3M 3M - 2091 - 12/PACK (24 total)

3M 2091 P100 Particulate Filter User Manual

Model: 3M - 2091 - 12/PACK (24 total)

Бренд: 3M

Introduction

This manual provides essential information for the proper use, installation, and maintenance of the 3M 2091 P100 Particulate Filters. These filters are designed to provide respiratory protection against certain oil and non-oil based particles when used with compatible 3M respirators. Please read this manual thoroughly before use to ensure safety and optimal performance.

Продукт бүттүview

The 3M 2091 P100 Particulate Filter is a highly efficient filter designed to protect against a wide range of particulate contaminants. It features advanced electret media for lightweight, easy breathing comfort.

  • NIOSH-approved P100 particulate filter.
  • Provides protection against both oil and non-oil based particles.
  • Utilizes Advanced Electret Media (AEM) for enhanced breathability and comfort.
  • Bayonet compatibility allows use with many 3M half and full facepiece designs.
Two 3M 2091 P100 Particulate Filters

Figure 1: Two 3M 2091 P100 Particulate Filters, showing their circular shape and pink color.

Close-up of a 3M P100 Particulate Filter with text describing its features

2-сүрөт: Детальдуу view of a 3M P100 Particulate Filter, highlighting its NIOSH approval for particulates and the comfort provided by Advanced Electret Media.

Орнотуу жана орнотуу

Follow these steps to properly install the 3M 2091 P100 Particulate Filters onto your compatible 3M respirator:

  1. Select Compatible Respirator: Ensure you have a compatible 3M 6000 series half mask respirator or other 3M facepiece designs with bayonet connectors.
  2. Inspect Filters: Before each use, visually inspect the filter for any signs of damage, tears, or defects. Do not use damaged filters.
  3. Attach Filters: Align the bayonet fitting on the filter with the corresponding connector on the respirator. Push the filter onto the connector and twist clockwise until it clicks into place. Ensure both filters are securely attached.
  4. Perform Seal Check: After attaching the filters, perform a positive and/or negative pressure user seal check as described in your respirator's instruction manual to ensure a proper face-to-respirator seal.
Diagram showing how to attach 3M filters to a respirator

Figure 3: Illustration demonstrating the bayonet compatibility and proper attachment of 3M 2091 filters to a 3M respirator.

Operating Instructions and Applications

The 3M 2091 P100 Particulate Filters are intended for use in environments containing certain oil and non-oil based particles. Always follow established respiratory protection guidelines and safety procedures for your specific application.

Сунушталган колдонмолор:

  • Protection against many oil and non-oil based particulate contaminants.
  • Welding operations.
  • Brazing processes.
  • Torch cutting.
  • Metal pouring activities.
  • Soldering tasks.
  • Exposure to lead, asbestos, cadmium, arsenic, and MDA.

It is crucial to consult with a safety professional to determine the appropriate respiratory protection for your specific workplace hazards.

Worker wearing a 3M respirator with 2091 P100 filters, illustrating suggested applications

Figure 4: A worker demonstrating the use of a 3M respirator with 2091 P100 filters in an industrial setting, highlighting various suggested applications.

Техникалык тейлөө

The 3M 2091 P100 Particulate Filters are maintenance-free and disposable. They should be replaced according to your company's respiratory protection program or when breathing becomes difficult, or when the filters become damaged, whichever comes first. Do not attempt to clean or reuse filters.

  • Replace filters when they become dirty, damaged, or breathing resistance increases significantly.
  • Store unused filters in their original sealed packaging in a cool, dry place away from contaminants.
  • Dispose of used filters in accordance with local regulations for contaminated waste.

Проблемаларды чечүү

If you experience issues while using the 3M 2091 P100 Particulate Filters, consider the following:

  • Дем алуу кыйынчылыгы: If breathing becomes difficult, the filters may be clogged with particulates. Replace both filters immediately.
  • Начар мөөр: If you detect leakage around the facepiece, re-adjust the respirator and perform another user seal check. Ensure the filters are correctly attached. If the seal cannot be achieved, inspect the respirator for damage or consult a safety professional.
  • Адаттан тыш жыт/даам: While these are particulate filters, if you detect an unusual odor or taste, it may indicate exposure to gases or vapors not protected by these filters. Immediately leave the contaminated area and seek appropriate respiratory protection.

Always prioritize your safety. If you are unsure about the effectiveness of your respiratory protection, leave the contaminated area immediately.

Техникалык шарттар

Бренд3M
Модель аты3M - 2091 - 12/PACK (24 total)
Элемент моделинин номери3M - 2091 - 12/PACK (24 total)
Продукциянын өлчөмдөрү6 x 6 x 10 inches; 10.4 ounces (packaging dimensions)
Чыпка түрүP100 Бөлчөк чыпкасы
NIOSH бекитүүсүОоба
ШайкештикCompatible with 3M 6000 series half mask respirators and other 3M facepiece designs with bayonet connectors.

Маанилүү эскертүүлөр

Юридикалык баш тартуу: The product has an expiration date of 11/2021. Ensure to check the expiration date on the product packaging before use. Do not use expired filters.

This product is intended for occupational use only. It is not intended for use by the general public in non-occupational settings. Misuse of this product may result in sickness or death.

Колдоо

For further assistance or technical support regarding 3M respiratory products, please visit the official 3M website or contact 3M customer service. Always refer to the specific instructions provided with your 3M respirator for complete guidance.

Көбүрөөк маалымат алуу үчүн, сиз иш сапары менен болот Amazon'догу 3M дүкөнү.