1. Киришүү
The LILYTECH ZL-7918C is an intelligent temperature and humidity controller designed for incubators and similar applications. It offers precise control over various parameters essential for successful incubation, including temperature, humidity, egg turning, ventilation, and lighting. This manual provides detailed instructions for the installation, operation, and maintenance of your ZL-7918C controller.

2. Техникалык шарттар
The following table outlines the key technical specifications of the ZL-7918C controller:
| Өзгөчөлүк | Description |
|---|---|
| Электр камсыздоо | 100 ~ 240Vac, 50/60Hz |
| Киргизүүлөр | 1x Temperature Sensor (L=2.0m), 1x Humidity Sensor (L=2.0m), 1x Door Switch |
| Температураны орнотуу диапазону | 1 ~ 75°C (Fahrenheit and Celsius units) |
| Нымдуулукту орнотуу диапазону | 10 ~ 99% RH |
| Температураны көрсөтүү диапазону | -9.9 ~ 99.9°C |
| Нымдуулукту көрсөтүү диапазону | 0 ~ 99% RH |
| Температураны өлчөөнүн тактыгы | ±1% |
| Humidity Measuring Accuracy | ±3% |
| Чыгуулар | 8 outputs: Main-Heater, Aux-Heater, Lamp, Humidity, Ventilation Fan, Right-Turning, Left-Turning, Exhaustion Fan |
| Output Load (Max) | Main-Heater ≤ 1500W, Aux-Heater ≤ 1500W, Lamp ≤ 100W, Others ≤ 1A/250Vac |
| Hatched Day Counter | Макс 99 күн |
| Egg Turn Control Period | 1 ~ 999 мүнөт |
| Egg Turn Driving Time | 0 ~ 999 секунд |
| Egg Turn Times Counter | 0 ~ 999 жолу |
| Air Exhaustion Control Period | 1 ~ 999 мүнөт |
| Air Exhausting Time | 0 ~ 999 секунд |
| Lamp Контролдоо мезгили | 1 ~ 999 мүнөт |
| Жарыктандыруучу убакыт | 1 ~ 999 секунд |
| Иштөө чөйрөсү | -10 ~ 45°C, <90% RH (non-condensing) |
| Device Dimensions (L*W*H) | 160 * 80 * 95 мм |
| Installation Drilling Size | 151.5 * 76.5 мм |
| Type | Large-Sized Incubator Controller |
| Egg Turning Mode | Automatic Egg Turning |
| Колдонуу | Bird, Chicken, Duck, Goose, Ostrich, Reptile, Turkey, Emu incubation |
| Hatching Rate | Up to 90% (dependent on external factors) |
| Тtage | 110-240Vac |
| Салмагы | 0.7 кг |
| Негизги сатуу пункттары | Жогорку тактык |
| Колдонулуучу тармактар | Чарбалар |
3. Орнотуу жана орнотуу
3.1 Физикалык орнотуу
The ZL-7918C controller is designed for panel mounting. Ensure you have a cutout with dimensions of 151.5 мм x 76.5 мм for proper fit. Secure the controller using the provided mounting clips or screws.
3.2 Электр өткөргүч схемасы
Carefully follow the wiring diagram below to connect the power supply, sensors, and output devices (heaters, fans, egg turn motors, lamp, humidifier). Incorrect wiring can damage the unit or connected equipment. Always ensure power is disconnected before performing any wiring.

Зымдарды туташтыруу аяктадыview:
- 1-4-терминалдар: Sensor connections. Red, Yellow, Black, Orange wires for Temperature and Humidity sensors.
- 5-8-терминалдар: Switch input (S1).
- 9-12-терминалдар: Not explicitly labeled in diagram, typically for auxiliary functions or unused.
- 13-14-терминалдар: AC-N (Neutral) and AC-L (Live) for 100-240Vac power supply.
- 15-16-терминалдар: HEAT1 (Main Heater, max 1500W).
- 17-18-терминалдар: HEAT2 (Auxiliary Heater, max 1500W).
- 19-20-терминалдар: HUMI (Humidifier, max 7.5A).
- 21-22-терминалдар: LAMP (Lamp, max 300W).
- 23-24-терминалдар: CIR. FAN (Circulation Fan, max 7.5A).
- 25-26-терминалдар: EXHAUST (Exhaust Fan, max 5A).
- 27-28-терминалдар: RIGHT (Right Egg Turning Motor, max 1.5A).
- 29-30-терминалдар: LEFT (Left Egg Turning Motor, max 1.5A).
- PE: Protective Earth connection.
Ensure all connections are secure and insulated. Verify correct voltage and current ratings for all connected devices to prevent damage.
4. Иштөө нускамалары
4.1 Дисплейview

