу үчүн, төмөндө көрсөтүлгөндөй сунушталган кабелдин туура өлчөмүн колдонуңуз.
AC зымдары үчүн сунушталган кабелдик талаптар:
| Модел | ченегич | Кабель (мм²) | Моменттин мааниси |
|---|---|---|---|
| 3.6КВт | 12 AWG | 4 | 1.2 Нм |
| 6.2КВт | 10 AWG | 6 | 1.2 Нм |
AC киргизүү/чыгарма байланышын ишке ашыруу үчүн төмөнкү кадамдарды аткарыңыз:
- AC киргизүү/чыгарма туташтыруудан мурун, адегенде DC коргоочу же ажыраткычты ачууну унутпаңыз.
- Алты өткөргүч үчүн 10 мм изоляциялык жеңди алып салыңыз. Жана фаза L жана нейтралдуу өткөргүч N 3 мм кыскартат.
- Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. L→LINE (brown or black), N→Neutral (blue).
ЭСКЕРТҮҮ: Түзмөккө туташтыруудан мурун AC кубат булагы ажыратылганын текшериңиз.
- Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws. L→LINE (brown or black), N→Neutral (blue).
- Зымдар бекем туташтырылганын текшериңиз.
ЭСКЕРТҮҮ: Appliances such as air conditioner are required at least 2~3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check the manufacturer of the air conditioner if it's equipped with a time-delay function before installation. Otherwise, this inverter/charger will trigger an overload fault and cut off output to protect your appliance, but sometimes it still causes internal damage to the air conditioner.
3.7 PV туташуу
ЭСКЕРТҮҮ: PV модулдарына туташтыруудан мурун, инвертор менен PV модулдарынын ортосуна DC автоматтык өчүргүчтү өзүнчө орнотуңуз.
ЭСКЕРТҮҮ! Тутумдун коопсуздугу жана натыйжалуу иштеши үчүн фотоэлектрдик модулду туташтыруу үчүн тиешелүү кабелди колдонуу абдан маанилүү. Жаракат алуу коркунучун азайтуу үчүн, төмөндө көрсөтүлгөндөй сунушталган кабелдин туура өлчөмүн колдонуңуз.
Suggested cable requirement for PV wires:
| Модел | Зым өлчөмү | Кабель (мм²) | Моменттин мааниси (макс) |
|---|---|---|---|
| 3.6KW/6.2KW | 1 x 12AWG | 4 | 1.2 Нм |
PV модулун тандоо: Туура PV модулдарын тандоодо, төмөнкү параметрлерди эске алууну унутпаңыз:
- Open circuit VoltagPV модулдарынын e (Voc) максимумдан ашпайт. PV массив ачык чынжыр тtagинвертордун e.
- Open circuit VoltagPV модулдарынын e (Voc) минден жогору болушу керек. батарея томtage.
PV модулунун зым туташуу:
- Оң жана терс өткөргүчтөр үчүн 10 мм изоляциялык жеңди алып салыңыз.
- Туура кысуу куралы менен оң жана терс зымдардын учуна жүктөөчү феррулдарды коюуну сунуш кылыңыз.
- Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.
3.8 Жыйынтыктоочу Ассамблея
After connecting all wirings, please put the bottom cover back by screwing two screws.
3.9 Байланыш байланышы
1. Wi-Fi cloud communication (option): Please use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP and install it from the APP store, and refer to the “Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status would be shown by the mobile phone APP or webкомпьютердин барагы.

2. GPRS cloud communication (option): Please use the supplied communication cable to connect to the inverter and GPRS module, and then apply external power to the GPRS module. Download the APP and install it from the APP store, and refer to the "GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status would be shown by the mobile phone APP or webкомпьютердин барагы.
3. Battery communication: The communication between the battery and the inverter can be realized through the battery communication interface, so that the inverter and the lithium battery can exchange information.
4. Операция
4.1 Кубатты КҮЙГҮЗҮҮ/ӨЧҮРҮҮ
Агрегат туура орнотулгандан жана батарейкалар жакшы туташтырылгандан кийин, аппаратты күйгүзүү үчүн жөн гана күйгүзүү/өчүрүү баскычын (корпустун түбүндө жайгашкан) басыңыз.
4.2 Иштетүү жана дисплей панели
The operation and display panel, shown below, is on the front panel of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.

