Senville GS-380

Senville GS-380 Mini Split Ground Stain колдонуучусунун колдонмосу

Модел: GS-380

1. Продукт бүтүп калдыview

The Senville GS-380 Mini Split Ground Stand is designed to provide stable and elevated support for outdoor mini split air conditioner condenser units ranging from 9000 to 12000 BTU. This heavy-duty stand protects your unit from ground-level elements such as dirt, snow, and grass clippings, contributing to extended equipment life and optimal performance. Its robust construction ensures durability in various outdoor conditions.

Senville GS-380 Mini Split Ground Stand

Figure 1: Senville GS-380 Mini Split Ground Stand, front view.

2. Коопсуздук маалыматы

Please read and understand all safety instructions before assembly and installation. Failure to follow these instructions may result in property damage or injury.

  • Чогултуу учурунда ар дайым кол кап жана коопсуздук көз айнеги сыяктуу тиешелүү жеке коргонуу каражаттарын (ЖКК) кийиңиз.
  • Ensure the installation surface is level and capable of supporting the combined weight of the stand and the air conditioner unit.
  • 300 lbs (136 кг) максималдуу салмак сыйымдуулугунан ашпаңыз.
  • Securely fasten all bolts and nuts during assembly to prevent instability.
  • Балдарды жана үй жаныбарларын орнотуу аянтынан алыс кармаңыз.
  • Орнотуу процессинин кандайдыр бир бөлүгүнө ишенбесеңиз, квалификациялуу адиске кайрылыңыз.

3. Орнотуу жана орнотуу

The Senville GS-380 stand is designed for straightforward assembly. The package includes all necessary installation hardware for the stand itself.

3.1. Пакеттин мазмуну

Монтаждоону баштоодон мурун бардык компоненттердин бар экендигин текшериңиз:

  • Негизги кадр компоненттери
  • Adjustable legs with feet
  • Mounting brackets for AC unit
  • Assorted bolts, nuts, and washers
Close-up of Senville GS-380 stand corner with bolts and hardware

Figure 2: Corner assembly showing included installation hardware.

3.2. Чогултуу кадамдары

  1. Компоненттерди таңгактан чыгаруу: Таңгактан кылдаттык менен бардык бөлүктөрүн чыгарып, таза, тегиз бетке жаткызыңыз.
  2. Негизги кадрды чогултуу: Connect the horizontal frame pieces using the provided bolts, nuts, and washers. Ensure all connections are snug but do not fully tighten yet.
  3. Буттарды бекитүү: Secure the four adjustable legs to the corners of the main frame. The legs are designed to fit into the corner brackets. Use the appropriate bolts and washers for these connections.
  4. Жөнгө салынуучу буттарды орнотуу: Attach the round adjustable feet to the bottom of each leg. These allow for leveling the stand on uneven surfaces.
  5. Mount AC Unit Brackets: Position the adjustable mounting brackets onto the top horizontal bars of the stand. These brackets are designed to align with the mounting holes on your mini split condenser unit. Adjust their width as needed to match your unit's specifications.
  6. Акыркы бекемдөө: Once all components are assembled and positioned correctly, fully tighten all bolts and nuts. Ensure the stand is rigid and stable.
Close-up of adjustable top bracket on Senville GS-380 stand

Figure 3: Adjustable top brackets for securing the AC unit.

3.3. Жайгаштыруу жана тегиздөө

  • Choose a stable, level surface for the stand, such as a concrete pad, patio, or rooftop.
  • Use a spirit level to ensure the stand is perfectly level. Adjust the feet as necessary.
  • Place your 9000-12000 BTU mini split condenser unit onto the stand, aligning its mounting holes with the adjustable brackets.
  • Secure the AC unit to the stand using appropriate bolts (not included with the stand, typically supplied with the AC unit or purchased separately).
Senville GS-380 stand supporting a mini split AC unit, illustrating 300 lbs capacity

Figure 4: The stand supporting a mini split AC unit, demonstrating its heavy-duty capacity.

4. Function and Benefits

The Senville GS-380 Ground Stand serves to elevate your mini split outdoor unit, providing several key benefits:

  • Элементтерден коргоо: Lifts the unit above ground, protecting it from accumulated snow, standing water, dirt, and debris.
  • Жакшыртылган аба агымы: Ensures unobstructed airflow around the condenser unit, which is crucial for efficient operation.
  • Вибрацияны азайтуу: Helps to minimize vibrations transmitted to the ground or building structure.
  • Pest Deterrence: Reduces the likelihood of pests and rodents nesting within or around the unit.
  • Узартылган өмүр мөөнөтү: By mitigating exposure to harsh ground conditions, the stand contributes to the longevity of your AC unit.
Senville GS-380 stand highlighting features: Weather Resistant, UV Coated, Durable Materials, Outdoor Use

Figure 5: Key features of the Senville GS-380 Ground Stand.

5. Техникалык тейлөө

Regular maintenance of your Senville GS-380 Ground Stand will ensure its continued stability and appearance.

