1. Киришүү
The Altronix R2416300UL is a rack mount power supply designed to provide 24VAC or 28VAC power for various applications, particularly commercial CCTV equipment. This unit features 16 individually fused outputs, ensuring reliable power distribution and protection. It is housed in a durable steel enclosure and includes a line cord, spare fuse, removable terminal blocks, and mounting brackets for convenient installation.
2. Коопсуздук боюнча маанилүү маалымат
Please read these safety instructions carefully before installing or operating the Altronix R2416300UL power supply. Failure to follow these instructions may result in electric shock, fire, or damage to the unit.
- Электр шок коркунучу: Do not open the unit. Refer all servicing to qualified service personnel.
- Сактагычты алмаштыруу: For continued protection against fire, replace all fuses with the same type and rating (3.5A, 250V).
- Экологиялык шарттар: Do not expose the unit to rain or moisture. Install in a dry, indoor location.
- Вентиляция: Ашыкча ысып кетүүнүн алдын алуу үчүн аппараттын айланасында жетиштүү желдетүүнү камсыз кылыңыз.
- Негиздөө: Ensure the unit is properly grounded according to local electrical codes.
- Кубат булагы: Connect the unit only to a 115VAC, 60Hz power source.

Сүрөт 1: Алдыңкы view of the Altronix R2416300UL Rack Mount Power Supply. This image shows the black steel enclosure with the Altronix logo and 16 green LED indicators for each output. A caution label for electric shock is visible on the right.
3. Орнотуу жана орнотуу
3.1. таңгактан чыгаруу
Carefully remove the power supply from its packaging. Verify that all components are present: the R2416300UL unit, line cord, spare fuse, removable terminal blocks, and mounting brackets.
3.2. Монтаждоо
The R2416300UL is designed for rack mounting. Use the provided mounting brackets to secure the unit into a standard 19-inch equipment rack. Ensure the rack is stable and provides adequate support for the unit's weight (approximately 17.2 pounds).
3.3. Input Power Connection
- Түзмөктүн арткы жагындагы кубат которгучу "OFF" абалында экенин текшериңиз.
- Connect the supplied line cord to the AC input receptacle on the rear of the power supply.
- Plug the other end of the line cord into a grounded 115VAC, 60Hz power outlet.

2-сүрөт: Арткы view of the Altronix R2416300UL Rack Mount Power Supply. This image displays the power switch, AC input, and the array of 16 output terminal blocks. The product label with specifications is also visible.
3.4. Output Connections
The R2416300UL provides 16 individually fused 24VAC or 28VAC outputs. Each output is equipped with a removable terminal block for easy wiring.
- Identify the desired output terminal block (labeled 1 through 16).
- Connect your device's power input wires to the corresponding terminals on the removable block. Ensure correct polarity if applicable to your device.
- Securely insert the wired terminal block into its receptacle on the power supply.
- Repeat for all devices requiring power.

Figure 3: Close-up of the rear product label and output terminal blocks. This image provides a detailed view of the product specifications, safety warnings, and the green removable terminal blocks for connecting output devices.
4. Иштөө нускамалары
4.1. Күйгүзүү / Өчүрүү
- To power on the unit, flip the power switch on the rear panel to the "ON" position.
- To power off the unit, flip the power switch on the rear panel to the "OFF" position.
4.2. Output Indicators
The front panel of the R2416300UL features 16 green LED indicators, one for each output. A lit green LED indicates that the corresponding output is receiving power and the fuse is intact.

Figure 4: Close-up of the front panel showing the 16 green LED indicators. Each LED corresponds to an individual fused output, providing a visual status of power delivery.
5. Техникалык тейлөө
5.1. Жалпы кам көрүү
- Keep the unit clean and free from dust. Use a dry, soft cloth for cleaning.
- Вентиляция тешиктери тоскоол болбогонун текшериңиз.
5.2. Сактагычты алмаштыруу
If an output LED is off, the corresponding fuse may be blown. To replace a fuse:
- Өчүрүү: Disconnect the unit from the main power supply by unplugging the line cord.
- Identify Blown Fuse: Locate the fuse holder for the affected output on the rear panel.
- Remove Fuse: Carefully remove the blown fuse.
- Жаңы сактагычты орнотуу: Replace it with a new fuse of the exact same type and rating: 3.5A, 250V. Using an incorrect fuse can cause damage or fire.
- Күчтү калыбына келтирүү: Reconnect the unit to the main power supply and turn it on. Verify the output LED illuminates.
6. Кыйынчылыктарды
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| No power to the unit (no LEDs lit). |
|
|
| One or more output LEDs are off. |
|
|
| Unit powers on, but connected devices do not function. |
|
|
7. Техникалык шарттар
| Өзгөчөлүк | Деталь |
|---|---|
| Бренд | Altronix |
| Модель номери | R2416300UL |
| Киргизүү көлөмүtage | 115VAC (Minimum 110V, Maximum 115V) |
| Киргизүү жыштыгы | 60 Гц |
| Output Voltage | 24VAC же 28VAC |
| Output Current (24VAC) | 12.5A |
| Output Current (28VAC) | 10A |
| Number of Fused Outputs | 16 |
| Fuse Type/Rating | 3.5А, 250В |
| Форма фактору | Rack Mount |
| Коргоочу материал | Болот |
| Бүтүрүү | Кара |
| Продукциянын өлчөмдөрү (L x W x Y) | 19.13 x 8.5 x 3.27 дюйм |
| Элемент Салмагы | 17.2 фунт |
| Стандарттар | UL 2044 Commercial CCTV, CUL, CE |
| Муздатуу ыкмасы | Аба |
8. Кепилдик жана колдоо
8.1. Кепилдик маалыматы
Altronix products are typically backed by a limited lifetime warranty. For specific warranty terms and conditions applicable to your R2416300UL unit, please refer to the official Altronix webсайтка же түздөн-түз кардарларды тейлөөгө кайрылыңыз. Сатып алганыңыздын далили катары сатып алуу дүмүрчөгүңүздү сактаңыз.
8.2. Техникалык колдоо
For technical assistance, installation questions, or troubleshooting beyond the scope of this manual, please contact Altronix technical support. You can find their contact information on the official Altronix webсайт (www.altronix.com).