Introduction
This manual provides essential information for the installation, operation, and maintenance of the Goodman B1370145 Furnace Burner Roll-Out Limit Switch. This component is a genuine Original Equipment Manufacturer (OEM) part designed for compatibility with Goodman and Amana HVAC systems. Please read these instructions carefully before proceeding with any installation or service.
Коопсуздук эскертүүсү:
Installation and servicing of HVAC components should only be performed by qualified and experienced technicians. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Always disconnect power to the furnace before performing any work. Follow all local codes and regulations.
Продукт бүттүview
The Goodman B1370145 is a normally open, copper-contact limit switch designed to monitor temperatures within a furnace. Its primary function is to act as a safety device, tripping and shutting down the furnace if temperatures exceed a safe operating limit, typically due to a burner flame roll-out condition. This helps prevent potential hazards and damage to the equipment.

Сүрөт: жакын план view of the Goodman B1370145 Furnace Burner Roll-Out Limit Switch. It is a small, circular metal disc with two mounting holes and two electrical terminals, designed to detect overheating.
Орнотуу жана орнотуу
- Шайкештикти текшерүү: Before installation, ensure that the Goodman B1370145 is the correct replacement part for your specific furnace model. Refer to your furnace's service manual or consult a qualified technician.
- Электр энергиясын өчүрүү: ДАЙЫМА turn off the electrical power to the furnace at the main service panel before attempting any installation or maintenance.
- Бар болгон которгучту табыңыз: Identify the existing roll-out limit switch in your furnace. It is typically located near the burner assembly.
- Зымдарды ажыратыңыз: Carefully disconnect the electrical wires from the old switch. Note the orientation of the wires for correct re-connection.
- Эски которгучту алып салуу: Unscrew or unclip the old limit switch from its mounting bracket.
- Жаңы которгуч орнотуу: Mount the Goodman B1370145 in the same location and orientation as the old switch. The panel mount design facilitates secure installation.
- Зымдарды туташтыруу: Reconnect the electrical wires to the new switch's screw terminals. Ensure connections are secure and tight to ensure reliable conductivity.
- Орнотууну текшерүү: Double-check all connections and ensure the switch is securely mounted.
- Күчтү калыбына келтирүү: Once installation is complete and verified, restore power to the furnace.

Image: A graphic with a stop sign and text emphasizing the importance of checking your model number before purchasing or installing parts to ensure compatibility.
This genuine OEM part ensures a perfect fit and compatibility with Goodman and Amana equipment, featuring durable copper contacts for reliable performance.
Иштөө принциптери
The Goodman B1370145 operates automatically as a safety control. It is a "Normally Open" contact type, meaning that under normal operating conditions, the electrical circuit through the switch is open, allowing the furnace to function. If the temperature at the switch's location exceeds its calibrated limit (indicating a potential burner flame roll-out or other overheating condition), the switch will close, interrupting the furnace's control circuit and shutting down the burner. This automatic operation is crucial for preventing unsafe conditions.
Once tripped, the switch typically requires manual reset or a cool-down period before the furnace can operate again, depending on the specific furnace control board logic. Always investigate the cause of a tripped limit switch before resetting and restarting the furnace.
Техникалык тейлөө
The Goodman B1370145 is a sealed component and does not require routine maintenance itself. However, regular maintenance of your furnace is essential to ensure the proper functioning of all safety devices, including this limit switch.
- Мештин жылдык текшерүүсү: Have your furnace inspected annually by a qualified HVAC technician. They will check for proper burner operation, heat exchanger integrity, and the functionality of all safety controls.
- Тазалык: Ensure the area around the limit switch and burner assembly is free from dust, debris, and obstructions that could affect temperature sensing or airflow.
- Зымдардын бүтүндүгү: Periodically check the wiring connections to the limit switch for any signs of corrosion or looseness.
Проблемаларды чечүү
If your furnace is not operating and you suspect the roll-out limit switch has tripped, consider the following:
- Furnace Not Firing: If the furnace attempts to start but immediately shuts down, or does not start at all, a tripped limit switch could be the cause.
- Которгучту баштапкы абалга келтирүү: Some limit switches are auto-resetting, while others require a manual reset button (if present) or simply cooling down. Consult your furnace manual for specific reset procedures.
- Себебин аныктоо: A tripped roll-out limit switch indicates an underlying problem, such as:
- Blocked flue or exhaust vent.
- Cracked heat exchanger (serious hazard!).
- Dirty or obstructed burners.
- Improper gas pressure.
- Faulty blower motor or restricted airflow.
- Professional Diagnosis Required: Do not repeatedly reset the switch without addressing the root cause. A tripped roll-out limit switch is a critical safety indicator. Contact a qualified HVAC technician immediately to diagnose and repair the underlying issue.
- Туура эмес бөлүгү: Ensure the installed switch is the correct OEM part for your furnace model. An incorrect switch may not function properly or safely.
Техникалык шарттар
| Бренд | Гудман |
| Модель номери | B1370145 |
| Продукциянын өлчөмдөрү (L x W x Y) | 6.2 x 3.1 x 2.9 дюйм |
| Элемент Салмагы | 0.16 унция |
| Байланыш түрү | Адатта ачык |
| Туташтыргыч түрү | Бурама |
| Иштөө режими | Автоматтык |
| Актуатор түрү | Limit Switch |
| Байланыш материалы | Жез |
| Circuit Type | 1-жол |
| Эл аралык коргоо рейтинги | IP00 |
| Өндүрүүчү | Гудман |
| Дата биринчи жеткиликтүү | 6-март, 2017-жыл |
Кепилдик маалымат
Specific warranty details for the Goodman B1370145 Furnace Burner Roll-Out Limit Switch are typically provided by the original seller or Goodman Manufacturing. Please retain your proof of purchase. For detailed warranty terms and conditions, refer to the documentation provided with your purchase or contact Goodman customer support directly.
Колдоо
For technical assistance, installation questions, or troubleshooting beyond the scope of this manual, it is highly recommended to contact a qualified HVAC professional. You may also reach out to Goodman customer support for product-specific inquiries.
- Goodman Manufacturing: Visit the official Goodman webбайланыш маалыматы жана колдоо булактары үчүн сайт.
- Qualified HVAC Technician: For safe and effective service, always consult a certified HVAC technician for furnace repairs and component replacements.