AMS 405.57

AMS 405.57 1 1/2" x 12" Aluminum Liner User Manual

Model: 405.57 | Brand: AMS

Introduction

This manual provides essential information for the proper use, maintenance, and care of your AMS 405.57 1 1/2" x 12" Aluminum Liner. This liner is designed for use with various 1-1/2" AMS core samplers, facilitating efficient and reliable sample чогултуу.

Продукт бүттүview

AMS 1 1/2 inch by 12 inch aluminum liner

Сүрөттүн сүрөттөлүшү: A single, cylindrical aluminum tube, approximately 12 inches in length, with an outer diameter of 1 1/2 inches. The surface appears brushed or slightly textured, indicative of aluminum material. Both ends are open, showing the hollow interior of the liner. This image illustrates the primary component of the AMS 405.57 product.

The AMS 405.57 Aluminum Liner is a precision-engineered component for soil and sediment sampling. It features a 1-1/2 inch outer diameter and a 12-inch length. The wall thickness is approximately 0.060 inches, providing a balance of durability and lightweight handling. This liner is specifically designed to integrate seamlessly with compatible AMS core sampлер.

Негизги өзгөчөлүктөрү:

Жайгашуу

Before using the aluminum liner, ensure you have the appropriate AMS core sampler that is compatible with a 1-1/2 inch liner. The liner is intended to be inserted into the core sampler barrel to collect and retain soil or sediment samples.

  1. Inspect the Liner: Carefully examine the aluminum liner for any signs of damage, dents, or deformities that could affect its performance or fit within the core sampлер.
  2. Clean the Liner: Ensure the interior and exterior of the liner are clean and free from debris, dirt, or residues from previous uses. Use a soft cloth and mild detergent if necessary, then rinse thoroughly and dry completely.
  3. Prepare Core Sampлер: Refer to your AMS core sampler's manual for specific instructions on preparing it for liner insertion. Ensure the sampler barrel is clean and free of obstructions.
  4. Лайнерди киргизүү: Gently slide the aluminum liner into the designated slot or barrel of your 1-1/2" AMS core sampler. Ensure it seats properly and securely. Do not force the liner, as this could cause damage to either the liner or the sampлер.
  5. Жарактуулугун текшерүү: Once inserted, confirm that the liner is flush and stable within the core sampler, ready for sampлинг операциялары.

Иштөө нускамалары

The aluminum liner functions as a disposable or reusable sleeve within a core sampler to preserve the integrity of collected samples. Its operation is directly tied to the use of the core sampler itself.

  1. Attach Core Sampлер: Assemble your AMS core sampler with the aluminum liner installed, following the sampler's specific instructions.
  2. Perform Sampлинг: Use the core sampler as directed by its manual to collect the desired soil or sediment sample. The liner will fill with the sample as the sampler penetrates the ground.
  3. Retrieve Sampлер: Carefully extract the core sampler from the ground.
  4. Лайнерди алып салуу: Once the core sampler is retrieved, gently remove the aluminum liner containing the sample. This may involve detaching the sampler's cutting tip or other components as per your sampler's design.
  5. Seal Sampле: Эгерде сample is to be transported or stored, cap both ends of the liner immediately to prevent sample loss, contamination, or disturbance. Use appropriate end caps or sealing methods.
  6. Label Liner: Clearly label the liner with all necessary sample identification information (e.g., date, time, location, depth, project ID).

Эскертүү: Always refer to the specific operating instructions of your AMS core sampler for detailed sampling procedures. The aluminum liner is a passive component designed to hold the sample.

Техникалык тейлөө

Proper maintenance extends the life of your aluminum liner, especially if intended for multiple uses, and ensures sample бүтүндүк.

Проблемаларды чечүү

This section addresses common issues that may arise during the use of your aluminum liner.

КөйгөйМүмкүн себепЧечим
Liner does not fit into core sampлер.
  • Incorrect liner size.
  • Liner is dented or deformed.
  • Core sampler barrel is obstructed or damaged.
  • Verify liner dimensions (1 1/2" OD) against sampler specifications.
  • Inspect liner for damage; replace if necessary.
  • Clean and inspect core sampler barrel.
Sample is difficult to extract from liner.
  • Compacted sample.
  • Rough interior surface of liner (due to wear or damage).
  • Ылайыктуу сample extrusion tools.
  • Consider replacing the liner if interior surface is compromised.
Liner gets stuck in core sampлер.
  • Liner or sampler barrel is dirty.
  • Liner is slightly deformed.
  • Excessive force during insertion.
  • Clean both components thoroughly.
  • Inspect liner for subtle deformities; replace if needed.
  • Always insert gently.

Техникалык шарттар

АтрибутДеталь
Модель номери405.57
Сырткы диаметри1 1/2 дюйм (болжол менен 3.81 см)
Узундук12 дюйм (болжол менен 30.48 см)
Дубалдын калыңдыгыApproximately 0.060 inches (approx. 1.52 mm)
МатериалАлюминий
Болжолдуу Салмагы1 фунт (болжол менен 0.45 кг)
Пакеттин өлчөмдөрү14 x 4 x 4 дюйм
ӨндүрүүчүAMS Incorporated
Келип чыккан өлкөАмерика Кошмо Штаттары
Дата биринчи жеткиликтүү12-декабрь, 2017-жыл

Кепилдик жана колдоо

Specific warranty information for the AMS 405.57 Aluminum Liner is not provided in this document. For details regarding product warranty, technical support, or replacement parts, please contact AMS Incorporated directly through their official webсайт же кардарларды тейлөө каналдары.

Өндүрүүчү: AMS Incorporated

Please refer to the manufacturer's official resources for the most current support information.

Тектеш документтер - 405.57

Preview ams AS5600L Adapter Board Eval Kit Manual
This manual provides comprehensive information for the ams AS5600L-WL_EK_AB adapter board, including kit contents, board description, mounting instructions, pinout details, I2C mode operation, hardware schematics, PCB layout, and ordering information.
Preview ams AS5048 14-бит Ротари Position Sensor User Manual
Бул колдонуучу колдонмо ams AS5048, санариптик бурчу жана PWM чыгышы бар 14 биттик айлануучу позиция сенсору жөнүндө толук маалымат берет. Ал AS5048 адаптер тактасын, монтаждоону, пинутту, операциялык кутуларды (SPI, Daisy Chain), микропрограмманы коддоону камтыйт.amples, жана аппараттык схемалар. Бул сенсорду системаларына киргизген инженерлер үчүн өтө маанилүү.
Preview ams AS5048 Adapter Board Evaluation Kit Manual
This manual details the ams AS5048 Adapter Board (AS5048-EK-AB), an evaluation kit for the AS5048 magnetic position sensor. It covers hardware, operation modes (SPI, I2C), software examples, and contact information for ams AG.
Preview ams AS5048 Adapter Board Evaluation Kit Manual
User manual for the ams AS5048 Adapter Board Evaluation Kit (AS5048-EK-AB), detailing its features, pinout, mounting, operation cases (SPI modes), hardware schematics, PCB layout, and contact information.
Preview AMS Wall Clock Operating Instructions
Operating instructions for AMS wall clocks, covering battery installation, replacement, and general usage in multiple languages.
Preview TSL2521 EVM User Guide: Ambient Light Sensor Evaluation Kit
User guide for the ams TSL2521 EVM, detailing its features as a highly sensitive ambient light sensor with selective flicker detection and fast sampling for use behind OLED or auxiliary to camera. Includes hardware and software descriptions, setup, and legal information.