The ZL-7835A is an intelligent automatic temperature and humidity controller designed for incubators and similar applications. It features PID control for precise temperature management, high-temperature power-off protection, and comprehensive humidity control. Its multi-functional design includes timed output and over-limit protection, making it suitable for various types of incubators, including pet incubators.
Видео: Бүттүview of the ZL-7835A Incubator Controller and its components.
2. Продукциянын компоненттери
The ZL-7835A controller package typically includes the main control unit, a temperature sensor, a humidity sensor, and necessary wiring. Ensure all components are present and undamaged upon unboxing.

Image: ZL-7835A controller and included accessories.
3. Орнотуу жана орнотуу
3.1 Контроллерди орнотуу
- Cut an opening in your control panel with dimensions of 71mm x 29mm.
- Insert the ZL-7835A controller into the prepared opening.
- Secure the controller using the provided mounting clips on the sides. Push the clips firmly until the controller is snug in place.

Image: ZL-7835A controller side view, illustrating the mounting clips.
3.2 Электр зымдары
Safety Warning: Electrical wiring should only be performed by qualified personnel. Ensure power is disconnected before making any connections to prevent electric shock or damage to the device.
- Бардык туташуулар үчүн тиешелүү зым өлчөгүчтөрүн колдонуңуз.
- Бардык байланыштар коопсуз жана туура изоляцияланганын текшериңиз.
- Avoid routing sensor wires alongside power lines to prevent interference.
- Place temperature and humidity sensors in locations that accurately represent the environment to be controlled.

Image: Electrical wiring diagram for the ZL-7835A controller. Connect power to terminals 6 (N) and 7 (L). Connect the temperature sensor to terminals 1 and 2. Connect the humidity sensor to terminals 4 and 5. R1 (Heating) connects to terminals 1 and 3. R2 (Fan) connects to terminals 4 and 5. R3 (Heater) connects to terminals 8 and 9.
Refer to the wiring diagram above for specific connections:
- Power Supply (100-240Vac): Connect to terminals 6 (Neutral, N) and 7 (Live, L).
- Температура сенсору: Connect to terminals 1 and 2.
- Нымдуулук сенсору: Connect to terminals 4 and 5.
- R1 Output (Heating, 2A 250Vac): Connect to terminals 1 and 3.
- R2 Output (Fan, 3A 250Vac): Connect to terminals 4 and 5.
- R3 Output (Heater, 5A 250Vac): Connect to terminals 8 and 9.
4. Иштөө нускамалары
4.1 Дисплейдин көрсөткүчтөрү
The controller's display provides real-time information and status indicators:
| Icon/Indicator | Description |
|---|---|
| Жылытуу режими | Indicates active heating mode. |
| Жылуулук чыгаруу | Indicates heating output is active. |
| Ойготкуч көрсөткүчү | Flashes when an alarm condition is met. |
| AT | PID auto-tuning in progress. |
| Параметр орнотуу | Indicates parameter setting mode. |
| Timed Output R2 | Indicates timed output R2 is active. |
| Et | NTC temperature sensor error. |
| Eh | Нымдуулук сенсорунун катасы. |
| tHi | Жогорку температура сигнализациясы. |
| tLo | Төмөн температура сигнализациясы. |
| HHi | High humidity alarm. |
| HLo | Low humidity alarm. |
| At1-At4 | PID auto-tuning failure reasons. |
| Suc | PID auto-tuning successful. |
4.2 Негизги операциялар
The controller has several buttons for navigation and setting adjustments:
- Setting Temperature/Humidity: басыңыз S key for 3 seconds. The display will flash. Use the Up жана Төмөн arrow keys to adjust the desired temperature or humidity. Press S ырастоо жана орнотууну сактоо үчүн кайра.
- Accessing System Parameters: басыңыз S key for 3 seconds, then press the P ачкыч. колдонуу Up жана Төмөн arrow keys to navigate through parameters (U10-U99). Press S to select a parameter, adjust its value with Өйдө/Төмөн, жана басыңыз S ырастоо үчүн дагы.
