1. Киришүү
This manual provides essential information for the safe installation, operation, and maintenance of your Marley M602W Qmark Electric Line Voltage Wall Thermostat. This device is designed for wall-mounted, heating-only applications and features double-pole operation with a distinct OFF position. Please read these instructions thoroughly before installation and use.
Негизги өзгөчөлүктөрү:
- Double-pole operation with a marked OFF position for enhanced safety.
- Snap action design for extended operational life.
- Temperature differential of 4 degrees Fahrenheit.
- Жөнгө салынуучу температура диапазону 45°Fден 75°Fге чейин.
2. Коопсуздук боюнча маанилүү маалымат
WARNING: Risk of electric shock. Installation must be performed by a qualified electrician in accordance with all local and national electrical codes. Disconnect power at the main service panel before installing or servicing this thermostat.
- Ensure the power supply matches the thermostat's voltage рейтинг (277 вольт).
- Do not operate the thermostat with damaged wiring.
- Термостатты суудан жана ашыкча нымдуулуктан алыс кармаңыз.
- This thermostat is intended for heating control only.
3. Орнотуу (Орнотуу)
The Marley M602W thermostat is designed for wall mounting and direct wiring into a line voltage heating system. Proper installation is crucial for safe and effective operation.
Орнотуу кадамдары:
- Электр энергиясын өчүрүү: Turn off power to the heating circuit at the main electrical panel before beginning installation. Verify power is off using a voltage сыноочу.
- Монтаждоо жери: Select an indoor wall location away from drafts, direct sunlight, and heat sources that could affect temperature readings. Mount at standard switch height.
- Зымдар: Connect the thermostat's wires to your heating system's line voltage wiring. This is a double-pole thermostat, meaning it disconnects both sides of the 277V line when in the 'OFF' position. Ensure all connections are secure and comply with local electrical codes. Refer to the wiring diagram provided with the product packaging for specific connections (L1, L2, T1, T2).
- Коопсуз Термостат: Mount the thermostat securely to the wall box using the provided screws.
- Күчтү калыбына келтирүү: Once installation is complete and all connections are verified, restore power at the main electrical panel.

4. Иштөө нускамалары
The Marley M602W thermostat features a simple manual control for setting your desired room temperature.
Температураны жөндөө:
- Күйгүзүү: Rotate the central dial clockwise from the 'OFF' position to your desired temperature setting. The thermostat will activate the heating system when the room temperature falls 4°F below the set point.
- Температураны коюу: The dial is marked with temperature indicators from 45°F to 75°F. Rotate the dial to align with your preferred temperature.
- Өчүрүү: To completely turn off the heating system, rotate the dial counter-clockwise until it clicks into the 'OFF' position. This engages the double-pole disconnect feature.
5. Техникалык тейлөө
The Marley M602W thermostat requires minimal maintenance to ensure continued reliable operation.
- Тазалоо: Мезгил-мезгили менен термостаттын сыртын жумшак, гamp кездеме. Абразивдүү тазалоочу каражаттарды же эриткичтерди колдонбоңуз. Термостаттын корпусуна суюктук кирбегенин текшериңиз.
- Батареялар жок: This thermostat is corded electric and does not require batteries.
- Текшерүү: Annually inspect the thermostat for any visible damage or loose connections. If any issues are found, disconnect power and consult a qualified electrician.
6. Кыйынчылыктарды
If you experience issues with your Marley M602W thermostat, refer to the following common problems and solutions:
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Thermostat does not turn on/heating system is not active. | No power to the thermostat; thermostat set to 'OFF'; faulty wiring connection; tripped circuit breaker. | Check circuit breaker; ensure thermostat is not in 'OFF' position; verify power supply. If issues persist, consult a qualified electrician to check wiring. |
| Inaccurate temperature control or inconsistent heating. | Thermostat location affected by drafts or heat sources; internal component issue. | Ensure thermostat is not in a drafty area or near a heat source. If the issue continues, the thermostat may require replacement. |
| Knob feels loose or difficult to turn. | Mechanical wear or damage. | If the knob is loose or not functioning correctly, the thermostat may need to be replaced. |
| Thermostat does not work with 240V system. | Туура эмес томtage application or incompatible system. | This thermostat is rated for 277 Volts. Ensure your heating system's voltage matches this specification. Consult a qualified electrician for compatibility verification. |
7. Техникалык шарттар
| Өзгөчөлүк | Деталь |
|---|---|
| Бренд | Марли |
| Модель аты | M602W |
| Controller Type | Push Button (Rotary Dial) |
| Өзгөчө өзгөчөлүк | Temperature Display (via dial markings) |
| Түс | Ак |
| Өзгөчө колдонуулар | Commercial/Industrial Use, Hospital Settings, Home Healthcare |
| Температураны көзөмөлдөө түрү | Manual |
| Байланыш технологиясы | Зымдуу |
| Камтылган компоненттер | Wall Thermostat & Controls |
| Power Source | Электр зымдары |
| Тtage | 277 вольт |
| Материал | Пластик, дат баспас болоттон жасалган |
| Дисплей түрү | Analog (dial markings) |
| Аяктоо түрү | Жылтырак |
| Башкаруу ыкмасы | Rotary Dial |
| Монтаж түрү | Дубалга орнотуу |
| Температура диапазону | 45°F - 75°F |
| Дифференциалдык | 4°F |
| Элемент Салмагы | 8 унция (0.5 фунт) |
| Продукциянын өлчөмдөрү | 2.25 x 2.56 x 4.63 дюйм |
| Сертификаттар | CSA, UL |
| UPC | 098319841513 |
8. Кепилдик жана колдоо
For warranty information and customer support regarding your Marley M602W thermostat, please consult the documentation included with your purchase or visit the official Marley website. You may also contact Marley customer service directly for assistance.
Marley Official Store: Visit the Marley Store on Amazon