1. Киришүү

This manual provides detailed instructions for the proper setup, operation, and maintenance of the Topcon DT-209 Optical Digital Theodolite. To ensure accurate measurements and prolong the life of your instrument, please read this manual thoroughly before use and keep it for future reference.

2. Продукт бүтүп калдыview

The Topcon DT-209 is an optical digital theodolite designed for precise angle measurements in surveying and construction applications. It features a digital display for clear readings and robust construction for field use.

Topcon DT-209 Digital Theodolite with its carrying case

2.1-сүрөт: Topcon DT-209 Digital Theodolite shown with its protective carrying case. The instrument is positioned in front of the case, highlighting its compact design and the included transport solution.

Фронт view of the Topcon DT-209 Digital Theodolite showing the display and control buttons

2.2-сүрөт: Фронт view of the Topcon DT-209. This image clearly displays the digital screen, control buttons (R/L, HOLD, 0 SET, POWER, CLOCK), and the objective lens, which are essential for operation.

Side view of the Topcon DT-209 Digital Theodolite

2.3-сүрөт: Side view of the Topcon DT-209, illustrating the eyepiece, focusing knob, and horizontal clamp. This perspective provides a view of the instrument's profile and key adjustment components.

3. Орнотуу

  1. Пакеттен чыгаруу: Carefully remove the theodolite from its carrying case. Inspect for any visible damage.
  2. Монтаждоо: Securely attach the theodolite to a stable tripod. Ensure the tripod legs are spread wide and firmly planted on the ground.
  3. Түздөө: Use the circular bubble level and the plate levels to roughly level the instrument. Fine-tune leveling using the foot screws while observing the electronic level display (if available) or the plate levels.
  4. Күйгүзүү: басыңыз КҮЧ аспапты күйгүзүү үчүн баскычты басыңыз.

4. Иштөө нускамалары

4.1. Basic Angle Measurement

  1. Нөл орнотуу: Point the telescope to the initial reference point. Press the 0 SET button to set the horizontal angle to 0°00'00".
  2. Targeting: Rotate the instrument and point the telescope to the target point. Use the tangent screws for fine adjustment.
  3. Окуу: Read the horizontal and vertical angles directly from the digital display.

4.2. Changing Horizontal Angle Mode

басыңыз R/L button to switch between right (clockwise) and left (counter-clockwise) horizontal angle measurement modes.

4.3. Holding a Reading

To hold the current angle reading on the display, press the БЕРҮҮ баскычын басыңыз. Бошотуу үчүн аны кайра басыңыз.

5. Техникалык тейлөө

6. Кыйынчылыктарды

КөйгөйМүмкүн себепЧечим
Аспап күйбөйт.Төмөн же өлүп калган батарейкалар.Батареяларды жаңысына алмаштырыңыз. Туура полярдуулукту камсыз кылыңыз.
Display shows erratic readings.Instrument not properly leveled; environmental interference.Re-level the instrument carefully. Shield from strong vibrations or electromagnetic fields.
Difficulty focusing the telescope.Eyepiece not adjusted for user's vision; object too close/far.Adjust the eyepiece diopter. Ensure the target is within the instrument's focusing range.

7. Техникалык шарттар

ӨзгөчөлүкДеталь
БрендTopcon
МоделDT-209
СтильСанарип
Иштөө режимиManual
ТүсКара
UPC696545805318
Батареялар камтылганбы?Жок
Батареялар керекпи?Жок

8. Кепилдик жана колдоо

Specific warranty information for the Topcon DT-209 Optical Digital Theodolite is not provided within this manual. Please refer to your purchase documentation or contact your authorized Topcon dealer for details regarding warranty coverage and technical support services.

Тектеш документтер - DT-209

Preview Topcon YieldTrakk YM-1 колдонуучусунун колдонмосу: Түшүмдүүлүктү көзөмөлдөө боюнча колдонмо
Topcon YieldTrakk YM-1 түшүмдүүлүктү көзөмөлдөө системасын иштетүү жана техникалык тейлөө боюнча маанилүү маалымат. Айыл чарба колдонмолору үчүн коопсуз колдонууну, орнотууну, башкарууну, коопсуздукту жана техникалык тейлөөнү камтыйт.
Preview Topcon Office v10.0 чыгарылыш эскертүүлөрү - 2025-жылдын сентябрь айы
Topcon Office 10.0 версиясы үчүн 2025-жылдын сентябрь айына карата жаңы функцияларды, жакшыртууларды, системалык талаптарды жана оңдоолорду кеңири баяндаган чыгарылыш эскертүүлөрү. Убакыт чекитине жаңыртууларды камтыйтamping, projections, import/export, property management, area selection, editing tools, surface operations, 3D view, resurfacing, ADAC, and various bug resolutions.
Preview Topcon Tools: Маалыматтарды импорттоо жана жумуш түзүү боюнча колдонмо
Topcon Tools колдонуучулары үчүн кеңири колдонмо, маалыматтарды кантип импорттоо жана жаңы жумуш орундарын түзүү, айрыкча GPS+ конфигурациялары үчүн. Бул документ геодезиялык маалыматтарды башкаруу боюнча этап-этабы менен көрсөтмөлөрдү берет.
Preview Topcon TRU v4.1.0 жана SRU v4.1.0 Release Notes
Topcon TRU v4.1.0 жана SRU v4.1.0 үчүн релиз эскертүүлөрү, анда GNSS микропрограммасы жана позициялоо системалары үчүн жаңы функциялар, жакшыртуулар жана оңдоолор, анын ичинде ар кандай спутниктик топ жылдыздарды колдоо жана аппараттык камсыздоону жакшыртуулар.
Preview TOPCON бекем планшеттик радио жабдуулары боюнча көрсөтмөлөр
Бул документ TOPCON Rugged планшети үчүн маанилүү маалыматты жана көрсөтмөлөрдү берет, анын иштешин, батареянын коопсуздугун, дубалдагы кубаттагычтын коопсуздугун жана Радио жабдууларынын директивасына ылайык жыштык тилкесинин мүнөздөмөлөрүн камтыйт.
Preview Topcon RL-H5A айлануучу лазер: колдонуу боюнча колдонмо
Topcon RL-H5A айлануучу лазеринин иштөөсүн, коопсуздугун, техникалык тейлөөсүн жана мүнөздөмөлөрүн камтыган кеңири колдонуу боюнча колдонмо. Лазердик нивелирлөөчү аспабыңызды кантип колдонууну жана ага кам көрүүнү үйрөнүңүз.