The Square D B075 Bolt-On Hub is a robust metal component designed for secure conduit connections in electrical systems. Its unique design features an off-center conduit threaded opening and elongated mounting holes, which facilitate easier installation and adjustment, potentially reducing the need for complex conduit offsets and bends. This hub is specifically engineered for use with Square D load centers, CSED devices, and safety switches, ensuring compatibility and reliable performance. It is a Type B size hub and holds both UL and CSA safety listings, confirming its adherence to stringent safety and quality standards.

1-сүрөт: Негизги view of the Square D B075 Bolt-On Hub. This hub is designed for secure electrical conduit connections.
Негизги өзгөчөлүктөрү
- Designed for use in Square D load centers, CSED devices, and safety switches.
- Suitable for outdoor load centers and safety switches, ensuring versatility.
- UL- and CSA safety listed, confirming compliance with safety standards.
- Type B size, ensuring compatibility with specified Square D equipment.
- Features an off-center conduit threaded opening and elongated mounting holes for simplified installation and adjustment.

Figure 2: Visual representation of the key features and certifications of the B075 hub, including its 3/4 inch bolt-on design, suitability for various electrical panels, and UL/CSA listing.
Техникалык шарттар
| Атрибут | Деталь |
|---|---|
| Модель номери | B075 |
| Материал | Металл |
| Түс | Silver |
| Өлчөмдөрү (L x W x Y) | 3.13 x 4.13 x 1.4 дюйм |
| Элемент Салмагы | 0.01 унция |
| Туташтыргыч түрү | Редуктор |
| Thread Size | 3 дюйм |
| Thread Type | NPT |
| Даана саны | 1 |
| Сертификаттар | UL- and CSA listed |

Figure 3: Detailed dimensions of the Square D B075 Bolt-On Hub, showing its length, width, and height for accurate planning and installation.
Орнотуу жана орнотуу
The Square D B075 Bolt-On Hub is designed for straightforward installation into compatible Square D load centers, CSED devices, and safety switches. Its off-center threaded opening and elongated mounting holes are key features that simplify the alignment and attachment process, reducing the need for custom conduit bends or offsets.
Орнотуу кадамдары:
- Биринчи коопсуздук: Ensure all power to the load center or device is disconnected at the main breaker before beginning any installation. Verify with a voltage сыноочу.
- Ачылышын даярдоо: Identify the appropriate Type B opening on your Square D load center, CSED device, or safety switch where the hub will be installed.
- Хабды жайгаштырыңыз: Align the elongated mounting holes of the B075 hub with the corresponding screw holes on the device. The off-center threaded opening allows for flexibility in conduit routing.
- Secure the Hub: Use appropriate fasteners (not included with the hub, typically provided with the load center or device) to securely bolt the hub to the enclosure. Ensure a tight fit to maintain the rain-tight integrity, especially for outdoor applications.
- Түтүктү туташтыруу: Thread the rigid conduit directly into the 3-inch NPT threaded opening of the hub. Ensure the conduit is properly seated and tightened to prevent water ingress and maintain electrical continuity.
- Акыркы текшерүү: After installation, visually inspect all connections for tightness and proper alignment. Ensure no gaps or loose components are present.
For a visual guide on load center accessories and their installation, please refer to the video below. This video provides additional context on various components, including hubs, ground bars, neutral lugs, filler plates, and cover screws, which are often used in conjunction with load centers.
Video: Load Center Accessories. This video provides an overview of various accessories, including hubs, ground bars, neutral lugs, filler plates, and cover screws, and their role in electrical installations.

Figure 4: Illustration showing the compatibility of the 3/4 inch B075 Bolt-On Hub with Square D outdoor or N3R Homeline and QO load centers and safety switches that have "B" type openings.
Иштөө принциптери
The Square D B075 Bolt-On Hub functions as a critical interface for connecting rigid electrical conduit to Square D load centers, CSED devices, and safety switches. Its primary role is to provide a secure, rain-tight entry point for electrical wiring, protecting the internal components of the electrical enclosure from environmental elements such as moisture and dust. By facilitating a direct and sealed connection, the hub helps maintain the integrity of the electrical system and ensures safe operation.
The design of the hub, with its threaded opening, allows for easy and reliable attachment of conduit, ensuring that the electrical conductors are properly routed and protected as they enter the enclosure. This contributes to the overall safety and longevity of the electrical installation.
Техникалык тейлөө
Given that the Square D B075 Bolt-On Hub is a passive mechanical component, it requires minimal maintenance. Regular inspection is recommended to ensure its continued integrity and performance.
Сунушталган техникалык тейлөө текшерүүлөрү:
- Визуалдык текшерүү (жыл сайын): Periodically inspect the hub and its connection to the electrical enclosure for any signs of physical damage, corrosion, or wear. Check for cracks, deformities, or loose connections.
- Тыюулугун текшерүү: Ensure that the bolts securing the hub to the enclosure and the conduit threaded into the hub remain tight. Loose connections can compromise the rain-tight seal and electrical safety.
- Айлана-чөйрөнү коргоо мөөрү: For outdoor installations, verify that the rain-tight seal around the hub and conduit entry point is intact and free from degradation. Address any signs of water ingress immediately.
- Тазалык: Keep the exterior of the hub free from excessive dirt, debris, or corrosive substances that could accelerate wear or compromise its material integrity.
If any damage or significant wear is observed, the hub should be replaced by a qualified electrician to ensure the safety and compliance of the electrical system.
Проблемаларды чечүү
The Square D B075 Bolt-On Hub is a straightforward component, and issues are typically related to improper installation or physical damage. Here are common troubleshooting scenarios:
Жалпы маселелер жана чечимдер:
- Issue: Water or Moisture Inside Enclosure
- Себеби: Improperly tightened hub bolts or conduit connection, damaged hub, or degraded seal.
- Чечим: Disconnect power. Inspect the hub for cracks or damage. Ensure all bolts are securely tightened. Re-thread and tighten the conduit connection. If the hub is damaged, replace it.
- Issue: Loose Conduit Connection
- Себеби: Insufficient tightening during installation or vibration over time.
- Чечим: Disconnect power. Carefully re-tighten the conduit into the hub's threaded opening. Ensure it is snug but do not overtighten, which could strip threads.
- Issue: Difficulty Aligning Hub During Installation
- Себеби: Conduit not properly aligned with the enclosure opening, or incorrect hub type.
- Чечим: The B075 hub features elongated mounting holes and an off-center opening to aid alignment. Adjust the conduit run as needed. Confirm the hub is a Type B size, compatible with your Square D device.
Always ensure power is disconnected before attempting any inspection or repair. If you are unsure about any step, consult a qualified electrician.
Кепилдик жана колдоо
For information regarding the warranty of your Square D B075 Bolt-On Hub, please refer to the documentation provided with your original purchase or visit the official Schneider Electric webсайт. Кепилдик шарттары жана эрежелери аймакка жана сатып алынган күнгө жараша өзгөрүшү мүмкүн.
Should you require technical support, have questions about installation, or need assistance with troubleshooting, please contact Schneider Electric customer service. Their contact information can typically be found on their official webсайтында же продуктунун таңгагында.
Note: Always ensure that any installation, maintenance, or repair work is performed by a qualified and licensed electrician to comply with local electrical codes and safety regulations.