LED көрсөткүчү:
| LED көрсөткүч | Кабарлар |
|---|---|
| INV/AC (Green Solid On) | Чыгуу Line режиминде утилита менен иштейт. |
| INV/AC (Green Flashing) | Чыгуу батарея режиминде батарея же PV менен иштейт. |
| CHG (Green Solid On) | Батарея толук заряддалган. |
| CHG (Green Flashing) | Батарея заряддалууда. |
| FAULT (Red Solid On) | Инвертордо ката пайда болот. |
| FAULT (Red Flashing) | Эскертүү шарты инвертордо пайда болот. |
Функция баскычтары:
| Function Key | Description |
|---|---|
| ESC | Орнотуу режиминен чыгуу үчүн |
| UP | Мурунку тандоого өтүү үчүн |
| ылдый | Кийинки тандоого өтүү үчүн |
| ENTER | Жөндөө режиминде тандоону ырастоо же орнотуу режимине кирүү |
4.3 ЖК дисплейдин сөлөкөттөрү
The LCD display provides various icons to indicate the inverter's status and information. These include input source information (AC input, PV input, input voltage/frequency, PV voltagд, заряддоочу ток, батарея томtage), configuration program and fault information (setting programs, warning/fault codes), output information (output voltage/frequency, load percent, load in VA/Watt, discharging current), battery information, load information (overload), mode operation information (unit connected to mains/PV panel, load supplied by utility, utility charger circuit working, DC/AC inverter circuit working), and mute operation (alarm disabled).
4.4 ЖК орнотуу
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press “UP” or “DOWN” button to select setting programs. And then, press "ENTER" button to confirm the selection or ESC button to exit. Refer to PDF pages 14-20 for detailed LCD setting programs and options.
4.5 Дисплейди орнотуу
The LCD display information will be switched in turns by pressing the "UP" or "DOWN" key. The selectable information includes input voltage, киргизүү жыштыгы, PV томtagд, заряддоо агымы, заряддоо күчү, батарейканын көлөмүtage, чыгаруу көлөмүtagд, чыгаруу жыштыгы, жүк пайызыtage, load in Watt, load in VA, load in Watt, DC discharging current, and main CPU Version. Refer to PDF pages 21-26 for detailed display settings and examples.
4.6 Иштөө режиминин сүрөттөлүшү
The inverter supports various operating modes including Standby mode, Line mode, Grid-Tie Operation, and Battery mode. Each mode has specific conditions and display characteristics. Refer to PDF pages 25-26 for detailed descriptions of each operating mode.




4.7 Батареяны теңдөө сүрөттөлүшү
Equalization function is added into the charge controller. It reverses the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalization also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, will reduce the overall capacity of the battery. Therefore, it's recommended to equalize the battery periodically.
How to Apply Equalization Function: Адегенде LCD жөндөө программасынын 30 мониторингинде батареяны теңдөө функциясын иштетишиңиз керек. Андан кийин, сиз бул функцияны аппаратта төмөнкү ыкмалардын бири менен колдонсоңуз болот:
- 35-программада теңдөө аралыгын орнотуу.
- 36-программада дароо активдүү теңдөө.
When to Equalize: Калкыма сtagд, жөндөө теңдөө аралыгы (батареяны теңдөө цикли) келгенде же теңдөө дароо активдүү болгондо, контроллер Теңдөө s кире баштайт.tage.
Equalize charging time and timeout: In Equalize сtagд, контроллер батарейканы мүмкүн болушунча заряддоо үчүн кубат беретtage raises to the battery equalization voltagд. Андан кийин, туруктуу-томtagБатареянын көлөмүн сактоо үчүн электрондук жөнгө салуу колдонулатtagе батареяны теңдөө көлөмүtagд. Батарея Equalize с ичинде калатtage until the setting battery equalized time is arrived. However, if the battery equalized time is expired and the battery voltage doesn't rise to the battery equalization voltage point, the charge controller will extend the battery equalized time until the battery voltage achieves the battery equalization voltagд. Эгерде батареянын томtage дагы эле батарейканын теңдөө көлөмүнөн төмөнtage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.
5. Техникалык тейлөө
5.1 Overview of Anti-Dust Kit
Every inverter is already installed with an anti-dust kit from the factory. The inverter will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature. This kit also keeps dust from your inverter and increases product reliability in harsh environments.
