SILENT KNIGHT PSSA

SILENT KNIGHT PS-SA Single Action Pull Station User Manual

Model: PSSA

Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the SILENT KNIGHT PS-SA Single Action Pull Station. This device is designed for use in fire alarm systems to manually initiate an alarm. It features screw terminal connections, a key lock reset, and integrated operating instructions with Braille text for accessibility.

Сураныч, туура иштешин жана коопсуздугун камсыз кылуу үчүн орнотуу жана иштетүү алдында бул колдонмону кылдат окуп чыгыңыз.

Продукт бүттүview

SILENT KNIGHT PS-SA Single Action Pull Station

Сүрөт 1: Алдыңкы view of the SILENT KNIGHT PS-SA Single Action Pull Station. The device is red with "FIRE" prominently displayed at the top. Below it is a black pull-down handle with "PULL DOWN" and directional arrows. The bottom left features the "SILENT KNIGHT" logo, and the bottom right has a keyhole for resetting the station.

The PS-SA pull station is a critical component in fire safety systems, allowing occupants to manually trigger an alarm in case of a fire emergency. Its robust design ensures reliable operation and easy reset capabilities.

Орнотуу жана орнотуу

1. Коопсуздук чаралары

  • Always disconnect power to the fire alarm control panel before beginning installation.
  • Бардык зымдар жергиликтүү жана улуттук электр эрежелерине ылайык келээрин текшериңиз.
  • Орнотуу квалификациялуу кызматкерлер тарабынан гана аткарылышы керек.

2. Монтаждоо

  1. Select a visible and accessible location, typically near exits, in accordance with local fire codes.
  2. Mount the pull station to a standard single-gang or double-gang electrical box using appropriate screws.
  3. Ensure the device is securely fastened to prevent movement.

3. Электр зымдары

  • The PS-SA features screw terminal connections. Refer to the fire alarm control panel's manual for specific wiring diagrams.
  • Connect the initiating device circuit (IDC) wires to the designated terminals.
  • Ensure all connections are tight and secure to prevent intermittent operation.
  • Verify correct polarity before applying power.

Иштөө нускамалары

1. Ойготкучту иштетүү

In the event of a fire, firmly grasp the handle marked "PULL DOWN" and pull it downwards until it latches in the activated position. This action will send an alarm signal to the fire alarm control panel, initiating the building's alarm sequence.

Warning: Only activate the pull station in a genuine emergency or during authorized testing.

2. Тартуу станциясын баштапкы абалга келтирүү

After activation, the PS-SA pull station must be reset using the provided key. Insert the key into the keyhole located at the bottom right of the device and turn it to reset the pull handle to its original, non-alarm position. Remove the key once reset is complete.

The fire alarm control panel will also need to be reset according to its specific instructions to clear the alarm condition.

Техникалык тейлөө

Regular maintenance ensures the reliable operation of your SILENT KNIGHT PS-SA pull station.

1. Күнүмдүк текшерүү

  • Visually inspect the pull station monthly for any signs of damage, tampering, or obstruction.
  • Ensure the "PULL DOWN" handle moves freely and latches correctly when activated (during authorized testing).
  • Check that the keyhole mechanism operates smoothly for resetting.

2. Сыноо

The pull station should be tested annually, or more frequently as required by local codes and regulations, by a qualified fire alarm technician. Testing typically involves:

  1. Notifying building occupants and the monitoring station of the test.
  2. Activating the pull station to verify it sends an alarm signal to the control panel.
  3. Resetting the pull station with the key.
  4. Verifying the alarm clears from the control panel.

3. Тазалоо

Тартуу станциясынын сыртын жумшак, гamp кездеме. Абразивдүү тазалагычтарды же эриткичтерди колдонбоңуз, анткени алар финишке же ички компоненттерге зыян келтириши мүмкүн.

Проблемаларды чечүү

КөйгөйМүмкүн себепЧечим
Тартуу станциясы сигнализацияны иштетпейт.Loose wiring, faulty pull station, control panel issue.Check wiring connections. Test with a multimeter if possible. Consult fire alarm technician.
Pull station does not reset with key.Key not fully inserted, internal mechanism jammed, incorrect key.Ensure key is fully inserted and turned correctly. Do not force. Contact technician if issue persists.
Жалган сигналдар.Accidental activation, wiring short, environmental factors.Ensure proper mounting and protection from accidental contact. Inspect wiring for damage. Consult technician.