  • Мезгилдүү текшерүү: Annually inspect all bolts and nuts for tightness. Re-tighten if any have loosened due to vibration or weather changes.
  • Тазалоо: Clean the stand periodically with a damp Кирди, чаңды жана таштандыларды кетирүү үчүн чүпүрөк колдонуңуз. Каптамага зыян келтириши мүмкүн болгон абразивдүү тазалоочу каражаттардан алыс болуңуз.
  • Даттын алдын алуу: While the stand is weather-resistant, inspect for any signs of rust, especially on hardware. If rust appears, clean the area and apply a rust-inhibiting paint or coating. Consider replacing standard hardware with galvanized or stainless steel alternatives for enhanced corrosion resistance, particularly in humid or coastal environments.
  • Деңгээлди текшерүү: Verify that the stand remains level, especially after significant weather events or ground shifts. Adjust the feet as needed.

6. Кыйынчылыктарды

6.1. Stand Instability

  • Маселе: The stand wobbles or is not level.
  • Чечим: Ensure all bolts are fully tightened. Adjust the individual feet on each leg to achieve a stable and level position. Verify the ground surface is firm and even.

6.2. Missing or Incorrect Hardware

  • Маселе: Some bolts, nuts, or washers are missing or do not seem to fit.
  • Чечим: Double-check the package contents against the parts list. If hardware is genuinely missing or incorrect, contact Senville customer support for assistance. Note that bolts for securing the AC unit to the stand are typically not included with the stand.

6.3. Rust Formation

  • Маселе: Rust appears on the stand or its hardware.
  • Чечим: Clean the rusted areas thoroughly. Apply a rust-inhibiting primer and paint. For long-term prevention, consider replacing standard steel hardware with galvanized or stainless steel fasteners.

7. Техникалык шарттар

ӨзгөчөлүкДеталь
Модель атыGS-380
БрендСенвилл
Продукциянын өлчөмдөрү (L x W x Y)34" W x 15" D x 16" H (86.36 cm x 38.1 cm x 40.64 cm)
Элемент Салмагы14.15 фунт (6.42 кг)
Кубаттуулугу300 фунтка чейин (136 кг)
ШайкештикMost 9000-12000 BTU Mini Split Air Conditioners
МатериалDurable, weather-resistant metal
ТүсOff-White
Ассамблея талап кылынатОоба
ӨзгөчөлүктөрHeavy-Duty, Weather-Resistant Construction, UV Coated, Wide Compatibility Range

8. Кепилдик маалыматы

The Senville GS-380 Mini Split Ground Stand comes with a 90 күндүк кепилдик from the date of purchase. This warranty covers manufacturing defects under normal use. Please retain your proof of purchase for warranty claims. For specific terms and conditions, or to initiate a warranty claim, please contact Senville customer support.

9. Кардарларды колдоо кызматы

For any questions, technical assistance, or support regarding your Senville GS-380 Mini Split Ground Stand, please visit the official Senville website or contact their customer service department. Contact information can typically be found on the product packaging or the Senville brand webсайт.

Senville Official Webсайт: www.senville.com

Тектеш документтер - GS-380

Preview Senville Leto сериясындагы бөлүнгөн типтеги кондиционердин колдонуучунун колдонмосу
This owner's manual provides essential information for the safe installation, operation, maintenance, and troubleshooting of Senville Leto series split-type air conditioners. Learn about unit features, safety guidelines, and how to resolve common issues for optimal performance.
Preview Senville Inverter Split-Type Room Air Conditioner Installation Manual
This installation manual provides essential guidance for the proper setup of Senville Inverter One-Two, One-Three, One-Four, and One-Five split-type room air conditioners. It details safety precautions, installation procedures for various unit types, refrigerant piping, electrical connections, air purging, and testing.
Preview Senville бөлүнгөн типтеги бөлмө кондиционеринин колдонуучунун колдонмосу жана коопсуздук боюнча колдонмосу
Senville бөлүнгөн типтеги бөлмө кондиционерлери үчүн CS019UI-EP(R454B) сыяктуу моделдер үчүн коопсуздук чараларын, иштетүүнү, техникалык тейлөөнү, бузулууларды оңдоону жана орнотуу боюнча көрсөтмөлөрдү камтыган кеңири колдонуучу колдонмосу.
Preview Бөлмөнүн экиге бөлүнгөн кондиционерин орнотуу боюнча колдонмо
Бөлмө кондиционерин орнотуу боюнча кеңири колдонмодо коопсуздук чараларын, имараттын ичиндеги жана сыртындагы блокторду орнотууну, муздаткыч түтүктөрүн, электр туташууларын, абаны эвакуациялоону, газ агып кетүүсүн текшерүүнү, сыноону жана таңгактоо/ачуу процедураларын камтыган.
Preview Senville Wall Mounted Air Conditioner Installation Manual
Comprehensive installation manual for Senville wall-mounted air conditioners, detailing safety precautions, installation locations, dimensions, piping, wiring, and testing procedures.
Preview Senville SL550 мини-бөлүнгөн орнотуу кронштейнин чогултуу боюнча нускамалар
Senville SL550 мини-сплит дубалга орнотуучу кронштейнин чогултуу боюнча деталдуу көрсөтмөлөрү, ал каналсыз кондиционерлер жана жылуулук насостору үчүн иштелип чыккан. Керектүү шаймандарды, жабдуулардын тизмесин жана этап-этабы менен орнотуу боюнча көрсөтмөлөрдү камтыйт.