Продукт бүттүview
The Leviton T5320-W is a 15 Amp, 125 Volt, tamper-resistant duplex receptacle designed for residential applications. This device features a robust thermoplastic construction for durability and a shallow design to maximize wiring room within electrical boxes. Its tamper-resistant design incorporates an internal shutter mechanism that blocks access to the contacts unless a two-prong plug is inserted, enhancing safety by preventing the insertion of foreign objects.

Сүрөт: алдыңкы view of the Leviton 15 Amp 125 Volt Tamper Resistant Duplex Receptacle, Model T5320-W.
Коопсуздук маалыматы
ЭСКЕРТҮҮ: To avoid fire, shock, or death, always turn off power at the circuit breaker or fuse box before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.
- Орнотуудан же тейлөөдөн мурун ар дайым кубат менен камсыздоонун өчүрүлгөнүн текшериңиз.
- Use only 14-gauge solid copper wire for Quickwire™ terminations. For larger gauge wires or stranded wire, use side wiring or back wiring methods.
- Do not use this device with aluminum wiring unless appropriate CO/ALR type connectors are used.
- Бул продукт сизди Калифорния штатында рак жана тубаса кемтиктер же башка репродуктивдик зыян келтирүүчү химиялык заттарга дуушар кылышы мүмкүн. Көбүрөөк маалымат алуу үчүн, төмөнкү дарекке өтүңүз www.P65Warnings.ca.gov.
Орнотуу жана орнотуу
Follow these steps for proper installation of your Leviton duplex receptacle:
- Кубатты өчүрүү: Locate the circuit breaker or fuse that controls the outlet you are replacing or installing. Turn off the power. Verify power is off using a voltage сыноочу.
- Зымдарды даярдоо: Strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the circuit wires. Ensure wires are straight and free of nicks.
- Зымдарды туташтыруу:
- Жер зымы (жашыл же жылаңач жез): Жашыл жерге туташтыргыч бурамага туташтырыңыз.
- Ысык зымдар (кара же кызыл): Connect to the brass-colored screws.
- Neutral Wires (White): Connect to the silver-colored screws.
- Quickwire™ Terminations (14-Gauge Solid Copper ONLY): For 14-gauge solid copper wire, push the stripped end firmly into the small holes on the back of the receptacle until it stops. Ensure no bare wire is exposed.
- Каптал зымдар: For larger gauge wires or stranded wire, wrap the stripped wire clockwise around the appropriate screw terminal and tighten securely.
- Суу сактагыч: Carefully fold the wires into the electrical box and secure the receptacle to the box using the mounting screws provided.
- Wallplate орнотуу: Attach the wallplate (sold separately) over the receptacle.
- Күчтү калыбына келтирүү: Электрди өчүргүчтөн же сактагыч кутудан кайра күйгүзүңүз.
For a visual guide on Quickwire™ terminations, please refer to the video below:
Video: Leviton Answer Series: Quickwire Terminations. This video demonstrates the correct method for using Quickwire™ terminations with 14-gauge solid copper wire for Leviton devices.

Сүрөт: Артка view of a Leviton receptacle, illustrating the Quickwire™ termination holes and side screw terminals for wiring connections.
Иштөө нускамалары
To use the receptacle, simply insert the plug of your electrical device into one of the two outlets. The tamper-resistant shutters will open to allow the plug to enter. Ensure the plug is fully inserted for a secure connection. When removing a plug, pull it straight out from the receptacle.
Техникалык тейлөө
The Leviton T5320-W receptacle requires minimal maintenance. Periodically inspect the receptacle and wallplate for any signs of damage, such as cracks, discoloration, or loose connections. Clean the surface with a soft, damp cloth. Do not use abrasive cleaners or solvents. If any damage is observed, turn off power at the circuit breaker and replace the receptacle.
Проблемаларды чечүү
- Розеткага электр кубаты жок:
- Чынжырдын автоматтык өчүргүчүн же сактагычын текшериңиз. Эгерде өчүп калса, баштапкы абалга келтириңиз же күйүп кетсе, алмаштырыңыз.
- Ensure all wire connections are secure. Turn off power before checking connections.
- Plug Does Not Insert Easily:
- тamper-resistant feature requires both prongs of a plug to be inserted simultaneously and with even pressure to open the internal shutters. Do not force the plug.
- Ensure the plug is correctly oriented.
- Loose Plug Connection:
- If plugs feel loose or fall out easily, the receptacle may be worn and should be replaced. Turn off power before replacement.
If issues persist after troubleshooting, consult a qualified electrician.
Техникалык шарттар
| Бренд | Левитон |
| Модел | T5320-W |
| Ampөчүрүү | 15 Amps |
| Тtage | 125 вольт |
| Жалпы электр розеткалары | 2 |
| Материал | Пластик |
| Түс | Ак |
| Продукциянын өлчөмдөрү (L x W) | 15"L x 8.37"W |
| Элемент Салмагы | 0.14 фунт |
| Туташтыргыч түрү | Нема 5-15 |
| Specification Met | NEC |
Кепилдик жана колдоо
This Leviton receptacle comes with a 2 жылдык Чектелген Кепилдик. For warranty claims or technical support, please contact Leviton customer service. Keep your purchase receipt as proof of purchase.