This document provides essential information for the VULCAN-HART Pilot (Reverse Hood, NAT/LP), part number 109839-3. This pilot assembly is designed for use with natural gas (NAT) or liquid propane (LP) systems in compatible Vulcan-Hart commercial kitchen equipment.

VULCAN-HART Pilot (Reverse Hood, NAT/LP) 109839-3

Image: VULCAN-HART Pilot (Reverse Hood, NAT/LP) 109839-3. This image displays the pilot assembly, which includes a metal bracket, a threaded base with a hexagonal nut, and a pilot hood. A separate, smaller gas orifice component is shown to the left.

Негизги өзгөчөлүктөрү:

  • VULCAN-HART genuine replacement part.
  • Top Pilot Burner Kit.
  • Part Number: 109839-3.
  • Compatible with Natural Gas (NAT) or Liquid Propane (LP) systems.
  • Weight: Approximately 0.069 lb (1.12 ounces).

Техникалык шарттар

Бөлүмдүн номери109839-3
Башка тетиктердин номерлери109839-1, 409839-1, 409839-3
Газ түрүнүн шайкештигиNatural Gas (NAT) or Liquid Propane (LP)
Салмагы0.069 lb (approximately 1.12 ounces)
ӨндүрүүчүВУЛКАН-Харт
Элемент моделинин номери228-1087
UPC222810871919

Compatible Vulcan-Hart Models:

This pilot assembly is compatible with various Vulcan-Hart models, including but not limited to:

  • Ranges/Ovens: SG7830, 7830
  • GHM Series: GHM30, GHM30C, GHM45/72, GHM60, GHM60/45, GHM60/72, GHM60T, GHM60T/45, GHM60T/72, GHM72, GHM72/45
  • GHXM Series: GHXM60, GHXM60T, GHXM72
  • GHX Series: GHX60, GHX60T, GHX72
  • GH Series: GH30, GH30C, GH45/72, GH6T45C, GH60, GH60/45, GH60/72, GH60T, GH60T/45, GH60T/72, GH6045C, GH72, GH72/45

Орнотуу

Installation of this pilot assembly should only be performed by a qualified service technician. Improper installation can lead to gas leaks, fire hazards, or equipment damage. Always ensure the gas supply to the appliance is turned off and disconnected before beginning any installation or maintenance procedures.

  1. Биринчи коопсуздук: Disconnect the appliance from all power sources and turn off the main gas supply valve.
  2. Мүмкүнчүлүк: Carefully access the pilot assembly area within the appliance, following the specific service manual for your Vulcan-Hart model.
  3. Алып салуу: Disconnect the old pilot assembly, noting the connections for gas lines and thermocouple/igniter wires.
  4. Орнотуу: Install the new VULCAN-HART Pilot (Reverse Hood, NAT/LP) 109839-3, ensuring all connections are secure and properly sealed. Verify correct orientation for the reverse hood design.
  5. Агып кетүүнү текшерүү: After installation, turn on the gas supply and perform a thorough leak check using an approved leak detection solution.
  6. Сыноо операциясы: Restore power and test the pilot ignition and burner operation according to the appliance's service manual.

Refer to your specific Vulcan-Hart appliance service manual for detailed, model-specific installation instructions and safety warnings.

Операция

The pilot assembly is an internal component responsible for igniting the main burners of your Vulcan-Hart appliance. Its operation is typically automatic once installed and configured correctly. Users interact with the appliance's main controls (e.g., thermostats, burner knobs) to initiate the ignition sequence.

  • Ensure the appliance's main gas supply is open.
  • Follow the appliance's specific startup procedure, which usually involves turning a control knob to a "Pilot" or "Ignite" position and holding it to allow the pilot to light and heat the thermocouple.
  • Once the pilot is established, turn the control knob to the desired operating temperature or burner setting.

If the pilot fails to light or stay lit, refer to the Troubleshooting section or consult a qualified technician.

Техникалык тейлөө

Regular maintenance of the pilot assembly ensures reliable operation and extends the lifespan of your appliance. Maintenance should be performed by a qualified technician.

