Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the True Drain Tube Heater, Model 801805. This 115 Volt component is designed to prevent ice buildup in drain tubes within commercial refrigeration units, ensuring efficient and reliable performance. Please read this manual thoroughly before installation and use.
Коопсуздук маалыматы
WARNING: Electrical Shock Hazard. Always disconnect power before servicing.
- Always disconnect power to the refrigeration unit before installing or servicing the drain tube heater.
- Орнотуу квалификациялуу техник тарабынан аткарылышы керек.
- Voltage supply matches the heater's specifications (115 Volt).
- Do not expose the heater to direct water spray or submersion.
- Keep all wiring connections secure and insulated to prevent electrical hazards.
- Refer to local electrical codes for proper installation procedures.
Пакеттин мазмуну
- 1 x True Drain Tube Heater (Model 801805, 115 Volt)
Орнотуу нускамалары
The True Drain Tube Heater is designed to be installed within the drain pan or along the drain line of a commercial refrigeration unit to prevent freezing.

Image: True Drain Tube Heater, Model 801805, coiled for display. This image shows the True Drain Tube Heater, Model 801805, a flexible heating element designed to prevent ice formation in refrigeration drain lines. It is depicted in a coiled state, highlighting its compact form.
Керектүү куралдар
- Зымдарды сыйрып алуучулар
- Электр лентасы же жылуулукту кичирейтүүчү түтүк
- Cable ties (zip ties)
- Screwdriver (if accessing panels)
Орнотуу кадамдары
- 1-кадам: Электр кубатын ажыратыңыз. Ensure the refrigeration unit is completely disconnected from its power source before beginning any installation.
- Step 2: Locate Drain Tube. Identify the drain tube or drain pan where ice buildup typically occurs.
- Step 3: Position Heater. Carefully position the drain tube heater along the length of the drain tube or within the drain pan. Ensure good contact for effective heat transfer.
- Step 4: Secure Heater. Use appropriate fasteners or cable ties to secure the heater in place, preventing it from shifting.
- Step 5: Electrical Connection. Connect the heater's wires to the designated power terminals (115 Volt) within the refrigeration unit's electrical compartment. Ensure connections are secure and properly insulated with electrical tape or heat shrink tubing.
- 6-кадам: Орнотууну текшериңиз. Double-check all connections and ensure the heater is securely mounted and not obstructing any moving parts or airflow.
- 7-кадам: Кубатты калыбына келтириңиз. Орнотуу аяктагандан жана текшерилгенден кийин, муздаткыч блокко электр кубатын кайра туташтырыңыз.
Video: SH502 Drain and Door Heater Wire for French Door Refrigerator. This video demonstrates the appearance and handling of a drain and door heater wire, similar in function to the True Drain Tube Heater. It provides a visual reference for the type of component being installed.
Операция
The True Drain Tube Heater operates automatically once installed and connected to power. It is designed to maintain a temperature above freezing within the drain tube, preventing ice blockages. No user intervention is typically required for its operation.
Техникалык тейлөө
- Үзгүлтүксүз текшерүү: Periodically inspect the drain tube heater and its wiring for any signs of wear, damage, or loose connections.
- Тазалык: Ensure the drain tube and surrounding area are kept clean and free of debris that could impede the heater's function or drainage.
- Функционалдык текшерүү: During routine refrigeration unit maintenance, verify that the drain tube remains clear of ice. If ice buildup occurs, inspect the heater for proper operation.
- Кесиптик кызмат: If any issues are detected or if the heater is not functioning correctly, contact a qualified service technician for repair or replacement.
Проблемаларды чечүү
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| Heater not warming | Күч жок Туура эмес зымдар Жылыткычтын бузулушу | Электр камсыздоону текшерүү Зымдарды байланыштарды текшериңиз Жылыткычты алмаштырыңыз |
| Ice buildup persists | Heater improperly positioned Heater insufficient for conditions Жылыткычтын бузулушу | Reposition heater for better contact Consult a technician for higher wattage heater if needed Жылыткычты алмаштырыңыз |
| Visible damage to heater/wires | Физикалык зыян | Disconnect power immediately and replace the heater |
Техникалык шарттар
- Модель номери: 801805
- Тtage: 115 вольт
- Өлчөмдөрү: Approximately 6 L x 4 H x 4 W (inches)
- Салмагы: Болжол менен 0.96 унция
- Келип чыккан өлкө: Мексика
Кепилдик жана колдоо
For warranty information or technical support regarding your True Drain Tube Heater, please contact True Refrigeration directly or refer to their official website. Keep your purchase receipt and model number (801805) handy when contacting support.