AEM 30-0300

AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge User Manual

1. Киришүү

This manual provides comprehensive instructions for the installation, operation, and maintenance of the AEM 30-0300 X-Series Wideband UEGO Air/Fuel Ratio (AFR) Sensor Controller Gauge. The AEM X-Series Wideband UEGO gauge utilizes advanced X-Digital technology to deliver fast and accurate air/fuel ratio readings, crucial for optimal engine tuning and monitoring.

2. Коопсуздук маалыматы

WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.

Always ensure proper ventilation when working on vehicles. Disconnect the vehicle's battery before performing any electrical work. Incorrect installation or use can lead to vehicle damage or personal injury. If you are unsure about any installation steps, consult a qualified automotive technician.

3. Кутуда эмне бар

The AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge package includes the following components:

Contents of AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge kit

Image 3.1: All components included with the AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge. This includes the gauge, wideband sensor, various wiring harnesses, and mounting accessories.

4. Негизги өзгөчөлүктөрү

The AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge offers several advanced features:

5. Орнотуу жана орнотуу

Proper installation is critical for the accurate and reliable operation of your AEM X-Series Wideband UEGO Gauge. It is recommended that installation be performed by a qualified professional.

5.1 Сенсорду орнотуу

The wideband UEGO sensor must be installed in the exhaust system. For optimal performance, install the sensor at least 18 inches downstream from the exhaust port, before any catalytic converters. Ensure the sensor bung is welded securely and the sensor is oriented to prevent condensation buildup.

5.2 Gauge Mounting

Mount the gauge in a location that is easily visible to the driver and protected from direct moisture and extreme heat. The gauge fits into a standard 52mm (2-1/16 inch) opening.

Side view of AEM 30-0300 gauge showing mounting studs

Сүрөт 5.1: Каптал view of the AEM 30-0300 gauge, illustrating its compact design and the rear mounting studs for secure installation into a dashboard or gauge pod.

5.3 Зымдарды туташтыруу

The gauge requires power, ground, and connections to the wideband sensor. Additionally, there are output wires for data logging and feedback control. Refer to the official AEM user guide PDF for detailed wiring diagrams specific to your application.

AEM 30-0300 wideband sensor and wiring harnesses

Image 5.2: The wideband sensor and associated wiring harnesses. Proper connection of these components is essential for accurate AFR readings and data output.

For detailed wiring diagrams and installation steps, please refer to the official AEM User Guide PDF linked in Section 9.

6. Иштөө нускамалары

Once properly installed and powered, the AEM X-Series Wideband UEGO Gauge will display the current Air/Fuel Ratio (AFR) or Lambda value. The gauge automatically calibrates the sensor upon startup.

6.1 Дисплейди окуу

The large seven-segment display shows the numerical AFR value. The outer LED sweep provides a quick visual reference of the AFR range. The gauge typically displays AFR values from 8:1 (rich) to 20:1 (lean).

Close-up of AEM 30-0300 gauge display showing AFR reading

Сүрөт 6.1: Жакын пландан view of the AEM 30-0300 gauge display, showing a typical AFR reading and the surrounding LED sweep for quick visual interpretation.

6.2 Mode and Select Buttons

The gauge features 'MODE' and 'SEL' (Select) buttons, typically located on the front or side of the unit. These buttons allow you to cycle through display modes (e.g., AFR, Lambda) or perform specific functions as outlined in the detailed user manual.

7. Техникалык тейлөө

The AEM X-Series Wideband UEGO Gauge and sensor are designed for durability, but proper maintenance ensures longevity and accuracy.

8. Кыйынчылыктарды

If you encounter issues with your AEM X-Series Wideband UEGO Gauge, consider the following common troubleshooting steps:

For more detailed troubleshooting guides and error codes, refer to the complete AEM User Guide PDF.