  • Жылдык текшерүү: Have the pilot assembly inspected annually for signs of wear, corrosion, or blockage.
  • Тазалоо: Ensure the pilot orifice and hood are free from debris, grease, or carbon buildup. A small wire brush or compressed air may be used carefully.
  • Жалынды текшерүү: Verify that the pilot flame is strong, stable, and properly enveloping the thermocouple (if applicable). The flame should typically be blue with a small yellow tip.
  • Компонентти текшерүү: Inspect gas lines for leaks and electrical connections (for igniters/thermocouples) for security and integrity.

Always disconnect power and gas supply before performing any maintenance.

Проблемаларды чечүү

If you experience issues with your pilot assembly, consider the following common problems. For complex issues, contact a qualified service technician.

КөйгөйМүмкүн себепЧечим
Учкуч күйбөйт.No gas supply; clogged pilot orifice; faulty igniter/thermocouple; incorrect gas pressure.Check gas supply valve; clean pilot orifice; inspect/replace igniter/thermocouple; verify gas pressure (technician).
Pilot lights but will not stay lit.Faulty thermocouple/thermopile; pilot flame not enveloping thermocouple; low gas pressure.Adjust pilot flame; inspect/replace thermocouple/thermopile; verify gas pressure (technician).
Weak or yellow pilot flame.Partially clogged pilot orifice; incorrect air mixture; low gas pressure.Clean pilot orifice; adjust air shutter (if applicable); verify gas pressure (technician).

Эскертүү: Do not attempt to repair gas components if you are not qualified. Contact a certified gas technician for all gas-related issues.

Кепилдик жана колдоо

For warranty information regarding the VULCAN-HART Pilot (Reverse Hood, NAT/LP) 109839-3, please refer to the documentation provided with your original Vulcan-Hart appliance or contact Vulcan-Hart customer support directly. Keep your purchase receipt for warranty claims.

For technical support or to locate authorized service providers, visit the official Vulcan-Hart website or consult your appliance's user manual.

Тектеш документтер - 109839-3

Preview Vulcan 60" газ рестораны диапазону V260-1: Өзгөчөлүктөрү, өзгөчөлүктөрү жана орнотуу
Вулкан 60 дюймдук газ рестораны диапазону (V260-1 модели) үчүн деталдуу спецификациялар, стандарттык өзгөчөлүктөр, орнотуу көрсөтмөлөрү жана боштуктар 6 ачык күйгүзүүчү жана 24 дюймдук бройлер менен коммерциялык ашканалар үчүн иштелип чыккан.
Preview Vulcan V сериясы HDR газ диапазондорун иштетүү боюнча колдонмо
Vulcan V Series HDR газ диапазондору үчүн комплекстүү операциялар, орнотуу, тазалоо жана тейлөө боюнча колдонмо, коопсуздук, орнотуу, колдонуу, бузулууларды аныктоо жана тейлөө маалыматын камтыйт.
Preview Vulcan LG Series Газ Фритерлери: Орнотуу жана Операциялык колдонмо
Vulcan компаниясынын бул комплекстүү колдонмосу LG Сериялуу Газ Фритерлерин (LG300, LG400, LG500 моделдери) орнотуу, иштетүү жана тейлөө боюнча толук нускамаларды камтыйт. Ал коопсуздук эскертүүлөрүн, орнотуу жол-жоболорун, колдонуу боюнча көрсөтмөлөрдү жана коммерциялык ашканалар үчүн көйгөйлөрдү чечүү боюнча кеңештерди камтыйт.
Preview Vulcan GRM Series Gas Fryers: Installation and Operational Manual
Comprehensive installation, operation, maintenance, and troubleshooting guide for Vulcan GRM Series Gas Fryers, covering safety, setup, usage, and warranty information. Includes model details, capacities, and procedures.
Preview Vulcan SG4 & SG6 Series Full Size Gas Convection Ovens Service Manual
Service manual for Vulcan SG4 and SG6 Series Full Size Gas Convection Ovens (SG4D, SG4C, SG6D, SG6C). Includes specifications, component details, removal/replacement guides, and troubleshooting for commercial kitchens.
Preview Vulcan 4-Burner Heavy Duty Gas Range (36-Inch Wide) - V4B36 Series Datasheet
Detailed specifications, features, and installation instructions for the Vulcan 4-burner, 36-inch wide heavy-duty gas range series (V4B36, V4B36B, V4B36S, V4B36C). Includes information on modular, cabinet base, standard oven, and convection oven models for commercial kitchens.