1. Киришүү
The KAIWEETS HT208D is a professional True-RMS AC/DC clamp meter designed for accurate and reliable electrical measurements. It features a wide range of functions including AC/DC current up to 1000A, AC/DC voltage up to 1000V, resistance, capacitance, frequency, duty cycle, temperature, diode, and continuity. This meter is equipped with advanced features such as Inrush current measurement for identifying startup issues, VFD (Variable Frequency Drive) filtering, and LoZ (Low Input Impedance) mode for enhanced accuracy. Its robust design and safety compliance make it suitable for use in laboratories, factories, and households.
2. Коопсуздук маалыматы
Please read and understand all safety information and operating instructions before using this instrument. Failure to follow safety warnings and instructions may result in electric shock, fire, or serious injury.
- This device meets safety standards IEC 61010-1, CAT IV 600V, and CAT III 1000V.
- Features double insulation and high-quality materials to prevent electric shock hazards.
- Always inspect the meter, test leads, and accessories for any damage before use. Do not use if damaged.
- Баалангандан ашык колдонбоңузtage, эсептегичте белгиленгендей, терминалдардын ортосунда же каалаган терминал менен жердин ортосунда.
- Том менен иштөөдө этият болуңузtag30V AC RMS, 42V пик же 60V DC жогору. Бул томtagшок коркунучун жаратат.
- Эсептегичти жарылуучу газ, буу же чаңдуу чөйрөдө иштетпеңиз.
- Ensure the rotary switch is in the correct position for the desired measurement before connecting to the circuit.
- cl менен токту өлчөгөндөamp, ensure the circuit is de-energized before clamping around the conductor, if possible.
- Батарея аз индикатор пайда болгондо, батарейкаларды дароо алмаштырыңыз.

3. Продукт бүтүп калдыview
3.1 Негизги өзгөчөлүктөрү
- True-RMS measurement for accurate readings on non-sinusoidal waveforms.
- Measures AC/DC Current up to 1000A.
- Чаралар AC/DC Voltage 1000V чейин.
- Inrush Current function to capture motor startup current.
- VFD (Variable Frequency Drive) mode for accurate measurements on variable frequency signals.
- LoZ (Low Input Impedance) mode to eliminate ghost voltages.
- Measures Resistance, Capacitance, Frequency, Duty Cycle, Diode, and Continuity.
- Temperature measurement with K-type thermocouple.
- Байланышсыз томtage (NCV) аныктоо.
- Built-in LED flashlight for illuminating dark work areas.
- 6000 Counts display with backlight.
- Data Hold, MAX/MIN, REL (Relative Measurement), and ZERO functions.
- Auto-ranging with manual range selection (RAN button).
3.2 Пакеттин мазмуну
Пакет төмөнкү нерселерди камтыйт:
- 1 x KAIWEETS HT208D Digital Clamp Метр
- 2 x Сыноочу (Кызыл жана Кара)
- 1 x K-түрү термопар
- 3 x AAA Batteries (Assembly Required)
- 1 x User Manual
- 1 x Clamp Meter Bag
- 1 x Packing Box

3.3 метрлик жайгашуу



4. Орнотуу
4.1 Батареяны орнотуу
The KAIWEETS HT208D requires 3 AAA batteries for operation. To install or replace batteries:
- Эсептегич өчүрүлгөнүн текшериңиз.
- Батарея бөлүмүнүн капкагын эсептегичтин арткы бетинен табыңыз (2.1-сүрөттү караңыз).
- Батареянын капкагын бекиткен бурагычты(ларды) бошотуш үчүн бурагычты колдонуңуз.
- Remove the cover and insert 3 AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
- Батареянын капкагын кайра ордуна коюп, бурамаларыңызды бекемдеңиз.
4.2 Connecting Test Leads and Thermocouple
Том үчүнtage, resistance, capacitance, diode, continuity, and temperature measurements, connect the test leads or thermocouple to the input jacks:
- Кызыл сыноо өткөргүчтү "VΩHz" уячасына салыңыз.
- Кара тест өткөргүчтү "COM" уячасына салыңыз.
- For temperature measurements, connect the K-type thermocouple to the "VΩHz" (positive) and "COM" (negative) jacks, ensuring correct polarity.
5. Иштөө нускамалары
Turn the rotary switch to the desired function. Use the "FUNC" button to cycle through sub-functions if available (e.g., AC/DC voltagд, диод/үзгүлтүксүздүк).
5.1 AC/DC Voltage Өлчөө
- Turn the rotary switch to the "V" position.
- Press the "FUNC" button to select between AC (~) or DC (---) voltage.
- Сыноо өткөргүчтөрүн текшерилип жаткан схемага же компонентке параллелдүү туташтырыңыз.
- Томду окуңузtage мааниси дисплейде.

5.2 AC/DC Ток өлчөө (Clamp)
- Turn the rotary switch to the "A" position (AC or DC current).
- Press the "FUNC" button to select between AC (~) or DC (---) current.
- cl ачыңызamp jaw and enclose only one conductor of the circuit. Ensure the jaw is fully closed.
- Дисплейдеги учурдагы маанини окуңуз.

5.3 Кирип келүүчү токту өлчөө
The Inrush function helps identify startup issues in motors or circuits by capturing the peak current during startup. This function is only available in AC mode.
- Turn the rotary switch to the "A~" (AC Current) position.
- Press the "INRUSH" button. The display will show "INRUSH".
- cl ачыңызamp jaw and enclose only one AC conductor of the circuit.
- Activate the device or motor to be tested. The meter will capture the inrush current over approximately 100ms.
- Read the inrush current value on the display.