9. Техникалык шарттар

СпецификацияНарк
Модель номери30-0300
Өлчөмдүн түрүWideband UEGO AFR Sensor Controller Gauge
ТехнологияX-Digital
ДисплейDigital 7-segment with LED sweep
Чыгуу сигналдары0-5v Analog, RS232 Serial Port, AEMnet (CANbus)
Өлчөмдүн диаметри52mm (2-1/16 inch)
Элемент Салмагы0.01 ounces (Controller/Gauge only)
ӨндүрүүчүAEM

10. Кепилдик жана колдоо

For warranty information, please refer to the documentation provided with your product or visit the official AEM website. AEM provides technical support for its products. If you require assistance with installation, operation, or troubleshooting beyond the scope of this manual, please contact AEM customer service directly.

11. Кошумча ресурстар

For the most detailed and up-to-date installation instructions, wiring diagrams, and advanced features, please download the official AEM User Guide PDF:

Расмий колдонуучу колдонмосун жүктөп алыңыз (PDF)

Тектеш документтер - 30-0300

Preview Mitsubishi Eclipse, Talon, Laser, Galant VR4 үчүн AEM EMS 30-6300 орнотуу боюнча нускамалар
1990-1994-жылдардагы Mitsubishi Eclipse Turbo, Talon Tsi, Dodge/Eagle Talon Tsi, Mitsubishi Eclipse RS жана Mitsubishi Galant VR4 үчүн иштелип чыккан AEM кыймылдаткычын башкаруу системасын (EMS) P/N 30-6300 орнотуу боюнча кеңири колдонмо. Программалык камсыздоону орнотуу, ECUну алып салуу/орнотуу, калибрлөө, жөндөө, мүчүлүштүктөрдү оңдоо, сенсорду конфигурациялоо, зымдарды жана төөнөгүч схемаларын камтыйт.
Preview 2003-2005-жылдардагы Mitsubishi EVO 8 үчүн AEM 30-3511 Infinity PnP адаптеринин жабдыктарын орнотуу боюнча колдонмо
2003-2005-жылдардагы Mitsubishi EVO 8 моделдери үчүн AEM 30-3511 Infinity Plug and Play адаптеринин жабдыктарын орнотуу боюнча кеңири колдонмо.view, комплекттин мазмуну, параметрлер, колдонмонун маанилүү эскертүүлөрү, орнотуу кадамдары, орнотуу чебери жана пинут маалыматы.
Preview AEM 21-8128DC 2015 Ford F150 EcoBoost үчүн орнотуу нускамалары
2015 Ford F150 EcoBoost 2.7L жана 3.5L Turbo моделдери үчүн AEM 21-8128DC аткаруу аба соргуч системасы үчүн толук орнотуу көрсөтмөсү. Бөлүктөр тизмеси жана кадам-кадам нускамаларды камтыйт.
Preview Chevrolet Malibu 1.5T үчүн AEM 21-813C муздак аба соргуч орнотуу нускамалары
2016-2018 Chevrolet Malibu моделдеринде 1.5T кыймылдаткычы бар AEM 21-813C Dryflow Cold Air Intake системасын орнотуу боюнча толук көрсөтмө. Тетиктердин тизмесин, керектүү шаймандарды жана кепилдик маалыматын камтыйт.
Preview AEM G13116RNS Control Panel Installation and Operation Supplement
This document provides installation and operation details for the AEM G13116RNS One-Line Control Panel, featuring Bluetooth connectivity. It covers product description, regulatory approvals, installation notes, and troubleshooting for aviation audio systems.
Preview AEM 21-8017 Dryflow алуу системасын орнотуу боюнча нускамалар
2004-2005 Chevrolet Silverado жана V8-6.6L DSL кыймылдаткычы бар GMC Sierra үлгүлөрү үчүн AEM 21-8017 Dryflow Intake System үчүн деталдуу орнотуу нускамалары, анын ичинде тетиктердин тизмеси жана кепилдик маалыматы.