1. Киришүү
This manual provides essential instructions for the installation, operation, and maintenance of your APC BR1500MS Uninterruptible Power Supply (UPS). The BR1500MS is designed to protect your electronic equipment from power outages, surges, and spikes, ensuring continuous power and safeguarding your data.
2. Коопсуздук маалыматы
Please read these instructions carefully before installing or operating the UPS. Failure to follow these instructions may result in damage to the unit, injury, or electric shock.
- The UPS contains internal batteries that are not user-serviceable. Refer to qualified service personnel for battery replacement.
- Батареяларды отко таштабаңыз, анткени алар жарылып кетиши мүмкүн.
- Батареяларды ачпаңыз же кыйратпаңыз. Чыгарылган электролит териге жана көзгө зыяндуу.
- Connect the UPS power cable directly to a wall outlet. Do not use extension cords or surge protectors with the UPS input.
- Ensure the UPS is installed in a well-ventilated area, away from direct sunlight, excessive heat, or moisture.
- UPS имараттын ичинде гана колдонууга арналган.
3. Пакеттин мазмуну
Verify that you have received all the following items with your APC BR1500MS UPS:
- APC BR1500MS UPS Unit
- USB байланыш кабели
- Колдонуучунун Колдонмосу (бул документ)
- PowerChute Personal Edition Software CD (or download instructions)
4. Продукт бүтүп калдыview
Familiarize yourself with the components of your APC BR1500MS UPS.

4.1-сүрөт: алдыңкы панел View
This image displays the front of the APC BR1500MS UPS, highlighting its LCD screen, power button, and USB charging ports. The screen shows battery status, load, and estimated runtime.
Алдыңкы панелдин өзгөчөлүктөрү:
- LCD дисплей: Provides real-time status information such as battery charge, load level, estimated runtime, and various operational modes.
- Кубат баскычы: UPSти күйгүзүү же өчүрүү үчүн колдонулат.
- Menu/Scroll Buttons: Navigate through the LCD display options.
- USB Charging Ports (Type-A and Type-C): Provide power for charging mobile devices.

4.2-сүрөт: Арткы панель View
This image shows the rear panel of the APC BR1500MS UPS, detailing the various outlets for battery backup and surge protection, data line protection ports, and the circuit breaker.
Арткы панелдин өзгөчөлүктөрү:
- Батареянын камдык көчүрмөсүн жана чыңалуудан корголгон розеткалар: Provide power from the battery during outages and protect against surges.
- Жалгыз толкундар: Provide surge protection only, without battery backup.
- Data Line Protection (Ethernet/Coaxial): Protects network and cable connections from surges.
- USB байланыш порту: Connects the UPS to a computer for power management software.
- Ажыраткыч: Resettable overload protection.
- Building Wiring Fault Indicator: Illuminates if a wiring problem is detected in the wall outlet.
5. Орнотуу
5.1 Алгачкы жайгаштыруу
Place the UPS on a flat, stable surface in a cool, dry, and well-ventilated indoor area. Avoid placing it near heat sources, direct sunlight, or excessive dust.
5.2 Туташтыргыч жабдуулар
- Connect to Wall Power: Plug the UPS power cord directly into a grounded 3-prong wall outlet. Do not use extension cords or surge protectors.
- Батареяны туташтыруу: The battery may be disconnected for shipping. Refer to the quick start guide or internal instructions to connect the battery terminals if necessary.
- Connect Devices to Battery Backup Outlets: Plug critical equipment such as your computer, monitor, and external hard drives into the Battery Backup & Surge Protected outlets. These outlets provide power during an outage.
- Connect Devices to Surge Only Outlets: Plug non-critical equipment like printers or scanners into the Жөн гана толкун outlets. These outlets provide surge protection but no battery backup.
- Connect Data Lines (Optional): If desired, connect your network cable (Ethernet) or coaxial cable through the respective data line protection ports on the rear panel.
- Connect USB Communication Cable: Connect one end of the USB cable to the UPS USB port and the other end to your computer. This enables communication for the PowerChute software.