4.3 Parameter Settings (U10-U99)
The ZL-7835A offers a wide range of configurable parameters to fine-tune its operation. Below is a summary of key parameters:
| Code | Функция | Диапазон | Description |
|---|---|---|---|
| U10 | Температуранын жогорку чеги | U11 ~ 99.9°C | Maximum settable temperature. |
| U11 | Температуранын төмөнкү чеги | -40.0 ~ U10°C | Minimum settable temperature. |
| U12 | Башкаруу режими | 0-1 | 0: PID control; 1: Hysteresis control. |
| U13 | Температура гистерезиси | 0.0 ~ 20.0°C | Temperature difference for switching outputs in hysteresis mode. |
| U14 | Температураны оңдоо | -20.0 ~ 20.0°C | Adjusts the displayed temperature to match a reference. |
| U15 | Over-temperature protection upper limit | U15 ~ 0.1°C | Offset for upper temperature protection. |
| U20 | Нымдуулук гистерезиси | 0.1 ~ 20% | Humidity difference for switching outputs. |
| U22 | Нымдуулукту коррекциялоо | -20.0 ~ 20.0% | Adjusts the displayed humidity to match a reference. |
| U40 | Timed R2 off time unit | 0-2 | 0: seconds; 1: minutes; 2: hours. |
| U41 | Timed R2 on time | 1-998 | Duration R2 output is ON. |
| U42 | Timed R2 off time | 1-998 | Duration R2 output is OFF. |
Note: This table is a partial list. Refer to the full manual for all parameter descriptions.
4.4 PID Auto-tuning (AT)
PID auto-tuning helps the controller achieve optimal temperature stability. It is recommended to perform auto-tuning in the actual operating environment with the load connected.
- Ensure the control mode (U12) is set to 0 (PID control).
- Set the desired temperature (SP).
- басып, кармап туруңуз S key for 3 seconds, then press and hold the Up or Төмөн arrow key for 5 seconds. The 'AT' indicator will appear, signifying that auto-tuning has started.
- The controller will cycle through heating and cooling to determine optimal PID parameters. This process can take some time (e.g., 180 minutes).
- Once auto-tuning is complete, the 'AT' indicator will disappear, and 'Suc' will be displayed, indicating successful tuning. The controller will then operate with the newly optimized parameters.
Important: Do not interrupt the auto-tuning process. If auto-tuning fails, an error code (At1-At4) will be displayed. In such cases, check the setup and retry.
5. Control Functions
5.1 Температураны көзөмөлдөө
- PID Control (U12=0): Utilizes a PID algorithm for precise temperature regulation, with R3 acting as the primary heating output.
- Temperature Over-limit Protection (U46=2, 4, 6, 7): If the measured temperature exceeds the set temperature plus parameter U15, output R2 (fan) will activate. If the temperature drops below the set temperature plus parameter U16, R2 will deactivate after a 3-second delay.
- High Temperature Alarm (Secondary Protection): If the measured temperature exceeds the set temperature plus parameter U17, the power to the heater will be cut, the display will flash 'HH', and the buzzer will sound.
- Төмөн температура сигналы: If the measured temperature falls below the set temperature minus parameter U18, the buzzer will sound.
5.2 Нымдуулукту көзөмөлдөө
- Нымдуулукту көзөмөлдөө: If the measured humidity exceeds the set humidity minus parameter U20, output R1 will activate. If the humidity drops below the set humidity minus parameter U20, R1 will deactivate.
- Humidity Over-limit Protection (U46=3, 5, 6, 7): If the measured humidity exceeds the set humidity plus parameter U23, output R2 will activate. If the humidity drops below the set humidity plus parameter U24, R2 will deactivate after a 3-second delay.
- High Humidity Alarm (Secondary Protection): If the measured humidity exceeds the set humidity plus parameter U25, the power to the humidifier will be cut, the display will flash 'HH', and the buzzer will sound.
- Төмөн нымдуулук сигналы: If the measured humidity falls below the set humidity minus parameter U26, the buzzer will sound.
5.3 Timed Output R2
The R2 output can be configured for timed operation using parameters U41 (ON time) and U43 (OFF time), with the time unit set by U40.
