1. Introduction and Overview
The ICM Controls 304C is an advanced heat pump defrost timer designed for efficient operation. This unit integrates multiple time and temperature defrost functions into a compact, conformally coated, open board package. It serves as a direct replacement for ICP part number 1069364.
This manual provides essential information for the proper installation, operation, and maintenance of your ICM Controls 304C defrost timer.

Figure 1: ICM Controls 304C Heat Pump Defrost Timer circuit board. This image displays the green circuit board with various electronic components including resistors, capacitors, diodes, and a large black Tianbo relay. Key markings visible include "MADE IN THE USA", "PCB717-2A", "TIANBO HJQ-15F-S-Z" for the relay, and "ICP P/N 1069364" at the bottom left.
2. Негизги өзгөчөлүктөрү
- Direct replacement for ICP part number 1069364.
- High-power relay outputs capable of handling 1/2 HP fan or strip heat applications.
- Integrated outdoor fan and reversing valve relays.
- Anti-banger feature: Energizes the reversing valve 10 seconds after the outdoor fan relay to allow for pressure equalization.
- On-board test pins for reduced diagnostic time.
- Sensor input for defrost termination.
- Time and temperature-based defrost termination.
- Fixed 10-minute defrost time.
- Pin-selectable defrost intervals: 30, 60, or 90 minutes.
- Y input tracks compressor run times.
- Integral short cycle protection.
- Cool active reversing valve functionality.
3. Орнотуу жана орнотуу
ЭСКЕРТҮҮ: Installation should only be performed by a qualified technician. Disconnect all power to the unit before installation to prevent electrical shock or equipment damage.
- Электр энергиясын өчүрүү: Ensure the main power supply to the heat pump system is completely disconnected.
- Access Existing Control: Locate and access the existing defrost timer or control board within the heat pump unit.
- Зымдарды ажыратуу: Carefully disconnect all wiring from the old control board, noting the position and function of each wire. It is recommended to label each wire before removal.
- Монтаждоо: Mount the ICM Controls 304C in the same location as the previous board, ensuring it is securely fastened.
- Зымдарды туташтыруу: Connect the wires to the corresponding terminals on the ICM Controls 304C. Refer to the wiring diagram provided with your heat pump system or the ICM Controls 304C for specific connections. The board is designed as a direct replacement for ICP 1069364, simplifying the wiring process.
- Defrost Interval Selection: Set the desired defrost interval (30, 60, or 90 minutes) using the pin selectors on the board.
- Электр энергиясын калыбына келтирүү: Once all connections are secure and verified, restore power to the heat pump system.
For detailed wiring diagrams and specific installation procedures, consult the heat pump manufacturer's service manual or a qualified HVAC technician.
4. Операция
The ICM Controls 304C automatically manages the defrost cycles of a heat pump system to prevent ice buildup on the outdoor coil, ensuring optimal heating performance.
- Defrost Cycle Initiation: The unit initiates a defrost cycle based on accumulated compressor run time (Y input) and temperature conditions, at intervals of 30, 60, or 90 minutes as selected.
- Defrost Termination: Defrost cycles are terminated after a fixed 10-minute duration or when the sensor input detects appropriate temperature conditions, whichever occurs first.
- Anti-Banger Feature: During the transition out of defrost, the reversing valve is energized 10 seconds after the outdoor fan relay. This delay allows system pressures to equalize, reducing noise and stress on components.
- Short Cycle Protection: The integrated short cycle protection prevents rapid cycling of the compressor, extending its lifespan.
- Сыноо Pins: On-board test pins are provided to quickly verify operation and reduce diagnostic time. Consult a professional for proper use of these pins.
5. Техникалык тейлөө
The ICM Controls 304C is designed for reliable, maintenance-free operation. However, periodic inspection of the heat pump system by a qualified technician is recommended to ensure all components, including the defrost timer, are functioning correctly.
- Визуалдык текшерүү: During routine system checks, a technician may visually inspect the board for any signs of damage, corrosion, or loose connections.
- Тазалоо: Ensure the area around the control board is free from dust and debris to prevent overheating or interference.
- Туташуу бүтүндүгү: Verify that all electrical connections to the board are secure.
Do not attempt to repair the circuit board yourself. If a malfunction is suspected, contact a qualified HVAC service professional.
6. Кыйынчылыктарды
If your heat pump system is experiencing issues related to defrosting, consider the following basic troubleshooting steps. For complex issues, always consult a qualified HVAC technician.
| Симптом | Мүмкүн себеп | Акция |
|---|---|---|
| Heat pump not defrosting or icing up excessively. |
|
|
| Heat pump frequently entering defrost cycle. |
|
|
| System not heating or cooling properly. |
|
|
Always ensure power is disconnected before inspecting or working on electrical components.
7. Техникалык шарттар
| Параметр | Деталь |
|---|---|
| Модель номери | ICM304C |
| Өндүрүүчү | ICM башкаруу элементтери |
| Бөлүмдүн номери | Icm304c |
| Direct Replacement For | ICP 1069364 |
| Эритүү убактысы | Fixed 10 minutes |
| Defrost Intervals | Pin selectable: 30, 60, 90 minutes |
| Relay Output Capacity | 1/2 HP fan or strip heat |
| Материал | Copper (referring to internal components/traces) |
8. Кепилдик жана колдоо
For information regarding product warranty, technical support, or service, please contact ICM Controls directly or visit their official webсайт. Сатып алуу квитанциясын кепилдик дооматтары үчүн сатып алуунун далили катары сактаңыз.
Manufacturer: ICM Controls
Кошумча жардам алуу үчүн, сураныч, карагыла Amazon'догу ICM Controls дүкөнү or the official ICM Controls webсайт.