5.2 Clearance and Maintenance of Anti-Dust Kit
1-кадам: Please loosen the screw in the counterclockwise direction on the top of the inverter.
2-кадам: Then, the dustproof case can be removed, and the air filter foam can be taken out (refer to PDF page 30 for diagrams).
3-кадам: Clean the air filter foam and dustproof case. After clearance, re-assemble the dust-kit back to the inverter.
ЭСКЕРТҮҮ: Чаңга каршы комплект ар бир ай сайын чаңдан тазаланууга тийиш.
6. Кыйынчылыктарды
6.1 Ката маалымдама коду
The inverter provides fault codes to help diagnose issues. Refer to the table below for common fault codes and their explanations.
| Ката коду | Ката окуясы | Түшүндүрмө / Мүмкүн болгон себеп | Эмне кылуу керек |
|---|---|---|---|
| 01 | Инвертор өчүк болгондо желдеткич кулпуланган. | Күйөрмандын катасы | Желдеткичти алмаштырыңыз. |
| 02 | Ашыкча температура | Инвертор компонентинин ички температурасы 100°Сден жогору. | Агрегаттын аба агымы бөгөлүп калганын же чөйрөнүн температурасы өтө жогору экендигин текшериңиз. |
| 03 | Батарея көлөмүtage өтө жогору | Батарея ашыкча заряддалган. | Батареялардын спецификациясы жана саны талаптарга жооп берерин текшериңиз. |
| 04 | Батарея көлөмүtage өтө төмөн | батарея томtage өтө төмөн. (<1.4V/Cell) | Батареяны кайра заряддаңыз. Батареяны алмаштырыңыз. |
| 05 | Чыгуу кыска туташуусу же ашыкча температура ички конвертер компоненттери тарабынан аныкталат. | Чыгуу кыска туташуусу. | Зымдар жакшы туташтырылганын текшерип, анормалдуу жүктү алып салыңыз. |
| 06/58 | Чыгуу томtage is too high / Output abnormal | Чыгуу анормалдуу (Инвертор тtage 190Vac төмөн же 260Vac жогору) | Reduce the connected load. Return to repair center. |
| 07 | Ашыкча жүктөө убактысы бүттү | Ашыкча жүктөө катасы. Инвертор ашыкча жүктөө 110% жана убакыт бүттү. | Кээ бир жабдууларды өчүрүү менен туташкан жүктү азайтыңыз. |
| 08/09/53/57 | Автобус томtage is too high / Bus soft start failed / Inverter soft start failed / Current sensor failed | Ички компоненттери ишке ашкан жок. | Оңдоо борборуна кайтуу. |
| 51 | Ашыкча ток же толкун. | Ашыкча ток же толкун. | Түзмөктү кайра иштетиңиз, эгер ката кайталанса, оңдоо борборуна кайрылыңыз. |
| 52 | Автобус томtage өтө төмөн. | Автобус томtage өтө төмөн. | Түзмөктү кайра иштетиңиз, эгер ката кайталанса, оңдоо борборуна кайрылыңыз. |
| 55 | Чыгуу томtage тең салмактуу эмес. | Чыгуу томtage тең салмактуу эмес. | Түзмөктү кайра иштетиңиз, эгер ката кайталанса, оңдоо борборуна кайрылыңыз. |
6.2 Эскертүү индикатору
The inverter provides warning indicators for various conditions. Refer to the table below for common warning codes and their audible alarms.