6. Техникалык тейлөө
- Тазалоо: Regularly clean the controller's display and buttons with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Сенсорго кам көрүү: Keep the temperature and humidity sensors clean and free from debris. Avoid exposing them to direct water or extreme physical stress.
- Туташуу текшерүү: Мезгил-мезгили менен бардык зымдарды байланыштарды текшерип, алар бекем жана коррозияга учурабайт.
- Калибрлөө: If you suspect sensor inaccuracy, use the temperature (U14) and humidity (U22) correction parameters to adjust readings against a known accurate reference.
- Заводдун баштапкы абалга келтирүү: To restore all system parameters to their factory default values, press the S key for 3 seconds, then press the Төмөн arrow key for 5 seconds. The display will show 'Suc' upon successful reset.
7. Кыйынчылыктарды
This section addresses common issues and alarm conditions you might encounter.
7.1 Сигнализациянын көрсөтмөлөрү
The controller will sound a buzzer and display specific codes for alarm conditions:
- Ойготкуч сигналы: The buzzer will sound for high/low temperature, high/low humidity, and sensor errors.
- Системаны калыбына келтирүү: If the system recovers from an alarm condition, the buzzer will stop.
- Үндү кол менен өчүрүү: Press any key to mute the buzzer during an alarm.
7.2 Жалпы маселелер жана чечимдер
| Көйгөй/Ката коду | Мүмкүн себеп | Чечим |
|---|---|---|
| Et (NTC Sensor Error) | Temperature sensor open circuit, short circuit, or damage. | Check sensor connection. Replace sensor if damaged. |
| Eh (Humidity Sensor Error) | Humidity sensor open circuit, short circuit, or damage. | Check sensor connection. Replace sensor if damaged. |
| tHi / HHi | Temperature/Humidity exceeds high alarm limit. | Check heating/humidifying elements. Verify set points and alarm parameters (U17, U25). Ensure proper ventilation. |
| tLo / HLo | Temperature/Humidity falls below low alarm limit. | Check heating/humidifying elements. Verify set points and alarm parameters (U18, U26). |
| At1-At4 (PID Auto-tuning Failure) | PID auto-tuning failed due to unstable environment, incorrect wiring, or improper settings. | Ensure stable environment, correct wiring, and appropriate set points. Retry auto-tuning. |
| Контроллер жооп бербей жатат | No power, loose connections, or internal fault. | Check power supply. Verify all wiring. Contact support if issue persists. |
8. Техникалык шарттар
| Өзгөчөлүк | Спецификация |
|---|---|
| Электр камсыздоо | 100-240Vac, 50 / 60Hz |
| Температура сенсору | NTC, R25=10K, B25/50=3470K |
| Нымдуулук сенсору | 0-100% RH (конденсация жок) |
| Output R1 (Heating) | 5A, 250Vac (resistive load) |
| Output R2 (Fan) | 3A, 250Vac (resistive load) |
| Output R3 (Heater) | 5A, 250Vac (resistive load) |
| Иштөө чөйрөсү | -10°C to 45°C, 5% to 85%RH |
| Коргоо деңгээли | IP65 (алдыңкы панель) |
| Панелдин өлчөмү | 78мм (L) x 34.5mm (W) |
| Ачылышынын өлчөмү | 71мм (L) x 29mm (W) |
9. Колдонуучунун кеңештери
- Туруктуу чөйрө: For best performance, ensure the controller is installed in a stable environment, away from direct sunlight, excessive vibrations, or extreme temperature fluctuations.
- Сенсордун жайгашуусу: Position the temperature and humidity sensors centrally within the incubator or controlled space to get the most accurate readings. Avoid placing them too close to heating elements or water sources.
- Үзгүлтүксүз мониторинг: Even with automatic control, it's good practice to periodically monitor the incubator's conditions and the controller's readings to ensure everything is operating as expected.
- Кубаттуулуктун туруктуулугу: Use a stable power source. Fluctuations can affect the controller's performance and the accuracy of its readings.
- Колдонуудан мурун сыноо: Before placing valuable contents in the incubator, run the controller for a full cycle to verify that it maintains the desired temperature and humidity accurately.
10. Кепилдик жана колдоо