Arista DCS-7050S-64

Arista DCS-7050S-64 Тармактык коммутатордун колдонуучу колдонмосу

Model: DCS-7050S-64

1. Киришүү

This manual provides essential information for the installation, operation, and maintenance of the Arista DCS-7050S-64 network switch. The Arista DCS-7050S-64 is a high-performance, fixed-configuration data center switch designed for demanding network environments, offering high-density 10 Gigabit Ethernet and 40 Gigabit Ethernet connectivity.

Please read this manual thoroughly before operating the device to ensure proper setup and to maximize its performance and longevity.

2. Продукциянын өзгөчөлүктөрү

  • Жогорку тыгыздыктагы байланыш: Features 48 ports of 1/10 Gigabit Ethernet SFP+ and 4 ports of 40 Gigabit Ethernet QSFP+ for flexible network designs.
  • Резервдик кубаттуулук: Equipped with dual 460W AC power supplies for enhanced reliability and continuous operation.
  • Мыкты курулуш: Housed in a durable metal chassis, suitable for rack-mount installations in data center environments.
  • Ар тараптуу шайкештик: Designed to connect with various devices including desktops, laptops, and servers.
  • Өркүндөтүлгөн тармактык мүмкүнчүлүктөр: Supports a wide range of Layer 2 and Layer 3 networking protocols for complex network architectures.

3. Пакеттин мазмуну

Verify that all items listed below are present in your package. If any items are missing or damaged, contact your supplier immediately.

  • Arista DCS-7050S-64 Network Switch
  • Dual 460W AC Power Supplies (pre-installed or separate)
  • Power Cords (quantity may vary by region)
  • Стойкага орнотуу комплекти (кронштейндер жана буроолор)
  • Консолдук кабель (RJ-45тен DB-9га чейин)
Arista DCS-7050S-64 Switch with included accessories

3.1-сүрөт: Arista DCS-7050S-64 switch shown with dual power supplies, power cord, and console cable.

4. Орнотуу жана орнотуу

4.1 Коопсуздук чаралары

  • Ensure the installation environment is clean, dry, and well-ventilated.
  • Зарыл болсо, тиешелүү жеке коргонуу шаймандарын (ЖКК) кийиңиз.
  • Желдетүүчү тешиктерди жаппаңыз.
  • Аппаратты жерге туташтырылган розеткага туташтырыңыз.

4.2 Physical Installation (Rack Mounting)

  1. Attach the provided rack-mount brackets to the sides of the switch using the included screws.
  2. Carefully slide the switch into an available rack unit, ensuring proper alignment.
  3. Secure the switch to the rack using the appropriate rack screws.
Фронт view of Arista DCS-7050S-64 Network Switch

4.1-сүрөт: Front panel of the Arista DCS-7050S-64 switch, showing 48 SFP+ ports and 4 QSFP+ ports.

4.3 Кубат туташтыруу

  1. Ensure the power switches on the power supply units (PSUs) are in the OFF position.
  2. Connect the power cords to the AC inlets on the rear of the switch.
  3. Plug the other end of the power cords into grounded AC power outlets.
  4. Flip the power switches on the PSUs to the ON position. The system will begin its power-on self-test (POST).
Арткы view of Arista DCS-7050S-64 Network Switch with dual power supplies

4.2-сүрөт: Rear panel of the Arista DCS-7050S-64 switch, illustrating the dual 460W AC power supplies and fan modules.

4.4 Network Cabling

  • Connect SFP+ transceivers and fiber optic cables or DAC cables to the 10GbE SFP+ ports.
  • Connect QSFP+ transceivers and fiber optic cables or DAC cables to the 40GbE QSFP+ ports.
  • Ensure all cables are securely seated.

4.5 Initial Configuration (Console Access)

  1. Connect the console cable (RJ-45 to DB-9) from the switch's console port to a serial port on a computer.
  2. Configure your terminal emulation software (e.g., PuTTY, Tera Term) with the following settings:
    • Берүү ылдамдыгы: 9600
    • Маалымат биттери: 8
    • Паритет: Жок
    • Токтоочу биттер: 1
    • Агымды башкаруу: Жок
  3. Power on the switch. The boot process will display messages on your terminal.
  4. Follow the on-screen prompts to perform initial setup, including setting the management IP address and basic network parameters.

5. Иштөө нускамалары

5.1 Күйгүзүү/өчүрүү

  • Күйгүзүү: Ensure power cords are connected and PSU switches are ON. The switch will automatically power on.
  • Өчүрүү: For a graceful shutdown, log into the CLI and issue the appropriate shutdown command. Then, flip the PSU switches to OFF and disconnect power cords. For an emergency shutdown, simply flip the PSU switches to OFF.

5.2 LED көрсөткүчтөрү

The front panel of the switch features various LED indicators to provide status information:

  • Системанын абалы LED: Indicates overall system health (e.g., green for normal, amber for warning, red for critical).
  • Power Supply LEDs: Located on each PSU, indicate power status (e.g., green for operational, off for no power).
  • Порт абалынын диоддору: Each network port has LEDs indicating link status and activity (e.g., solid green for link, blinking green for activity, off for no link).

5.3 Accessing the Command Line Interface (CLI)

The primary method for configuring and managing the Arista DCS-7050S-64 is through its Command Line Interface (CLI). Access can be achieved via:

  • Консол порту: Direct serial connection (as described in Section 4.5).
  • SSH/Telnet: Remote access over the network using the configured management IP address. SSH is recommended for secure access.

Refer to the Arista EOS (Extensible Operating System) documentation for detailed CLI commands and configuration guides.