5.4 Каршылык, сыйымдуулук, диод жана үзгүлтүксүздүктү өлчөө
- Айлануучу которгучту "Ω" абалына буруңуз.
- Press the "FUNC" button to cycle through Resistance (Ω), Diode (▶|), or Continuity ())) modes.
- Connect the test leads to the component under test.
- Read the measurement on the display. For continuity, a beep indicates a continuous circuit.

5.5 Жыштык жана кызматтык циклди өлчөө
- Turn the rotary switch to the "Hz%" position.
- Press the "FUNC" button to select between Frequency (Hz) or Duty Cycle (%).
- Сыноо өткөргүчтөрүн сигнал булагына туташтырыңыз.
- Дисплейдеги өлчөөнү окуңуз.
5.6 Температураны өлчөө
- Turn the rotary switch to the "TEMP" position.
- Connect the K-type thermocouple to the "VΩHz" (positive) and "COM" (negative) jacks.
- Термопаранын учун температурасы өлчөнүүчү объекттин үстүнө же жанына коюңуз.
- Read the temperature on the display. Press "FUNC" to switch between Celsius (°C) and Fahrenheit (°F).
5.7 Контактсыз томtage (NCV) аныктоо
- Turn the rotary switch to the "NCV/LIVE" position.
- Move the top of the meter near a conductor or outlet.
- The meter will beep and the LED indicator will flash if AC voltagе аныкталат.

5.8 VFD and LoZ Modes
- VFD (Variable Frequency Drive): Select the AC Voltage or AC Current function, then press the "VFD" button to activate VFD mode. This mode filters out high-frequency noise and measures the fundamental frequency of variable frequency drives.
- LoZ (Low Input Impedance): Select the AC Voltage function, then press the "LOZ" button to activate LoZ mode. This mode provides a low impedance input to drain ghost voltages, giving more accurate readings in certain applications.
5.9 Баскыч функциялары
- FUNC: Cycles through sub-functions (e.g., AC/DC, Diode/Continuity).
- RAN: Switches between auto-ranging and manual ranging. Press and hold for 2 seconds to return to auto-ranging.
- МАКС/МИН: Displays the maximum or minimum measured value.
- REL/ZERO: Relative measurement mode or zeroing the display for capacitance/resistance.
- INRUSH: Activates Inrush current measurement (AC mode only).
- КАРУУ/ЖАРЫК: Short press to hold the current reading. Long press to turn the backlight on/off.
- VFD: Activates Variable Frequency Drive mode.
- спокоен: Activates Low Input Impedance mode.
6. Техникалык тейлөө
6.1 Тазалоо
Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Keep the input terminals free of dirt and moisture.
6.2 Батареяны алмаштыруу
When the low battery indicator appears on the display, replace the batteries as described in Section 4.1. Remove batteries if the meter is not used for an extended period.
6.3 Сактоо
Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided clamp meter bag for protection.
7. Кыйынчылыктарды
If the meter does not function correctly, check the following:
- Дисплей жок же күңүрт дисплей: Check battery level and replace if necessary.
- Туура эмес окуулар:
- Ensure the test leads are correctly inserted and not damaged.
- Айланма которгуч туура функцияга жана диапазонго коюлганын текшериңиз.
- For current measurements, ensure only one conductor is within the clamp жаак.
- Тышкы тоскоолдуктарды же күчтүү магниттик талааларды текшериңиз.
- Эсептегич жооп бербей жатат: Turn the meter off and then on again. If the issue persists, remove and reinsert the batteries.
8. Техникалык шарттар
Detailed specifications for the KAIWEETS HT208D Clamp Meter are provided below:

| Категория | Параметр |
|---|---|
| Генерал | Бренд: KAIWEETS Type: Inrush Clamp Метр Model: HT208D Color: Black + Red |
| Спецификация | DC Voltage: 600mV/6V/60V/600V/1000V, ±(0.5%+3) AC Voltage: 600mV/6V/60V/600V/750V, ±(0.8%+3) DC Current: 60A/600A/1000A, ±(2.5%+5) AC Current: 60A/600A/1000A, ±(2.5%+5) Resistance: 600Ω/6KΩ/60KΩ/600KΩ/6MΩ/60MΩ, ±(0.8%+3) Capacitance: 10nF/100nF/1uF/10uF/100uF/1mF/10mF/100mF, ±(3.0%+3) Frequency: 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz, ±(0.5%+5) Duty: 1%~99%, ±(1.0%+2) Temperature: -40°C-1000°C ±(1.0%+2), -40℉-1832℉ ±(1.0%+2) Саны: 6000 |
| Салмагы жана өлчөмү | Продукт Салмагы: 0.7 кг Пакет Салмагы: 0.7kg Package Size(L x W x H): 28.5x13.5x6cm |
9. Колдонуучунун кеңештери
- Remember that the Inrush current function is specifically designed for AC circuits and will not operate in DC mode.
- For accurate temperature readings, ensure the K-type thermocouple is properly connected and in good contact with the surface being measured.
- cl колдонгондоamp for current measurements, always isolate the single conductor you wish to measure. Clamping around multiple conductors (e.g., a power cord with live and neutral) will result in a zero or incorrect reading.
10. Кепилдик жана колдоо
Кепилдик маалыматы, техникалык колдоо же тейлөө боюнча суроо үчүн, сатуучуга же өндүрүүчүгө түздөн-түз кайрылыңыз. Сатып алганыңыздын далили катары сатып алуу дүмүрчөгүңүздү сактаңыз.