1. Киришүү
The Elitech MS-4000 is an advanced 4-way digital manifold gauge designed for HVAC professionals. It integrates multiple HVAC tools into a single unit, providing precise measurements for pressure, temperature, and vacuum. This device features a smart touch screen, real-time monitoring via an app, OTA firmware updates, intelligent vacuum leakage judgment, offline data recording, and temperature compensation for accurate tightness testing. It supports 88 different refrigerants and offers automatic calculation of superheating and subcooling temperatures.

Figure 1: Elitech MS-4000 Digital Manifold Gauge with accessories in carrying case.
2. Орнотуу
2.1 Кутудан чыгаруу жана компоненттерди идентификациялоо
Carefully unpack the Elitech MS-4000 from its packaging. Verify that all components are present and undamaged. The standard package includes the MS-4000 manifold unit, charging hoses (red, blue, yellow), temperature clamps, and a performance report.
Video 1: Unboxing the Elitech MS-4000 Digital Manifold Gauge and its components.
2.2 Battery Installation and Power On
The MS-4000 is powered by a Type-C charging port and has a battery capacity of 20 hours. For initial use or after long storage, ensure the device is charged. If using AA batteries (for models like MS-1000, though MS-4000 uses Type-C charging), install 3 AA batteries into the designated compartment. To power on, press and hold the power button until the screen illuminates.

Figure 2: Display showing battery removal for storage (relevant for some models).
2.3 Колдонмону орнотуу жана туташуу
Download the Elitech Tools App from your device's app store (iOS and Android compatible). Follow the in-app instructions to connect your MS-4000 manifold gauge via Bluetooth for real-time monitoring, OTA firmware updates, and data management.

Figure 3: Real-time monitoring and OTA firmware updates via the Elitech Tools App.
3. Иштөө нускамалары
3.1 General Operation and Touch Screen Interface
The MS-4000 features a 5-inch touch screen for intuitive navigation. The interface displays vacuum, pressure, and temperature data clearly. Use the touch screen to select functions and adjust settings.

Figure 4: Key features of the Elitech MS-4000, including the 5-inch touch screen.
3.2 Басым жана температура өлчөө
Connect the appropriate hoses to the 4-way valve and the HVAC system. The device will display pressure and temperature readings in real-time. The MS-4000 automatically measures superheating and subcooling temperatures for 88 different refrigerants. Frequently used refrigerants can be saved for quick access.
3.3 Вакуумдук өлчөө
The MS-4000 includes a micron gauge transmitter for precise vacuum measurements. Connect the vacuum pump and monitor the vacuum levels directly on the screen. The range for vacuum measurement is 0-19000 micron.
3.4 System Leakage Testing with Temperature Compensation
The device allows for precise monitoring of pressure holding and vacuum leakage tests. It features temperature compensation settings to minimize the influence of temperature variations on the accuracy of tightness testing results. Adjust allowable percentage and duration settings as needed.

