ICM башкаруу элементтери ICM203

ICM Controls ICM203 кечиктирүү таймеринин колдонуу боюнча колдонмосу

1. Киришүү

The ICM Controls ICM203 is a universal voltage delay on break timer designed to protect compressors from damage caused by rapid short cycling. This anti-short cycle relay ensures that the compressor remains off for a set period after power interruption, allowing system pressures to equalize before restarting. It operates across a wide voltage range and features an adjustable delay setting.

Фронт view of the ICM Controls ICM203 Delay on Break Timer, showing the adjustable dial, wiring terminals, and product labeling.

Фронт view of the ICM Controls ICM203 Delay on Break Timer, showing the adjustable dial, wiring terminals, and product labeling.

2. Негизги өзгөчөлүктөрү

  • Компрессордук коргоо: Prevents damage from rapid short cycling with built-in lockout safety.
  • Adjustable Delay: Set custom delay time from 1.8 to 600 seconds for flexible system control.
  • Wide Voltage диапазону: Operates on 18–240 VAC, suitable for a broad range of HVAC and refrigeration applications.
  • Жөнөкөй орнотуу: Easy 2-wire hookup for quick and reliable setup.
  • Туруктуу жана ишенимдүү: Solid-state design ensures long-lasting performance in demanding environments.

3. Техникалык шарттар

СпецификацияНарк
Модель номериICM203
Киргизүү көлөмүtage18-240 VAC
Жөнгө салынуучу кечигүү1.8–600 Seconds (0.03–10 Minutes)
Жүктөө агымы1.5 Amp Макс
Продукциянын өлчөмдөрү2"D x 2"W x 1.25"H (5.08 см x 5.08 см x 3.18 см)
Элемент Салмагы1.6 унция (45.36 грамм)
Орнотуулардын саны1 (adjustable dial)
ӨндүрүүчүICM башкаруу элементтери
Side view of the ICM Controls ICM203 Delay on Break Timer, illustrating its depth and mounting hole.

Side view of the ICM Controls ICM203 Delay on Break Timer, illustrating its depth and mounting hole.

4. Орнотуу

Коопсуздук эскертүүсү: Installation of this device involves working with electrical components and potentially high voltages. To prevent electric shock or damage to equipment, installation should only be performed by a qualified professional or person familiar with HVAC electrical systems. Always disconnect power to the unit before beginning installation.

Close-up of the ICM Controls ICM203 Delay on Break Timer being wired, showing the red jumper wire for 120/240 VAC selection.

Close-up of the ICM Controls ICM203 Delay on Break Timer being wired, showing the red jumper wire for 120/240 VAC selection.

Жалпы орнотуу кадамдары:

  1. Кубатты өчүрүү: Ensure all power to the HVAC unit or compressor is completely disconnected at the circuit breaker.
  2. Locate Compressor Contactor: Identify the low voltage control circuit for the compressor contactor.
  3. Зым туташуу: The ICM203 features a simple 2-wire hookup. Connect the two wires of the ICM203 in series with the 24 VAC control circuit that energizes the compressor contactor coil. This means the timer will interrupt the control voltage to the contactor.
  4. Тtage Тандоо (эгер бар болсо): The ICM203 is universal voltage. For 120/240 VAC applications, ensure the red jumper wire is correctly configured or cut as indicated on the device label, if necessary for your specific voltage. Refer to the device's printed instructions for precise wiring diagrams.
  5. Монтаждоо: Securely mount the ICM203 in a suitable location within the control panel or near the compressor, ensuring it is protected from environmental elements.
  6. Күчтү калыбына келтирүү: Once wiring is complete and verified, restore power to the unit.
Hands installing the ICM Controls ICM203 Delay on Break Timer into an HVAC unit, showing wiring connections.

Hands installing the ICM Controls ICM203 Delay on Break Timer into an HVAC unit, showing wiring connections.

Symbol of a lightning bolt with text 'Requires installation by a professional or qualified person'.

This device requires installation by a professional or qualified person due to electrical safety considerations.

5. Операция

The ICM203 operates automatically once installed. Its primary function is to enforce a delay before the compressor can restart after a power interruption or a call for cooling is removed and then immediately reapplied. This delay protects the compressor from short cycling.

Adjusting the Delay Time:

The delay time is adjustable using the red dial located on the front of the unit. The dial is marked in minutes, typically ranging from 0.03 minutes (approximately 1.8 seconds) to 10 minutes (600 seconds). To adjust the delay:

  1. Locate the Dial: Find the red adjustment dial on the face of the ICM203.
  2. Rotate to Desired Setting: Carefully rotate the dial using a small screwdriver or similar tool to align the indicator with the desired delay time in minutes. Common settings are often between 3 to 5 minutes to allow sufficient pressure equalization.
  3. Ишти текшерүү: After setting, observe the system's behavior to ensure the delay functions as intended before the compressor restarts.

