Welch Allyn WEL7670-02

Welch Allyn 7670-02 767 дубал анероиди, 8 фут спираль түтүкчөлөрү менен колдонуучунун колдонмосу

Introduction

The Welch Allyn 767 Wall Aneroid is a blood pressure monitor designed for accurate and reliable readings in clinical settings. Its improved ergonomics and modern design enhance usability. This manual provides essential information for the proper setup, operation, and maintenance of your device.

Негизги өзгөчөлүктөрү

Продукт бүттүview

Welch Allyn 767 Wall Aneroid blood pressure monitor mounted on a wall, showing the dial, inflation bulb, and coiled tubing.

Figure 1: Welch Allyn 767 Wall Aneroid Blood Pressure Monitor.

This image displays the Welch Allyn 767 Wall Aneroid blood pressure monitor. It features a large, square black dial with white markings for blood pressure readings, housed in a light-colored square casing. Below the dial, a black inflation bulb and a long, black coiled tubing are visible, connecting the unit to a cuff (not shown). The entire unit is designed for wall mounting.

Компоненттери:

Орнотуу нускамалары

  1. Жайгашкан жерди тандоо: Select a suitable wall location, preferably near the examination area, ensuring it is at eye level for easy reading.
  2. Монтаждоо: Securely attach the wall mount bracket to a sturdy wall stud or use appropriate wall anchors. Ensure the bracket is level before tightening screws.
  3. Attach Aneroid: Carefully slide the Welch Allyn 767 Aneroid onto the mounted bracket until it clicks securely into place.
  4. Түтүктү туташтыруу: Connect the coiled tubing from the aneroid to the blood pressure cuff. Ensure all connections are snug to prevent air leaks.
  5. Алгачкы текшерүү: Before first use, perform a quick visual inspection to ensure all components are intact and properly connected.

Иштөө нускамалары

Кан басымын так өлчөө үчүн төмөнкү кадамдарды аткарыңыз:

  1. Пациенттин жайгашуусу: Have the patient sit comfortably with their arm supported at heart level. Ensure they are relaxed and have not exercised or consumed caffeine/nicotine recently.
  2. Манжеттин жайгашуусу: Select the appropriate size blood pressure cuff. Wrap the cuff firmly around the patient's bare upper arm, ensuring the artery marker on the cuff aligns with the brachial artery.
  3. Инфляция: Close the air release valve on the inflation bulb. Rapidly inflate the cuff by squeezing the bulb until the gauge reads approximately 20-30 mmHg above the patient's usual systolic pressure, or until the radial pulse is no longer palpable.
  4. Deflation and Reading: Slowly open the air release valve to deflate the cuff at a rate of 2-3 mmHg per second.
    • Систоликалык басым: Note the reading on the aneroid gauge when you first hear the Korotkoff sounds (a tapping sound).
    • Диастоликалык басым: Note the reading when the Korotkoff sounds disappear or become muffled.
  5. Аба чыгаруу: Fully open the air release valve to deflate the cuff completely.
  6. Кайталап өлчөө: If necessary, wait at least 1-2 minutes before taking another reading on the same arm.

Техникалык тейлөө

Proper maintenance ensures the longevity and accuracy of your Welch Allyn 767 Wall Aneroid.

Проблемаларды чечүү

КөйгөйМүмкүн себепЧечим
Туура эмес окууларCuff size incorrect, improper cuff placement, air leak, device needs calibration.Ensure correct cuff size and placement. Check for leaks in tubing/cuff. Schedule professional calibration.
Cuff Does Not InflateAir release valve open, leak in tubing/cuff, faulty inflation bulb.Close valve. Check all connections for leaks. Replace faulty components if necessary.
Gauge Needle Jumps ErraticallyRapid cuff deflation, patient movement, internal gauge issue.Deflate cuff slowly (2-3 mmHg/sec). Ensure patient stillness. Contact service if issue persists.

Техникалык шарттар

Кепилдик жана колдоо

For warranty information, technical support, or service inquiries regarding your Welch Allyn 7670-02 Wall Aneroid, please contact the manufacturer directly.

Өндүрүүчүнүн байланышы:

Always refer to the official Welch Allyn website or documentation for the most current warranty terms and support procedures.

Тектеш документтер - WEL7670-02

Preview Welch Allyn Connex Spot Monitor Upute
Welch Allyn Connex Spot Monitor мониторунун документтерин толуктоо керек.
Preview Welch Allyn HScribe: Uživatelská příručka pro analýzu Holterova monitorování
Tato uživatelská příručka poskytuje podrobné information osystému Welch Allyn HScribe про анализую Holterova monitorování, орнотууларды орнотуу, провозу, údržby a řešení problémů.
Preview Welch Allyn HScribe Holter Analiz Sistemi Kullanıcı Kılavuzu
Welch Allyn HScribe Holter Analiz Sistemi үчүн колдонуу колдонмосу. Tıbbi profesyoneller için kurulum, kullanım, bakım ve sorun giderme bilgileri камтыйт.
Preview Welch Allyn® HScribe™ System анализи holterowskiej Instrukcja Obsługi
Instrukcja obsługi systemu Analysis holterowskiej Welch Allyn HScribe, zawierająca маалымат же орнотуу, конфигурация, обструкция, анализи даныч ЭКГ жана профессионалисттик медиктердин отчеттору. Dokument objejmuje funkcje systemu, bezpieczeństwo użytkowania oraz rozwiązywanie problemów.
Preview Welch Allyn Кан басымы манжеттер жана анероиддер каталогу
Welch Allyn кан басымынын манжеттеринин комплекстүү каталогу, анын ичинде FlexiPort™ көп жолу жана бир жолу колдонулуучу варианттары, EcoCuff™ бир бейтапка колдонуучу манжеттер жана Tycos® 767-Series жана Durashock™ моделдери сыяктуу ар кандай анероиддик сфигмоманометрлер. Кан басымын так өлчөө үчүн өлчөмдөр багыттары, продукттун спецификациялары жана артыкчылыктары бар.
Preview Welch Allyn дубалга орнотулган сфигмоманометр жана интегралдык кубаттагыч колдонуучусунун колдонмосу
Welch Allyn дубалга орнотулган сфигмоманометри, Android планшетинин/компьютеринин кубаттагычы жана анероиддик өлчөгүчү үчүн кеңири колдонуучу колдонмосу. 5000 сериясындагы моделдердин иштешин, мүнөздөмөлөрүн, техникалык тейлөөсүн жана кепилдикти камтыйт.