Figure 5: Temperature compensation settings for accurate tightness testing.
3.5 Маалыматтарды жаздыруу жана экспорттоо
The MS-4000 can record up to 100,000 points of offline data. This data can be easily exported to a computer via a USB port for further analysis of temperature, pressure, and vacuum values.
3.6 Auto Off Time Settings
The device has an adjustable auto-off feature to conserve battery life. Default auto-off is set to 15 minutes, but options like 5, 10, 15, 30, and 60 minutes are selectable.
4. Техникалык тейлөө
4.1 Жалпы кам көрүү
Keep the manifold gauge clean and free from dust and debris. Store it in its protective carrying case when not in use to prevent damage. Avoid exposing the device to extreme temperatures or moisture.
4.2 Батареяны башкаруу
For long-term storage, it is recommended to fully charge the device and then store it in a cool, dry place. If the device uses removable batteries (like 3 AA batteries in some models), remove them if the unit will not be used for an extended period to prevent leakage.
5. Кыйынчылыктарды
5.1 Түзмөк күйбөй жатат
- Ensure the device is fully charged via the Type-C port.
- If applicable, check that batteries are correctly installed and not depleted.
5.2 Колдонмонун туташуу көйгөйлөрү
- Мобилдик түзмөгүңүздө Bluetooth иштетилгенин текшериңиз.
- Verify the Elitech Tools App is updated to the latest version.
- Restart both the manifold gauge and your mobile device.
- Ensure the manifold gauge is within Bluetooth range of your mobile device.
5.3 Туура эмес окуулар
- Бардык шланг байланыштарын агып кеткендигин текшериңиз.
- Температуранын жылышын камсыз кылыңызamps are securely attached to the pipes.
- Verify the correct refrigerant type is selected in the device settings.
- Perform a calibration check if available in the device menu or app.
6. Техникалык шарттар
6.1 Жалпы спецификациялар
| пункт | Нарк |
|---|---|
| Бренд аты | Элитех |
| Модель номери | MS-4000 |
| Продукт аты | Санариптик басым өлчөгүч |
| Колдонмо | Hydraulic Industries, Air Conditioning Fitting |
| Байланыш | 1/4" SAE*3 and 3/8" SAET*1 |
| Муздаткыч | R134A, R410A, R22A, R404A (and 84 other refrigerants) |
| Түс | Кызгылт сары/Кара |
| Connection Material | Brass Thread |
| Type | Gas Pressure Manometer |
| Салмагы | 7KG (Product package weight is 30kg) |
| Электр камсыздоо | Type-C заряддоо |
| Батарея сыйымдуулугу | 20 саат |
| Жаздыруу мүмкүнчүлүгү | 100,000 упай |
| Клапандар | 4 |
| басым диапазону | -14.5 ~ 800 psi |
| Тактык | 0.5% FS |
| Резолюция | 0.5 psi |
| Порт | 4 |
| Сенсордук экран | Ооба |
6.2 Температура Клamp Параметрлер
| пункт | Нарк |
|---|---|
| Диапазон | -40~150℃ / -40~300℉ |
| Тактык | ±0.1℃ / ±0.18℉ |
| Резолюция | 0.1℃ / ℉ |
6.3 Vacuum Parameters
| пункт | Нарк |
|---|---|
| Диапазон | 0-19000 микрон |
| Accuracy (0-10000 micron) | 10% of Reading ± 10 micron |
| Accuracy (10000-19000 micron) | Окуунун 20% |
6.4 Supported Refrigerants
R113, R114, R115, R116, R12, R123, R1233ZD, R1234ZE, R1234YF, R124, R125, R13, R134a, R14, R141B, R142B, R143A, R152A, R170, R22, R23, R236FA, R245FA, R290, R32, R401A, R401B, R401C, R402A, R402B, R403B, R404A, R406A, R407A, R407B, R407C, R407D, R407F, R408A, R409A, R410A, R410B, R412A, R413A, R414A, R414B, R416A, R417A, R417C, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R424A, R426A, R427A, R428A, R429A, R434A, R437A, R438A, R441A, R443A, R448A, R449A, R450A, R452A, R452B, R453A, R454A, R454B, R455A, R458A, R500, R502, R503, R507A, R508A, R508B, R514A, R600, R600a, R601a, R718, R744.
7. Колдонуучунун кеңештери
- Utilize the Elitech Tools App for enhanced functionality, including remote monitoring and data analysis, to streamline your workflow.
- Алдын алаtage of the temperature compensation feature during leakage tests to ensure the most accurate results, especially in environments with fluctuating temperatures.
- Regularly export recorded data via USB to keep a comprehensive log of your work and for detailed analysis.
- Customize the auto-off time setting to balance battery life and convenience based on your typical usage patterns.
- Keep the 4-way valve and hoses clean and properly sealed to prevent refrigerant cross-contamination and ensure accurate readings.
8. Кепилдик жана колдоо
8.1 Продукциянын кепилдиги
The Elitech MS-4000 Smart HVAC Digital Manifold Gauge comes with a 3-year warranty. This warranty covers manufacturing defects and ensures free spare parts for covered issues. Please retain your proof of purchase for warranty claims.
8.2 Техникалык колдоо
For technical assistance, troubleshooting, or service inquiries, please contact Elitech customer support. Refer to the official Elitech webакыркы байланыш маалыматы үчүн сайт же продукт таңгак.