Star Y9529 / 52-1071

Star Y9529 Safety Pilot Valve User Manual

Model: Y9529 / 52-1071

1. Киришүү

This user manual provides essential information for the safe installation, operation, and maintenance of the Star Y9529 Safety Pilot Valve. This valve is designed for use with natural gas (NAT) or liquid propane (LP) systems, featuring a 3/8" FPT connection and manual pilot safety. It is rated for 140,000 BTU with a 1/4" CCT pilot out and includes pilot flame adjustment. Please read this manual thoroughly before installation or use.

2. Коопсуздук маалыматы

ЭСКЕРТҮҮ: Туура эмес орнотуу, тууралоо, өзгөртүү, тейлөө же тейлөө мүлккө зыян келтириши, жаракат алуу же өлүмгө алып келиши мүмкүн. Бул жабдууну орнотуудан же тейлөөдөн мурун орнотуу, иштетүү жана тейлөө нускамаларын кылдат окуп чыгыңыз.

3. Продукттун сүрөттөлүшү жана өзгөчөлүктөрү

The Star Y9529 Safety Pilot Valve is a critical component for gas-fired appliances, ensuring safe operation by controlling the gas flow to the pilot and main burner. Its robust design and precise engineering make it suitable for various commercial cooking equipment.

Star Y9529 Safety Pilot Valve

Figure 3.1: Star Y9529 Safety Pilot Valve. This image shows the compact design of the valve with its various connection points for gas lines.

Diagram of a Safety Pilot Valve

Figure 3.2: Schematic diagram of a typical safety pilot valve. This diagram illustrates the internal components and flow paths, including the inlet, outlet, and pilot gas connections.

Негизги өзгөчөлүктөрү:

4. Орнотуу жана орнотуу

Installation of the Star Y9529 Safety Pilot Valve should only be performed by a qualified and licensed professional, such as a gas technician or plumber, in accordance with all local codes and regulations.

Орнотуу кадамдары (Жалпы көрсөтмөлөр):

  1. Turn off Gas Supply: Locate the main gas shut-off valve for the appliance or building and turn it to the "OFF" position.
  2. Аянты желдетүү: Жумуш аймагы жакшы желдетилип турушун камсыз кылыңыз.
  3. Disconnect Old Valve (if applicable): Carefully disconnect the existing pilot valve, noting the connections for the main gas line, pilot gas line, and thermocouple/thermopile.
  4. Байланыштарды даярдоо: Apply appropriate pipe thread sealant (suitable for gas) to the male threads of the gas lines that will connect to the new valve.
  5. Connect New Valve:
    • Connect the main gas supply line to the 3/8" FPT inlet of the Y9529 valve.
    • Connect the pilot gas line to the 1/4" CCT pilot out connection.
    • Connect the thermocouple or thermopile to the designated port on the valve. Ensure connections are snug but do not overtighten.
  6. Коопсуз клапан: Mount or secure the valve in its intended position within the appliance.
  7. Агышууларды текшерүү: After all connections are made, slowly turn on the main gas supply. Apply a soap and water solution to all new connections. Bubbles indicate a gas leak. If leaks are detected, turn off the gas, tighten connections, and re-test. Repeat until no leaks are present.
  8. Сыноо операциясы: Follow the appliance's specific instructions for lighting the pilot and main burner to ensure proper operation of the new valve.

5. Иштөө нускамалары

The Star Y9529 is a manual pilot safety valve. Its operation is integrated with the appliance it serves. Always refer to the specific operating instructions of your appliance for detailed lighting procedures.

General Pilot Lighting Procedure (Consult Appliance Manual for specifics):

  1. Ensure the appliance's main gas valve is in the "OFF" position.
  2. Locate the pilot light assembly.
  3. Press and hold the pilot button or knob on the gas control valve (often part of the pilot valve assembly). This allows gas to flow to the pilot.
  4. While holding the button, use a long lighter or match to ignite the pilot flame.
  5. Continue holding the pilot button for 30-60 seconds after ignition. This allows the thermocouple/thermopile to heat up and generate enough voltage to hold the pilot valve open.
  6. Release the pilot button. The pilot flame should remain lit. If it extinguishes, repeat the process.
  7. Once the pilot is stable, turn the main gas valve knob to the "ON" position to allow gas flow to the main burner.

Пилоттук жалынды тууралоо:

The Y9529 valve includes a pilot flame adjustment screw. This screw allows for fine-tuning the pilot flame size. A proper pilot flame should be blue, steady, and envelop the tip of the thermocouple/thermopile. Adjust clockwise to decrease flame, counter-clockwise to increase. Do not adjust to an excessively large or small flame.

6. Техникалык тейлөө

Regular maintenance ensures the longevity and safe operation of your Star Y9529 Safety Pilot Valve. All maintenance should be performed by a qualified service technician.

7. Кыйынчылыктарды

Before attempting any troubleshooting, ensure the gas supply is on and that you have followed the lighting instructions correctly. If you are unsure or uncomfortable performing these checks, contact a qualified service technician.

КөйгөйМүмкүн себепЧечим
Учкуч күйбөйт.No gas supply; clogged pilot orifice; faulty thermocouple/thermopile; air in gas line.Ensure gas supply is on. Clean pilot orifice (professional). Replace thermocouple/thermopile. Purge air from line (professional).
Pilot lights but goes out when button is released.Thermocouple/thermopile not heating sufficiently; faulty thermocouple/thermopile; pilot flame too small or misdirected.Hold pilot button longer. Check thermocouple/thermopile position in flame. Adjust pilot flame. Replace thermocouple/thermopile.
Main burner does not light after pilot is lit.Main gas valve not open; faulty gas control valve; obstruction in main burner.Ensure main gas valve is "ON". Contact professional for valve or burner inspection.
Газдын жыты.Газдын агып кетиши.Immediately turn off gas supply. Open windows and doors. Do not operate electrical switches. Contact gas company or qualified technician.

8. Техникалык шарттар

СпецификацияНарк
Модель номериY9529 / 52-1071
БрендStar (Mfg: Baso, Mfg# H19AL-2)
Газ түрүнүн шайкештигиЖаратылыш газы (ЖГГ) / Суюк пропан (ЖПГ)
Main Gas Connection3/8" FPT (Female Pipe Thread)
Pilot Gas Connection1/4" CCT (Copper Capillary Tube) Pilot Out
BTU рейтинги140,000 BTU
ӨзгөчөлүктөрүManual Pilot Safety, Pilot Flame Adjustment
Элемент Салмагы1.23 фунт
Өлчөмдөрү (болжолдуу)Width 2-1/2"
Биринчи жеткиликтүү күн1-октябрь, 2016-жыл

9. Кепилдик жана колдоо

Specific warranty information for the Star Y9529 Safety Pilot Valve should be obtained directly from the manufacturer, Star Manufacturing, or the authorized seller from whom the product was purchased. Warranty terms typically cover defects in materials and workmanship for a specified period.

For technical support, service, or to inquire about replacement parts, please contact your equipment supplier or a qualified service technician specializing in commercial gas appliances. Always provide the model number (Y9529 or 52-1071) and any relevant serial numbers when seeking support.