1. Киришүү
This manual provides essential information for the safe and effective installation, operation, and maintenance of the ABB B6-30-01-01 Compact 3-Pole Contactor. The B6-30-01-01 is a compact 3-pole contactor featuring one auxiliary contact and screw terminals, designed for reliable performance in applications where space is limited. It is suitable for controlling single or three-phase loads in residential, commercial, and industrial environments.
2. Коопсуздук маалыматы
ЭСКЕРТҮҮ: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working on the contactor or connected equipment.
- Ар дайым жергиликтүү жана улуттук электр эрежелерин жана эрежелерин сактаңыз.
- Бардык жабдууларды туура жерге туташтырууну камсыз кылуу.
- тtage and current ratings of the contactor match the application requirements.
- Do not operate the contactor if it is damaged.
3. Продукт бүтүп калдыview
The ABB B6-30-01-01 mini contactor is engineered for controlling various electrical loads. Key features include:
- Компакт дизайн: Optimized for installations with limited space.
- 3-уюлдук конфигурация: For switching three-phase loads.
- 1 Auxiliary Contact: One normally open (NO) auxiliary contact for control circuit applications.
- Бурама терминалдары: Secure and reliable electrical connections.
- Silent Coil: Тынч иштөөнү камсыздайт.
- Switch Position Indication: Visual indication of the contactor's state.
- Монтаждоо параметрлери: Integrated possibility for DIN rail or wall mounting.

1-сүрөт: ABB B6-30-01-01 Compact Contactor. This image displays the grey and black casing of the contactor, clearly showing the screw terminals labeled 1L1, 3L2, 5L3 (inputs), 2T1, 4T2, 6T3 (outputs), A1, A2 (coil connections), and 13NO, 14NO (auxiliary contact). The ABB logo and a QR code are also visible on the unit.
4. Техникалык шарттар
| Модель номери | B6-30-01-01 (Manufacturer's Part Number: GJL1211001R0011) |
| Бренд | ABB |
| Поляктардын саны | 3 |
| Көмөкчү байланыштар | 1 Адатта ачык (NO) |
| Терминал түрү | Бурама терминалдары |
| Rated Operational Power (AC-3) | 4 кВт чейин |
| Rated Operational Current (AC-1) | 20 А / 690 В. |
| Өлчөмдөрү (болжолдуу) | 2.16 x 2.16 x 1.96 дюйм (54.86 x 54.86 x 49.78 мм) |
| Салмагы (болжол менен) | 4 унция (113 грамм) |
| Монтаждоо | DIN Rail or Wall Mounting |
5. Орнотуу
Before beginning installation, ensure all power to the circuit is disconnected. The B6-30-01-01 contactor can be mounted on a standard DIN rail or directly to a panel using screws.
5.1. Монтаждоо
- DIN темир жол орнотуу: Align the contactor's integrated clips with the DIN rail and press firmly until it clicks into place.
- Дубалга орнотуу: Use appropriate screws and anchors (not supplied) to secure the contactor through the designated mounting holes on the base. Ensure the mounting surface is stable and capable of supporting the contactor's weight and any connected wiring.
5.2. Экологиялык эске алуулар
Install the contactor in a clean, dry environment, free from excessive dust, moisture, corrosive gases, and extreme temperatures. Ensure adequate ventilation to prevent overheating.
6. Электр зымдары
Refer to the wiring diagram provided with your specific application and ensure all connections are secure. Use appropriate wire gauges for the expected current load.
6.1. Power Circuit Connections
- Киргизүү терминалдары: Connect the incoming power lines to terminals 1L1, 3L2, жана 5L3.
- Чыгуу терминалдары: Connect the load to terminals 2T1, 4T2, жана 6T3.
6.2. Control Circuit Connections
- Катушка терминалдары: Башкаруу томун туташтырууtage to terminals A1 жана A2. Ensure the control voltage matches the coil voltage rating of the contactor.
- Көмөкчү байланыш: The normally open (NO) auxiliary contact is connected to terminals 13NO жана 14NO. This contact closes when the main coil is energized.
Tighten all screw terminals to the manufacturer's specified torque to ensure reliable electrical contact and prevent loose connections.
7. Операция
The ABB B6-30-01-01 contactor operates by energizing its coil. When the appropriate control voltage is applied to terminals A1 and A2, the coil creates a magnetic field, pulling the main contacts closed and connecting the power circuit from 1L1/3L2/5L3 to 2T1/4T2/6T3. Simultaneously, the auxiliary contact (13NO-14NO) will close.
- Катушканы кубаттандыруу: Applying the rated control voltage to A1 and A2 will close the main and auxiliary contacts.
- Катушканы энергиясыздандыруу: Башкарууну алып салуу томtage from A1 and A2 will cause the coil to de-energize, opening the main and auxiliary contacts.
- Switch Position Indication: A visual indicator on the contactor provides feedback on the current state of the main contacts (e.g., '0' for open, 'I' for closed, or a similar marking).
8. Техникалык тейлөө
Regular maintenance helps ensure the longevity and reliable operation of the contactor. Always disconnect power before performing any maintenance.
- Визуалдык текшерүү: Periodically inspect the contactor for any signs of damage, discoloration, loose connections, or excessive dust accumulation.
- Тазалоо: Use a dry, soft cloth or compressed air to remove dust and debris from the contactor's exterior. Do not use solvents or abrasive cleaners.
- Терминалдын тыгыздыгы: Check and re-tighten all screw terminals as necessary to prevent overheating due to loose connections.
- Байланыш кийими: While internal contacts are generally not user-serviceable, excessive arcing or contact welding may indicate a need for replacement.
9. Кыйынчылыктарды
Эгерде контактор күтүлгөндөй иштебесе, төмөнкү жалпы маселелерди карап көрүңүз:
- Contactor Does Not Energize:
- Check if the control voltage A1 жана A2 терминалдарында бар.
- Verify the control voltage matches the coil's rated voltage.
- Inspect control circuit wiring for loose connections or breaks.
- Contactor Energizes But Load Does Not Receive Power:
- Ensure main power is supplied to 1L1, 3L2, 5L3.
- Check connections to the load at 2T1, 4T2, 6T3.
- Verify the contactor's switch position indicator shows 'closed'.
- Ашыкча ысып кетүү:
- Бошогон терминалдык байланыштарды текшериңиз.
- Ensure the load current does not exceed the contactor's ratings.
- Verify adequate ventilation around the contactor.
If issues persist after troubleshooting, contact qualified electrical personnel or ABB technical support.
10. Кепилдик маалыматы
Specific warranty terms and conditions for the ABB B6-30-01-01 contactor are provided by ABB at the time of purchase. Please refer to the documentation included with your product or visit the official ABB webтолук кепилдик маалымат алуу үчүн сайт. Кепилдик дооматтар үчүн сатып алганыңыздын далилин сактаңыз.
11. Техникалык колдоо
For technical assistance, product inquiries, or service, please contact ABB customer support. Contact information can typically be found on the official ABB website or through your local ABB distributor.
ABB расмий өкүлү Webсайт: www.abb.com