This manual provides essential information for the safe and efficient installation, operation, and maintenance of your MAXTRACK Transmedia LT2-2L Halogen Transformer. This electronic converter is designed for halogen lamps with a power range of 35-105W, converting 230V AC input to 12V AC output. It features integrated overload and temperature protection for enhanced safety and reliability. Please read this manual thoroughly before installation and retain it for future reference.
2. Коопсуздук нускамалары
ЭСКЕРТҮҮ: Electrical shock hazard. Installation should only be performed by a qualified electrician in accordance with all local and national electrical codes.
- Always disconnect power at the main circuit breaker before installing or servicing the transformer.
- Ensure the transformer's input voltage (230V) matches your mains supply.
- Do not exceed the maximum load of 105W. The minimum load is 35W.
- This transformer is non-dimmable. Do not connect it to dimmer switches.
- Ensure adequate ventilation around the transformer to prevent overheating.
- Do not expose the transformer to moisture or extreme temperatures.
- The transformer is equipped with overload and temperature protection. If these protections activate, disconnect power, allow the unit to cool, and check for faults in the circuit.
- The device is marked with the CE symbol, indicating conformity with European safety standards.
- The 'MM' symbol indicates suitability for mounting on normally flammable surfaces.

Image: The CE mark, indicating compliance with European safety standards, alongside the input voltage (230V) and output voltage (12V), and the power range (35-105W) of the transformer.

Image: The 'MM' symbol, indicating that the transformer is suitable for mounting on normally flammable surfaces.
3. Продукт бүтүп калдыview
The MAXTRACK Transmedia LT2-2L is a compact electronic halogen transformer designed for reliable power conversion in lighting applications. Its slim profile (130 x 43 x 20 mm) allows for installation in confined spaces.

Сүрөт: Жогорку view of the MAXTRACK Transmedia LT2-2L Halogen Transformer, showing its compact design and labeling with specifications and safety symbols.
Негизги өзгөчөлүктөрү:
- Input: 230V AC, 50/60Hz
- Output: 12V AC
- Кубат диапазону: 35-105W
- Ашыкча жүктөн коргоо
- Температураны коргоо
- Dimmable
- Compact Dimensions: 130 x 43 x 20 mm
4. Техникалык шарттар
| Өзгөчөлүк | Деталь |
|---|---|
| Модель номери | LT2-2L |
| Киргизүү көлөмүtage | 230V AC |
| Output Voltage | 12V AC |
| Power колому | 35-105W |
| Жыштык | 50/60 Гц |
| Коргоо | Overload, Temperature |
| Dimmable | Жок |
| Өлчөмдөрү (L x W x Y) | 130 x 43 x 20 мм |
| Салмагы | 90 г |
| Өндүрүүчү | Transmedia |
| Бренд | MAXTRACK |
5. Орнотуу жана орнотуу
Маанилүү: Installation must be carried out by a qualified electrician. Ensure power is disconnected before proceeding.
- Электр энергиясын өчүрүү: Turn off the main power supply at the circuit breaker to the area where the transformer will be installed. Verify that power is off using a voltage сыноочу.
- Монтаждоо: Select a suitable location for the transformer that allows for adequate ventilation and is protected from moisture. Secure the transformer using appropriate fasteners through the mounting holes.
- Input Wiring (230V AC):
- Connect the live (L) wire from the mains supply to the input terminal marked 'L' on the transformer.
- Connect the neutral (N) wire from the mains supply to the input terminal marked 'N' on the transformer.
- Бардык байланыштар коопсуз жана туура изоляцияланганын текшериңиз.
- Output Wiring (12V AC):
- Connect the 12V halogen lamp(s) to the output terminals marked '12V' on the transformer.
- жалпы ват камсыз кылууtage of the connected lamps is within the transformer's operating range (35-105W).
- Maintain correct polarity if specified by the lamp manufacturer, although for AC halogen lamps, polarity is generally not critical.
- Акыркы текшерүү: Double-check all wiring connections for security and correctness. Ensure no bare wires are exposed.
- Электр энергиясын калыбына келтирүү: Restore power at the main circuit breaker. Test the lighting system.
6. Иштөө нускамалары
Once properly installed, the MAXTRACK Transmedia LT2-2L Halogen Transformer operates automatically when power is supplied. It converts the 230V AC input to 12V AC for your halogen lamps.
- Күйгүзүү/өчүрүү: Control the lighting system using the standard wall switch connected to the transformer's input.
- Өңүлбөс: This transformer is designed for non-dimmable operation. Do not attempt to use it with dimmer switches, as this may damage the unit or the connected lamps.
- Коргоо өзгөчөлүктөрү: The transformer includes built-in overload and temperature protection. In case of an overload or excessive temperature, the unit will temporarily shut down to prevent damage. Disconnect power, allow the unit to cool, and investigate the cause before restoring power.
7. Техникалык тейлөө
The MAXTRACK Transmedia LT2-2L Halogen Transformer requires minimal maintenance.
- Тазалоо: Ensure power is disconnected. Gently wipe the exterior of the transformer with a dry, soft cloth. Do not use liquid cleaners or solvents.
- Текшерүү: Periodically inspect the wiring for any signs of damage, fraying, or loose connections. Address any issues promptly.
- Вентиляция: Ensure that the area around the transformer remains clear of obstructions to allow for proper airflow and heat dissipation.
8. Кыйынчылыктарды
If you encounter issues with your transformer, refer to the following troubleshooting guide:
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Lampс күйбөйт. |
|
|
| Lamps flicker or are dim. |
|
|
| Transformer is hot to the touch. |
|
|
Эгерде бул чечимдерди колдонуп көргөндөн кийин да көйгөй чечилбесе, квалификациялуу электрикке кайрылыңыз.
9. Кепилдик жана колдоо
For warranty information or technical support regarding your MAXTRACK Transmedia LT2-2L Halogen Transformer, please refer to the retailer or the manufacturer's official webсайт. Сатып алганыңыздын далили катары сатып алуу дүмүрчөгүңүздү сактаңыз.