Figure 5.1: Typical Desktop Setup
This image illustrates a common setup where the APC BR1500MS UPS is positioned on a desk, providing power and protection to a desktop computer and monitor.
5.3 Баштапкы күйгүзүү
After connecting all equipment, press the power button on the front panel to turn on the UPS. The LCD display will illuminate, and the UPS will begin charging its battery.
6. UPSти иштетүү
6.1 Алдыңкы панелдин дисплейи
The LCD display provides various status indicators. Use the menu buttons to cycle through information such as:
- Киргизүү көлөмүtage
- Output Voltage
- Load Percentage
- Батарея зарядынын деңгээли
- Болжолдуу Runtime
- Окуялар журналы
6.2 Күйгүзүү/өчүрүү
- Күйгүзүү: Press and hold the power button until a beep is heard and the LCD illuminates.
- Өчүрүү: Press and hold the power button until a beep is heard and the LCD turns off.
6.3 Battery Backup Operation
бийлик учурунда уtage, the UPS will automatically switch to battery power, providing continuous power to connected equipment on the battery backup outlets. The LCD will indicate 'On Battery' and display the estimated runtime.
6.4 USB заряддоо порттору
The front panel features USB-A and USB-C charging ports (5V, 3.0A total) for convenient charging of mobile devices, even when the UPS is off (as long as it is connected to wall power).

Figure 6.1: USB Device Charging
This image demonstrates a smartphone being charged via the USB port on the front of the APC BR1500MS UPS, highlighting its utility for mobile devices.
6.5 PowerChute Personal Edition Software
For advanced power management, install the PowerChute Personal Edition software on your computer. This software allows for:
- Safe system shutdown during extended power outages.
- Customizable UPS settings.
- Энергияны пайдалануу мониторинги.
- Diagnostic capabilities.
Download the latest version from the official APC webсайт.
7. Техникалык тейлөө
7.1 Батареяны алмаштыруу
The internal battery typically lasts 3-5 years. When the battery needs replacement, the UPS will indicate a 'Replace Battery' warning on the LCD. Contact APC support or an authorized service center for replacement batteries and instructions. Always use genuine APC replacement batteries.
7.2 Тазалоо
Periodically clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and obstructions.
7.3 Сактоо
If storing the UPS for an extended period, ensure the battery is fully charged, then disconnect it from wall power and store it in a cool, dry place. Recharge the battery every 3-6 months to prevent permanent damage.
8. Кыйынчылыктарды
Жалпы маселелер жана аларды чечүү үчүн төмөнкү таблицага кайрылыңыз.
| Көйгөй | Мүмкүн себеп | Чечим |
|---|---|---|
| UPS күйбөйт | Battery disconnected or low charge; UPS not connected to wall power. | Ensure battery is connected. Plug UPS into a live wall outlet and allow to charge for several hours. |
| UPS beeps continuously or frequently | On battery power; Overload condition; Low battery. | Check if utility power is present. Reduce connected load. Allow battery to charge. |
| 'Replace Battery' indicator | Батареянын иштөө мөөнөтү бүттү. | Contact APC support for a replacement battery. |
| 'Building Wiring Fault' indicator | Wiring problem in the wall outlet (e.g., missing ground, reversed polarity). | Consult a qualified electrician to inspect the building wiring. |
| No power to connected equipment | UPS is off; Circuit breaker tripped; Equipment not plugged into battery backup outlets. | Turn on UPS. Reset circuit breaker. Ensure critical equipment is in battery backup outlets. |
9. Техникалык шарттар
| Өзгөчөлүк | Спецификация |
|---|---|
| Модел | BR1500MS |
| Кубаттуулугу | 1500VA / 900W |
| Киргизүү көлөмүtage | 120V AC |
| Output Voltage (Батареяда) | 120V AC Sine Wave |
| Батарея түрү | Жабылган коргошун кислотасы |
| Адаттагы толуктоо убактысы | 8 сааттан 90%га чейин |
| Соода түйүндөрү | 10 Total (6 Battery Backup & Surge, 4 Surge Only) |
| USB заряддоо порттору | 1x USB-A, 1x USB-C (5V, 3.0A total) |
| Маалымат линиясын коргоо | RJ45 Ethernet, Coaxial |
| Өлчөмдөрү (H x W x D) | 10.24 x 3.94 x 14.49 дюйм (26 x 10 x 36.8 см) |
| Салмагы | 30.9 фунт (14 кг) |
10. Кепилдик маалыматы
APC by Schneider Electric provides a standard warranty for this product. The specific terms and duration of the warranty may vary by region and product type. Please refer to the warranty card included with your product or visit the official APC webтолук кепилдик маалымат алуу үчүн сайт. Кепилдик дооматтар үчүн сатып алганыңыздын далилин сактаңыз.
11. Колдоо
For technical support, troubleshooting assistance, or information on replacement parts, please visit the official APC by Schneider Electric support website or contact their customer service. You can find contact details and online resources at www.apc.com/support.