Introduction
The Notifier FRM-1 is an intelligent addressable relay module designed for use in fire alarm systems. This module provides a single Form-C relay contact that can be programmed to operate in response to specific system events. It is an essential component for controlling external devices such as door holders, fans, or other auxiliary equipment within a fire detection and alarm system.
This manual provides detailed instructions for the proper installation, operation, and maintenance of the FRM-1 module to ensure its reliable performance and compliance with safety standards.
Продукт бүттүview

Сүрөт 1: Алдыңкы view of the FRM-1 module, showing the Notifier logo and the status indicator LED.

2-сүрөт: Арткы view of the FRM-1 module, displaying the product label with model number, patent details, and terminal assignments for wiring.

3-сүрөт: Ички view of the FRM-1 module, revealing the screw terminals for loop and address connections, and the mounting plate.

Figure 4: The FRM-1 module with its original packaging and a small installation guide.
The FRM-1 module is compact and designed for easy integration into existing fire alarm control panels (FACP) that support Notifier's intelligent addressable protocol. It features an intelligent design for reliable communication and operation within the system.
Коопсуздук маалыматы
Always observe the following safety precautions when installing, operating, or maintaining the FRM-1 module:
- Орнотуу бардык жергиликтүү жана улуттук электр эрежелерине жана стандарттарына ылайык квалификациялуу адистер тарабынан аткарылышы керек.
- Модулду орнотуудан же тейлөөдөн мурун, өрт сигнализациясын башкаруу панелиндеги бардык электр кубатын ажыратыңыз.
- Электр шоктун алдын алуу үчүн туура жерге туташтырууну камсыз кылыңыз.
- Do not operate the module outside its specified voltage жана учурдагы рейтингдер.
- Refer to the fire alarm control panel manual for specific wiring and programming instructions.
Орнотуу жана орнотуу
The FRM-1 module is designed for DIN rail mounting. Follow these general steps for installation:
- Электр энергиясын өчүрүү: Ensure the fire alarm control panel (FACP) is completely powered down before beginning installation.
- Монтаждоо: Secure the FRM-1 module to a standard DIN rail within the FACP enclosure or an approved auxiliary enclosure.
- Дарек: Set the unique address for the module using the rotary switches on the device. Each module on the Signaling Line Circuit (SLC) must have a distinct address.
- Зымдар: Connect the SLC wiring to the designated terminals (SLC+ and SLC-) on the module. Refer to Figure 2 for terminal assignments.
- Релелик байланыштар: Wire the external device (e.g., door holder, fan control) to the Form-C relay contacts (Normally Open, Normally Closed, Common) as required by your application. Ensure all connections are secure.
- Текшерүү: Бардык зымдардын туташууларынын тууралыгын жана коопсуздугун эки жолу текшериңиз.
- Электр энергиясын калыбына келтирүү: Restore power to the FACP and verify the module's status indicator.
- Системалык программалоо: Program the FACP to recognize the new module and configure its relay operation according to the system's design specifications.
Note: Always consult the specific installation manual for your fire alarm control panel for detailed wiring diagrams and compatibility information.
Иштөө нускамалары
The Notifier FRM-1 operates automatically once properly installed and programmed within the fire alarm system. Its operation is dictated by the programming configured in the main fire alarm control panel (FACP).
- Статус көрсөткүчү: The module features a green LED indicator. This LED typically flashes during normal communication with the FACP and illuminates steadily when the relay is activated or in an alarm/active state, depending on programming.
- Relay Activation: The Form-C relay will change state (from Normally Open to Closed, or Normally Closed to Open) when the FACP sends a command to activate the module, usually in response to an alarm condition or a programmed event.
- Көзөмөл: The FRM-1 module is supervised by the FACP, meaning the panel continuously monitors its presence and operational status. Any communication loss or fault with the module will be reported by the FACP.
For specific operational scenarios and programming details, refer to the programming manual of your Notifier fire alarm control panel.
Техникалык тейлөө
The Notifier FRM-1 module requires minimal maintenance. Regular system checks, as part of the overall fire alarm system maintenance, are crucial to ensure its continued reliability.
- Визуалдык текшерүү: Periodically inspect the module for any signs of physical damage, loose connections, or environmental issues (e.g., excessive dust, moisture).
- Функционалдык тестирлөө: As part of routine fire alarm system testing (e.g., annual or semi-annual), verify the proper operation of the FRM-1 module and the external device it controls. This typically involves initiating a test condition that triggers the relay.
- Тазалоо: If necessary, gently clean the exterior of the module with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is disconnected before cleaning.
All maintenance and testing should be conducted by certified fire alarm technicians in accordance with NFPA 72 and local authority having jurisdiction (AHJ) requirements.
Проблемаларды чечүү
Most issues related to the FRM-1 module will be indicated by the fire alarm control panel (FACP) as a trouble condition. Common troubleshooting steps include:
- Module Trouble/Fault:
- Verify the module's address is correctly set and unique.
- Check SLC wiring connections for looseness, shorts, or opens.
- Ensure the module is receiving proper power from the SLC.
- Consult the FACP's troubleshooting guide for specific trouble codes related to addressable modules.
- Реле иштетилбейт:
- Verify the FACP programming for the module's activation logic.
- Check the wiring to the external device connected to the relay contacts.
- Ensure the external device itself is functional.
- LED көрсөткүч маселелери:
- If the LED is off, check power and SLC communication.
- If the LED is solid when it should be flashing, it may indicate an active state or a fault, depending on the FACP's programming and the module's status.
For complex issues, contact a qualified fire alarm technician or Notifier technical support.
Техникалык шарттар
| Атрибут | Деталь |
|---|---|
| Модель номери | FRM-1 |
| Бренд | Кабарлоочу |
| Продукциянын өлчөмдөрү | 4.9 x 4.9 x 1.3 дюйм |
| Элемент Салмагы | 1.6 унция |
| Монтаж түрү | DIN темир жол |
| Туташтыргыч түрү | Бурама терминалдары |
| Байланыш түрү | Form-C (Normally Open/Normally Closed) |
| Байланыш материалы | Silver |
| Иштөө режими | Автоматтык |
| Power Source | Wired Electric (from SLC) |
| UPC | 783863011252 |
| Биринчи жеткиликтүү күн | 5-декабрь, 2010-жыл |
Кепилдик маалымат
Specific warranty details for the Notifier FRM-1 module are typically provided with the product packaging or can be obtained directly from Notifier or your authorized distributor. Please retain your proof of purchase for warranty claims.
Колдоо жана Байланыш
For technical assistance, product support, or service inquiries regarding the Notifier FRM-1 Intelligent Addressable Relay Module, please contact your authorized Notifier distributor or Notifier technical support. Contact information can typically be found on the Notifier official website or in the documentation provided with your fire alarm control panel.
It is recommended that all installation, programming, and servicing be performed by qualified and certified fire alarm professionals.