1. Киришүү
This manual provides essential information for the safe and proper installation, operation, and maintenance of the ABB PowerMark Plus 125 Amp 4-Space 8-Circuit Single-Phase Indoor Main Lug Circuit Breaker Panel, model TL412CP. This dependable load center is designed for residential applications, ensuring safe and efficient electrical distribution and protection.
For your safety, it is crucial to purchase only genuine, ABB-manufactured electrical products. Counterfeit and non-authentic products may fail to meet safety standards, posing significant risks. Always verify product authenticity and certifications.
2. Коопсуздук боюнча маанилүү маалымат
WARNING: Risk of Electric Shock or Fire. Installation and servicing of this electrical panel must be performed by qualified, licensed electricians only. Disconnect power at the main service panel before working on or near this equipment.
- Always ensure the main power supply is disconnected before any installation, maintenance, or troubleshooting.
- Бул продукт ички колдонуу үчүн гана арналган.
- нымдуу же г орнотууга болбойтamp жерлер.
- Бардык зымдар улуттук жана жергиликтүү электр эрежелерине ылайык келээрин текшериңиз.
- This load center is UL listed and ANSI certified, ensuring it meets stringent safety standards.
- Сунуш 65 Эскертүү: Бул продукт Калифорния штатында рак жана тубаса кемтик же башка репродуктивдүү зыян келтирүүчү химиялык заттарды камтышы мүмкүн.
3. Продукциянын өзгөчөлүктөрү
- Reliable 125 Amp Indoor Main Lug Load Center: A dependable 125 Amp, 4-Space, 8-Circuit main lug load center designed for residential applications, ensuring safe and efficient electrical distribution.
- Rust-Resistant Galvanized Steel Box: Features a galvanized steel box for maintenance-free operation, resisting rust and corrosion.
- High Conductivity: The tin-plated copper buss bar supports high conductivity, ensuring reliable and efficient performance.
- Оңой орнотуу: Comes with factory-installed main lugs and supports both surface and flush installations. Its one-piece interior design allows for easy removal and re-installation.
- Meets Highest Safety Standards: UL listed and ANSI certified, accommodating standard GFCI and AFCI circuit breakers for top-tier protection.
4. Орнотуу жана орнотуу
Installation of this circuit breaker panel requires specialized knowledge and adherence to electrical safety standards. It is strongly recommended that installation be performed by a qualified and licensed electrician.
4.1 Орнотууга чейинки текшерүүлөр
- Verify that the product specifications match your electrical system requirements (120/240 VAC, 125 Amp, single-phase, 3-wire).
- Бардык керектүү шаймандар жана коопсуздук жабдуулары бар экендигин текшериңиз.
- Confirm the installation location is dry, accessible, and provides adequate ventilation.
4.2 Панелди орнотуу
The ABB TL412CP supports both surface and flush installations. The galvanized steel box is designed for durability and ease of mounting.

4.2.1-сүрөт: Артка view of the panel, illustrating mounting points for secure installation.
4.3 Зымдарды туташтыруу
The panel features factory-installed main lugs and a tin-plated copper buss bar for high conductivity. All wiring should be done according to the provided wiring diagram (not included in this manual, refer to product packaging or professional electrician) and local electrical codes.

4.3.1-сүрөт: Интерьер view of the panel, highlighting the main lugs and bus bar connections.

4.3.2-сүрөт: деталдуу интерьер view showing the layout for circuit breaker installation.
4.4 Капка орнотуу
Once all wiring and circuit breakers are installed, secure the panel cover. The cover protects internal components and prevents accidental contact with live parts.

Сүрөт 4.4.1: Алдыңкы view of the panel with the protective cover in place.
5. Иштөө нускамалары
The ABB PowerMark Plus panel serves as the central distribution point for your home's electrical circuits. Individual circuit breakers within the panel protect specific circuits from overcurrents and short circuits.
5.1 Understanding Circuit Breakers
Each circuit breaker controls a specific circuit in your home. When an overload or short circuit occurs, the breaker will "trip" (move to the OFF or middle position) to interrupt the flow of electricity and prevent damage or fire.
5.2 Ачууланган өчүргүчтү баштапкы абалга келтирүү
- Identify the Tripped Breaker: Locate the breaker that is in the OFF or middle position.
- ӨЧҮРҮҮ: Firmly push the breaker handle completely to the OFF position.
- Күйгүзүү: Firmly push the breaker handle completely to the ON position.
- If the breaker immediately trips again, there may be an electrical fault or overload on the circuit. Do not attempt to reset it repeatedly. Consult a qualified electrician.
It is advisable to label each circuit breaker clearly to identify which areas or appliances they control.
6. Техникалык тейлөө
The ABB PowerMark Plus circuit breaker panel is designed to be largely maintenance-free due to its rust-resistant galvanized steel construction. However, periodic checks are recommended to ensure continued safe operation.
- Жылдык текшерүү: It is recommended to have a qualified electrician inspect your electrical panel annually to check for loose connections, signs of wear, or potential issues.
- Таза кармоо: Ensure the area around the electrical panel is always clear of obstructions to allow for proper ventilation and access.
- Тазалоо: If necessary, gently wipe the exterior of the panel with a dry, clean cloth. Do not use liquids or abrasive cleaners. Ensure power is off before cleaning.
7. Кыйынчылыктарды
Most issues related to a circuit breaker panel involve tripped breakers. If you experience persistent electrical problems, always consult a qualified electrician.
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Автоматтык өчүргүч тез-тез иштен чыгат. | Ашыкча жүктөлгөн чынжыр, кыска туташуу же жерге туташуу. | Reduce load on the circuit. Unplug appliances. If problem persists, contact a qualified electrician. |
| Үйдүн бүтүндөй бөлүгүнө электр энергиясы жок. | Main breaker tripped, or issue with utility supply. | Check if the main breaker is tripped. If not, contact your utility company or a qualified electrician. |
| Burning smell or unusual noises from panel. | Loose connections, faulty wiring, or damaged components. | IMMEDIATELY turn off main power if safe to do so and contact a qualified electrician. Do not attempt to fix yourself. |
8. Техникалык шарттар
| Атрибут | Нарк |
|---|---|
| Бренд | ABB |
| Модель номери | TL412CP (Item model number: TL412C) |
| Продукциянын өлчөмдөрү | 13.6"L x 4.47"W x 3"H |
| AC адаптер агымы | 125 Amps |
| Материал | Galvanized Steel (Box), Plastic (Cover), Tin-plated Copper (Buss Bar) |
| Circuits саны | 8 |
| Фаза түрү | Бир фазалуу |
| Тtage | 120/240 Вольт AC |
| Сертификаттар | UL Listed, ANSI Certified |
| UPC | 783164208306, 783164396782 |
9. Кепилдик жана колдоо
This product comes with a manufacturer's warranty. For specific warranty information, please contact ABB customer service directly or refer to the official ABB website. ABB acquired GE's Industrial Solutions business in 2018 and continues to manufacture GE, GE by ABB, and ABB branded products under a license from GE.
For technical support, installation guidance, or any product-related inquiries, please reach out to ABB customer support.
ABB расмий өкүлү Webсайт: https://new.abb.com/us