6. Техникалык тейлөө

6.1 Тазалоо

  • Regularly inspect the switch for dust accumulation, especially around fan inlets and outlets.
  • Сыртын тазалоо үчүн жумшак, кургак чүпүрөктү колдонуңуз. өжөр кир үчүн, бир аз гamp кездемени колдонсо болот, бул түзмөккө суюктуктун кирбешин камсыз кылат.
  • Use compressed air to gently clear dust from ventilation openings. Ensure the switch is powered off before cleaning internal components.

6.2 Микропрограмма жаңыртуулары

Periodically check the Arista Networks website for the latest EOS firmware updates. Keeping the firmware up-to-date ensures optimal performance, security, and access to new features. Follow Arista's official documentation for the correct firmware upgrade procedure.

6.3 Айлана-чөйрөнү коргоо

  • Maintain the operating temperature within the specified range (refer to Section 8. Specifications).
  • Ensure adequate airflow around the switch to prevent overheating.
  • Avoid exposing the switch to excessive humidity or direct sunlight.

7. Кыйынчылыктарды

Бул бөлүмдө сиз кабылышы мүмкүн болгон жалпы маселелерди чечүү жолдору каралган.

7.1 Күч жок

  • Verify that power cords are securely connected to both the switch and the power outlets.
  • Ensure the power switches on the PSUs are in the ON position.
  • Check the power outlets with another device to confirm they are functional.
  • Inspect power cords for any damage.

7.2 Порт байланышынын көйгөйлөрү

  • Ensure the correct transceiver type (SFP+, QSFP+) is used for the port.
  • Verify that the network cable is securely connected at both ends.
  • Check the cable for damage or kinks.
  • Confirm that the connected device is powered on and configured correctly.
  • Check the port status LEDs for indications of link or activity.

7.3 Тармакка туташуу көйгөйлөрү

  • Verify the switch's IP configuration (IP address, subnet mask, gateway).
  • Check routing tables and VLAN configurations if applicable.
  • Ensure firewalls or access control lists (ACLs) are not blocking traffic.
  • Use CLI commands (e.g., show interfaces, ping, traceroute) to diagnose connectivity.

8. Техникалык шарттар

ӨзгөчөлүкСпецификация
МоделDCS-7050S-64
Порттар48x 1/10GbE SFP+, 4x 40GbE QSFP+
Power SuppliesDual 460W AC (Hot-swappable)
Interface TypeSFP, QSFP
ӨндүрүүчүARISTA
Элемент Салмагы20 фунт (9.07 кг)
Иштин материалыМеталл
ТүсБоз
Шайкеш түзмөктөрИш такта, ноутбук, сервер
Иштөө температурасы0°Cден 40°Cге чейин (32°F—104°F)

9. Кепилдик жана колдоо

This product is offered as an Amazon Renewed item. Amazon Renewed products are professionally inspected and tested to work and look like new. They are eligible for replacement or refund under the Amazon жаңыланган кепилдик эгер сиз сатып алууңузга канааттанбасаңыз.

For technical support, please refer to the official Arista Networks documentation and support resources available on their website. For issues related to your Amazon Renewed purchase, please contact Amazon customer service or the seller directly.

Тектеш документтер - DCS-7050S-64

Preview Arista 7050X3 сериясы боюнча суроо-жооп: Жогорку өндүрүмдүү маалымат борборунун Ethernet коммутаторлору
Explore the Arista 7050X3 Series, a range of high-performance data center switches offering flexible connectivity from 10GbE to 100GbE. This Q&A document details various models, key features like MACsec and advanced buffering, and suitability for modern network architectures.
Preview Ариста 클라우드 네트워킹: 스케일링 아웃 데이터센터 네트워크
Arista Networks. 네트워킹 아키텍처의 구축 및 구현에 대한 접근 방식을 상세히 설명합니다. Arista의 스파인-리프 및 스플라인 네트워크 설계, 개방형 표준 및 유연성인 설계 원칙, 그리고 Arista EOS 운영 체제의 이점을 통해 데이터센터의 성능, 홄의 성윥, 확의 최적화하는 방법을 탐구합니다.
Preview Arista 7160 Series Data Center Switch Data Sheet
Detailed data sheet for the Arista 7160 Series Data Center Switches, covering product highlights, overview, software-defined cloud networking features, system specifications, model comparison, physical characteristics, environmental data, and ordering information.
Preview MACsec конфигурациясы жана иштеши боюнча ак кагаз
Бул ак кагазда Arista Networks маалымат борборунун коммутаторлорундагы MACsec (IEEE 802.1AE) конфигурациясы жана иштеши кеңири баяндалган, анын тармактык трафик үчүн күчтүү, линиялык ылдамдыктагы шифрлөөнү камсыз кылуудагы ролуна басым жасалган.
Preview Arista 7280R3 жана 7280R3A Сериялар Маалымат Борборунун которгучтары Ыкчам баштоо колдонмосу
Бул колдонмо Arista Networks 7280R3 жана 7280R3A Series Data Center Switches орнотуу жана баштапкы орнотуу үчүн маанилүү маалыматты камтыйт. Ал каптап туратview, даярдоо, стойкага орнотуу, кабелдик жана негизги конфигурация.
Preview Arista Көп домендик сегменттөө кызматтарын (MSS) жайылтуу боюнча колдонмо
Zero Trust Networking (ZTN) үчүн Arista's Multi-domain Segmentation Services (MSS) орнотуу жана башкаруу боюнча комплекстүү колдонмо. Микропериметрдик сегментацияны кантип ишке ашырууну, коопсуздук саясаттарын конфигурациялоону жана тармактын коопсуздугун жогорулатууну үйрөнүңүз.