For issues not listed here, or if troubleshooting steps do not resolve the problem, contact a certified fire alarm technician.

Техникалык шарттар

  • Модел: PSSA
  • Түрү: Single Action Pull Station
  • Калыбына келтирүү ыкмасы: Ачкычты калыбына келтирүү
  • Байланыштары: Бурама терминалдары
  • Жеткиликтүүлүк: Molded operating instructions with Braille text
  • Өлчөмдөрү (пакет): 9 x 6 x 2.5 дюйм (болжол менен)
  • Салмагы (пункт): 9.6 унция (болжол менен)
  • Өндүрүүчү: Silent Knight
  • UPC: 783008104511

Кепилдик жана колдоо

For warranty information and technical support, please contact SILENT KNIGHT directly or refer to the documentation provided with your fire alarm control panel system. It is recommended to have all fire alarm system components installed and serviced by certified professionals.

Көбүрөөк жардам алуу үчүн, расмий SILENT KNIGHT сайтына кириңиз webсайтка же кардарларды тейлөө бөлүмүнө кайрылыңыз.

Тектеш документтер - PSSA

Preview SK-Minimon монитор модулун орнотуу жана техникалык тейлөө боюнча нускамалар | Honeywell компаниясынын Silent Knight
Silent Knight SK-Minimon Addressable Mini-Monitor Module үчүн деталдуу орнотуу жана техникалык тейлөө көрсөтмөлөрү, анын ичинде мүнөздөмөлөрү, орнотуу, зымдар жана шайкештик талаптары.
Preview Silent Knight SK-5208 өрттү көзөмөлдөө/байланыш системасын орнотуу жана эксплуатациялоо боюнча колдонмо
Бул колдонмодо NFPA 72 талаптарына жооп берүү үчүн иштелип чыккан 24 вольттук, 10 зоналуу өрт сигнализациясын башкаруу панели болгон Silent Knight SK-5208 Fire Control/Communicatorду орнотуу, иштетүү жана программалоо боюнча кеңири нускамалар берилген.
Preview SK-2/E жана SK-4/E өрт сигнализациясын башкаруу панелин колдонуу боюнча нускамалар
Silent Knight SK-2/E жана SK-4/E өрт сигнализациясын башкаруу панелин колдонуу боюнча нускамалар, анын ичинде сигнализацияны жана көйгөйлөрдү чечүү, кол менен иштетүү жана сигнализацияны үнсүздөө.
Preview Silent Knight SK-Relay-6 алты релелик башкаруу модулун орнотуу жана техникалык тейлөө боюнча нускамалар
Silent Knight SK-Relay-6 алты реле башкаруу модулун орнотуу жана техникалык тейлөө боюнча колдонмо, анда интеллектуалдык сигнализация системалары үчүн спецификациялар, компоненттердин сүрөттөмөлөрү, орнотуу процедуралары, зымдар схемалары жана системанын шайкештиги жөнүндө кеңири маалымат берилген.
Preview Silent Knight Model 5207 Fire Control/Communicator орнотуу, программалоо жана иштетүү боюнча колдонмо
Silent Knight Model 5207 Fire Control/Communicator үчүн комплекстүү орнотуу, программалоо жана эксплуатациялоо боюнча колдонмо, системанын жөндөөлөрү, агенттиктердин тизмеси, зымдары, иштеши жана көйгөйлөрүн чечүү.
Preview Honeywell Silent Knight Model 5495 бөлүштүрүлгөн кубат модулун орнотуу жана пайдалануу боюнча колдонмо
Бул колдонмо Honeywell Silent Knight Model 5495 бөлүштүрүлгөн кубат модулу үчүн ар тараптуу орнотуу жана эксплуатациялоо боюнча көрсөтмөлөрдү берет, ал 6-amp, 24 вольттук кубаттуулуктагы кеңейткич өрт сигнализация системалары үчүн эскертме түзүлүшүн жана көмөкчү түзүлүштөрдү колдоону жакшыртуу үчүн иштелип чыккан.