| Эскертүү коду | Эскертүү окуясы | Үндүү сигнал |
|---|---|---|
| 01 | Инвертор күйгүзүлгөндө желдеткич кулпуланган. | Секунда сайын үч жолу сигнал |
| 03 | Батарея ашыкча заряддалган | секунд сайын бир жолу сигнал |
| 04 | Батарея аз | секунд сайын бир жолу сигнал |
| 07 | Ашыкча жүктөө | 0.5 секундада бир жолу сигнал |
| 10 | Чыгуу күчүн азайтуу | Ар бир 3 секундда эки жолу бип |
| 15 | PV энергиясы аз. | Ар бир 3 секундда эки жолу бип |
| E9 | Батареяны теңдөө | Жок |
| bP | Батарея туташкан эмес | Жок |
7. Техникалык шарттар
7.1 Line Mode Specifications
| ИНВЕРТОР МОДЕЛИ | 3.6КВт | 6.2КВт |
|---|---|---|
| Киргизүү көлөмүtage Waveform | Синусоидалдык (пайдалуу же генератор) | |
| Номиналдык киргизүү Voltage | 100Vac | |
| Low Loss Voltage | 90Vac±5V (UPS); 90Vac±5V (тиричилик) | |
| Low Loss Return Voltage | 95Vac±5V (UPS); 95Vac±5V (тиричилик) | |
| High Loss Voltage | 145Vac±5V | |
| High Loss Return Voltage | 140Vac±5V | |
| Макс AC Киргизүү Voltage | 150Vac | |
| Номиналдык киргизүү жыштыгы | 50Гц / 60Гц (Автоматтык аныктоо) | |
| Төмөн жоготуу жыштыгы | 40±1Гц | |
| Төмөн жоготууларды кайтаруу жыштыгы | 42±1Гц | |
| Жогорку жоготуу жыштыгы | 65±1Гц | |
| Жогорку жоготууларды кайтаруу жыштыгы | 63±1Гц | |
| Чыгуу кыска туташуусу коргоо | Circuit Breaker | |
| Натыйжалуулук (сызык режими) | >95% (R номиналындагы жүктөмү, батарейка толук заряддалган) | |
| Которуу убактысы | 10 мс типтүү (UPS); 20ms типтүү (тиричилик) | |
7.2 Inverter Mode Specifications
| ИНВЕРТОР МОДЕЛИ | 3.6КВт | 6.2КВт |
|---|---|---|
| Чыгуучу кубаттуулук | 3.6КВт | 6.2КВт |
| Output Voltage Waveform | Таза синус толкуну | |
| Output Voltage Регламент | 100/105/110/115/120Vac±5% | |
| Чыгуу жыштыгы | 50Гц / 60Гц | |
| Эффективдүүлүктүн эң жогорку деңгээли | 93% | |
| Ашыкча жүктөн коргоо | 3s@≥150%; 5s@101%~150% load | |
| Толук кубаттуулук | 2 * номиналдык кубаттуулугу 5 секунд | |
| Номиналдуу DC Input Voltage | 24Vdc | 48Vdc |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc |
| Төмөн DC Warning Voltage @load < 50% | 22.0Vdc | 44.0Vdc |
| Төмөн DC Warning Voltage @load ≥ 50% | 21.0Vdc | 42.0Vdc |
| Low DC Warning Return Voltage @load < 50% | 22.5Vdc | 45.0Vdc |
| Low DC Warning Return Voltage @load ≥ 50% | 22.0Vdc | 44.0Vdc |
| Low DC Cut-off Voltage @load < 50% | 20.5Vdc | 41.0Vdc |
| Low DC Cut-off Voltage @load ≥ 50% | 20.0Vdc | 40.0Vdc |
| High DC Recovery Voltage | 32Vdc | 62Vdc |
| High DC Cut-off Voltage | 33Vdc | 63Vdc |
| Эч кандай жүк кубат керектөө | 45 Вт | 50 Вт |
7.3 Two Load Output Power
| ИНВЕРТОР МОДЕЛИ | 3.6КВт | 6.2КВт |
|---|---|---|
| Толук жүк | 3600 Вт | 6200 Вт |
| Максималдуу негизги жүк | 3600 Вт | 6200 Вт |
| Максималдуу экинчи жүк (батарея модели) | 1200 Вт | 2066 Вт |
| Main Load Cut Off Voltage | 26VDC | 52VDC |
| Main Load Return Voltage | 27VDC | 54VDC |
7.4 Charge Mode Specifications
| ИНВЕРТОР МОДЕЛИ | 3.6КВт | 6.2КВт |
|---|---|---|
| Заряддоо алгоритми | 3-кадам | |
| AC заряддоо агымы (макс.) | 80Amp (@VI/P=100 Vac) | |
| Жаппай заряддоо Voltage (Суу баскан батарея) | 29.2 | 58.4 |
| Жаппай заряддоо Voltage (AGM / Gel Battery) | 28.2 | 56.4 |
| Floating Charging Voltage | 27Vdc | 54Vdc |
| Макс. PV Array күчү | 4200 Вт | 6500 Вт |
| Номиналдуу PV Voltage | 240Vdc | 360Vdc |
| PV Array MPPT Voltage Диапазон | 60Vdc~500Vdc | |