6. Техникалык тейлөө

The ICM Controls ICM203 Delay on Break Timer is a solid-state device designed for reliable, maintenance-free operation. No routine maintenance is required. Periodically, ensure that electrical connections remain secure and free from corrosion. If the unit appears damaged or is not functioning correctly, it should be inspected by a qualified technician.

7. Кыйынчылыктарды

If the ICM203 is not functioning as expected, consider the following:

  • No Delay: Verify the dial is set to a non-zero delay time. Ensure the unit is correctly wired in series with the compressor contactor's control circuit.
  • Компрессор иштебей жатат: Check for proper power supply to the ICM203. Ensure all wiring connections are secure. If the delay period has elapsed and the compressor still does not start, investigate other components of the HVAC system.
  • Incorrect Delay Time: Re-adjust the dial to the desired setting. Note that the adjustment at the very low end of the scale can be sensitive.
  • Unit Damage: Visually inspect the ICM203 for any signs of physical damage or burning. If damaged, replace the unit.

For persistent issues, it is recommended to consult a qualified HVAC technician.

8. Кепилдик маалыматы

ICM Controls products are known for their quality and reliability. The ICM203 is manufactured in the USA and comes with a warranty designed to ensure customer satisfaction. For specific details regarding the warranty period and terms, please refer to the official ICM Controls webсайтка же техникалык колдоо менен байланышыңыз.

Seal indicating 'BEST WARRANTY IN THE INDUSTRY' and 'MADE IN AMERICA' with a US flag.

ICM Controls products are proudly Made in America and backed by a strong industry warranty.

9. Техникалык колдоо

For technical assistance, installation questions, or troubleshooting support, please contact ICM Controls Technical Support.

Text displaying 'Please call 1-800-365-5525 Opt. 8 Mon-Fri 8-5 EST for Technical Support'.

Contact ICM Controls Technical Support for assistance.

Телефон: 1-800-365-5525, Option 8

Сааттары: Monday - Friday, 8:00 AM - 5:00 PM EST

Тектеш документтер - ICM203

Preview ICM450A жана ICM450A PLUS+ программалануучу 3 фазалуу линия вольтуtagэлектрондук мониторлорду орнотуу жана иштетүү боюнча колдонмо
Бул колдонмодо ICM450A жана ICM450A PLUS+ программалануучу 3 фазалуу линия вольтунун орнотуусу, иштеши жана мүнөздөмөлөрү боюнча толук маалымат берилген.tagэлектрондук мониторлор. Ал фазанын тең салмаксыздыгынан коргоо, ашыкча/азыраак volt сыяктуу функцияларды камтыйтtage коргоосу, тыныгуудагы кечигүү таймери жана PLUS+ модели үчүн Modbus байланышы. Кыйынчылыктарды чечүү боюнча кеңештер жана бир жылдык чектелген кепилдик да камтылган.
Preview ICM493 Программалануучу бир фазалуу томtagЭлектрондук мониторду чыңалуудан коргоо менен орнотуу боюнча колдонмо
ICM493 программалануучу бир фазалуу вольтметрди орнотуу, иштетүү жана колдонуу боюнча кеңири колдонмоtagЭлектрондук монитор, чыңалуудан коргоо функциясы менен. Коопсуздукту, орнотуу кадамдарын, калибрлөөнү, спецификацияларды жана HVAC жана өнөр жай колдонмолору үчүн баскыч функцияларын камтыйт.
Preview ICM870 9A/16A Soft Start Installation and Operation Guide
Detailed installation, operation, and application guide for the ICM870 9A/16A soft start controller, including specifications, features, fault codes, and wiring diagram. Designed for HVAC, marine, and RV applications.
Preview ICM870-32A Soft Start Controller: Installation and Operation Guide
Comprehensive guide to the ICM870-32A soft start motor controller from ICM Controls. Learn about its features, specifications, installation, operation, and troubleshooting for HVAC, RV, and marine applications.
Preview ICM402 3-фазалык монитор: өзгөчөлүктөрү, спецификациялары жана зымдары
ICM402 3-фазалык монитор жөнүндө толук маалымат, анын ичинде анын өзгөчөлүктөрү, техникалык мүнөздөмөлөрү жана электр өткөргүч схемалары. Бул аппарат компрессорлор үчүн идеалдуу фазаны жоготуудан, фазаны өзгөртүүдөн жана фазалык тең салмаксыздыктан коргойт.
Preview ICM-UFPT-2 жана ICM-UFPT-5 универсалдуу функциялуу программалануучу таймерлерди орнотуу жана иштетүү боюнча колдонмо
Оңой орнотуу жана программалоо үчүн NFC технологиясы менен жабдылган ICM Controls ICM-UFPT-2 жана ICM-UFPT-5 универсалдуу функциялуу программалануучу таймерлер үчүн комплекстүү орнотуу, иштетүү жана колдонуу боюнча колдонмо.