- PV (Process Value) TEMP: Displays the current measured temperature.
- PV (Process Value) WET%: Displays the current measured humidity.
- SV (Set Value) TEMP: Белгиленген температураны көрсөтөт.
- SV (Set Value) WET%: Displays the set humidity.
- Көрсөткүчтөр: FAN, HEAT1, HEAT2, UP, LAMP, DOWN, WET, ALARM indicate active functions or states.
- Баскычтар: SET, UP arrow, DOWN arrow, ENTER.
4.2 Негизги операция
- Күйгүзүү: After correct wiring, apply power to the controller. The display will light up, showing current temperature and humidity.
- Setting Temperature/Humidity:
- басыңыз SET button once to enter temperature setting mode. The SV TEMP value will flash.
- колдонуу UP жана ылдый каалаган температураны тууралоо үчүн жебе баскычтары.
- Басыңыз ENTER to confirm and save the setting, or SET again to cycle to humidity setting.
- Repeat for humidity setting (SV WET%).
- Басыңыз ENTER to save and exit setting mode.
- Egg Turning Control: The controller automatically manages egg turning based on programmed period and driving time. These parameters can be adjusted in the advanced settings menu (refer to the full manual for detailed menu navigation).
- Ventilation and Exhaustion: The ventilation fan and exhaustion fan operate based on programmed periods and times to ensure proper air exchange. These settings are also configurable in the advanced menu.
- Lamp Контролдоо: лamp can be set to illuminate for specific periods and durations, useful for observation.
- Hatched Day Counter: The controller tracks the number of days since incubation started, up to 99 days.
4.3 Өркүндөтүлгөн жөндөөлөр
The ZL-7918C has an advanced menu for configuring parameters such as egg turning period/duration, air exhaustion period/duration, lamp period/duration, temperature/humidity calibration, and alarm thresholds. Accessing and adjusting these settings typically involves pressing and holding the SET button for several seconds to enter the parameter menu. Consult the comprehensive user manual for a complete list of parameters and their adjustment procedures.
5. Техникалык тейлөө
- Тазалоо: Keep the controller's display and buttons clean using a soft, dry cloth. Avoid using abrasive cleaners or solvents.
- Сенсорго кам көрүү: Ensure temperature and humidity sensors are kept clean and free from debris. Avoid physical damage to the sensor probes.
- Экологиялык шарттар: Operate the controller within the specified environmental conditions (-10 ~ 45°C, <90% RH non-condensing) to ensure longevity and accurate performance.
- Байланыштары: Мезгил-мезгили менен бардык зымдарды байланыштарды текшерип туруңуз, алар бекем жана коррозиядан таза.
6. Кыйынчылыктарды
If you encounter issues with your ZL-7918C controller, consider the following common troubleshooting steps:
- Кубат жок/Дисплей өчүк:
- Check the main power supply to the controller.
- Verify AC-L and AC-N wiring connections (Terminals 13-14).
- Ensure the power source is within the 100-240Vac range.
- Температура/нымдуулук көрсөткүчтөрү туура эмес:
- Check if the temperature and humidity sensors are correctly connected to terminals 1-4.
- Ensure sensors are not damaged or obstructed.
- Verify sensor placement within the incubator for accurate readings.
- Consider calibrating the sensors through the advanced settings if readings are consistently off.
- Heater/Fan/Motor Not Activating:
- Check the wiring for the specific output device (e.g., HEAT1, HUMI, CIR. FAN).
- Ensure the set temperature/humidity is outside the current measured value to trigger the output.
- Verify the output device itself is functional (e.g., heater element, fan motor).
- Check the load capacity of the output; exceeding max wattage/amperage can prevent operation.
- Egg Turning Malfunction:
- Verify connections to RIGHT and LEFT egg turning motor terminals.
- Check the egg turning period and driving time settings in the controller.
- Ensure the egg turning motor is functional.
- Alarm Triggering Frequently:
- Review the alarm threshold settings in the advanced menu.
- Check for stable temperature and humidity conditions within the incubator.
- Ensure sensors are providing accurate readings.
For persistent issues, refer to the full product manual or contact LILYTECH customer support.
7. Колдонуучунун кеңештери
- Сенсордун жайгашуусу: Position temperature and humidity sensors away from direct heat sources or water to get the most accurate readings of the general incubator environment.
- Баштапкы калибрлөө: It is recommended to verify the accuracy of the temperature and humidity sensors against a known good reference thermometer/hygrometer upon initial setup. Adjust calibration settings if necessary.
- Туруктуу чөйрө: For optimal performance, ensure the incubator is placed in a stable environment, free from significant temperature fluctuations or drafts.
- Үзгүлтүксүз мониторинг: Even with automatic control, regularly monitor the incubator's conditions and the controller's display to ensure everything is operating as expected.
- Power Outage Калыбына келтирүү: Familiarize yourself with how the controller behaves after a power outage, especially regarding saved settings.
8. Кепилдик жана колдоо
The LILYTECH ZL-7918C Incubator Controller comes with a 1 жылдык кепилдик сатып алынган күндөн тартып. Бул кепилдик өндүрүштүк кемчиликтерди жана нормалдуу колдонуудагы бузулууларды камтыйт. Кепилдик дооматтары үчүн сатып алганыңыздын далилин сактап коюңуз.
For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Contact information can typically be found on the product packaging or the official LILYTECH webсайт.