| Макс. PV Array Open Circuit Voltage | 500Vdc | |
| Максималдуу кубаттоо тогу (өзгөрмө ток кубаттагыч жана күн кубаттагыч) | 120Amp | 120Amp |
7.5 Grid-Tie Operation
| ИНВЕРТОР МОДЕЛИ | 3.6КВт | 6.2КВт |
|---|---|---|
| Номиналдуу Чыгуу Voltage | 100/105/110/115/120VAC | |
| Feed-in Grid Voltage Диапазон | 90~150VAC | |
| Feed-In Grid жыштык диапазону | 49~51±1Hz/59~61±1Hz | |
| Номиналдык чыгуу агымы | 30A | 51.7A |
| Power Factor диапазону | >0.99 | |
| Конверсиянын максималдуу эффективдүүлүгү (DC/AC) | 97% | |
7.6 Жалпы спецификациялар
| ИНВЕРТОР МОДЕЛИ | 3.6КВт | 6.2КВт |
|---|---|---|
| Коопсуздук сертификаты | CE | |
| Иштөө температурасы диапазону | -10°Cден 50°Cге чейин | |
| Сактоо температурасы | -15°C~60°C | |
| Нымдуулук | 5%дан 95%га чейин Салыштырмалуу нымдуулук (конденсацияланбаган) | |
| Өлчөмү (D*W*H), мм | 110X334X423 | 110X334X423 |
| Таза Салмагы, кг | 9 | 10 |
7.7 Approximate Back-up Time Table
The following tables provide approximate back-up times for different loads and battery configurations.
| Модел | Жүк (W) | Камдык сактоо убактысы @ 24Vdc 100Ah (мин) | Камдык сактоо убактысы @ 24Vdc 200Ah (мин) |
|---|---|---|---|
| 3.6КВт | 300 | 449 | 1100 |
| 600 | 222 | 525 | |
| 900 | 124 | 303 | |
| 1200 | 95 | 227 | |
| 1500 | 68 | 164 | |
| 1800 | 56 | 126 | |
| 2100 | 48 | 108 | |
| 2400 | 35 | 94 | |
| 2700 | 31 | 74 | |
| 3200 | 28 | 67 | |
| 3600 | 25 | 60 | |
| 4200 | 22 | 53 | |
| 6.2КВт | 500 | 613 | 1288 |
| 1000 | 268 | 613 | |
| 1500 | 158 | 402 | |
| 2000 | 111 | 271 | |
| 2500 | 90 | 215 | |
| 3200 | 76 | 182 | |
| 3500 | 65 | 141 | |
| 4000 | 50 | 112 | |
| 4500 | 44 | 100 | |
| 5000 | 40 | 90 | |
| 6200 | 36 | 80 |
Эскертүү:
- Камдык сактоо убактысы батареянын сапатына, батареянын жашына жана батареянын түрүнө жараша болот. Батареялардын мүнөздөмөлөрү ар кандай өндүрүүчүлөргө жараша ар кандай болушу мүмкүн.
- Бул буюмдун акыркы чечмелөө укугу компанияга таандык.


8. Колдонуучунун кеңештери
- Туура өлчөм: Ensure your solar panel array and battery bank are appropriately sized for your energy needs and the inverter's specifications to maximize efficiency and lifespan.
- Вентиляция: Always ensure adequate clearance around the inverter for proper air circulation to prevent overheating, especially in warmer climates.
- үзгүлтүксүз тазалоо: Clean the anti-dust kit monthly to maintain optimal performance and prevent dust buildup from affecting internal components.
- Монитор аткаруу: Utilize the optional WiFi module and mobile app to monitor the inverter's status, charging, and output in real-time for proactive management.
- Батареянын ден соолугу: Pay attention to battery equalization settings and ensure your batteries are regularly equalized if they are of a type that benefits from it, to prolong battery life.
- Салмагы жана өлчөмдөрү: The inverter weighs approximately 9.5 kg (20.9 lbs) with package dimensions of 48 cm (L) x 37 cm (W) x 16 cm (H). Consider these when planning installation and handling.
9. Кепилдик жана колдоо
For detailed warranty information, service, and technical support, please refer to the complete user manual PDF available at: Hybrid Inverter User Manual (PDF). If you encounter any issues not covered in this manual or require further assistance, please contact your local dealer or the manufacturer's customer service.